GENERAL PROCEDURES
Connecting Rod —
Cleaning
CAUTION: Do not use a caustic cleaning solution or damage to connecting rods can
occur.
1. NOTE: The connecting rod large end is a matched set. The connecting rod cap must be
installed on the original connecting rod in the original position. Do not reverse the cap. Parts are
not interchangeable.
Mark and separate the parts and clean with solvent. Clean the oil passages.
SECTION 303-
00: Engine System — General Information 2003 Mustang Workshop Manual Klj . 1 ba
12003 Mustang Workshop Manual
17. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_4464/S3B~us~en~ ...
GENERAL PROCEDURES
Connecting Rod —
Large End Bore
1. Tighten the bolts to specification, then measure the bore in two directions. The difference is the connecting rod bore out-of-round. Verify the out-of- round is within specification.
z Refer to the appropriate section in Group 303 for the procedure.
z If out of specification, install new components as necessary. Refer to the appropriate
section in Group 303 for the procedure.