PINPOINT TEST F: NO OPERATION IN ALL TEMPERATURE
SETTINGS
PINPOINT TEST G: THE BLOWER MOTOR DOES NOT
OPERATE/DOES NOT OPERATE CORRECTLY INSTALL a new A/C
compressor due to low
performance. REFER to
Section 412
- 03 . TEST the
system for normal operation. Test Step Result / Action to Take
F1 CHECK THE TEMPERATURE CONTROL
z
Start the engine and run at idle. Allow the engine to reach
normal operating temperature.
z Place the function selector switch in the NORMAL A/C
position.
z Adjust the temperature control to full warm position, and
physically feel the discharge air temperature at the at the
center panel vents.
z Rotate the temperature control to full cold position, and
physically feel the discharge air temperature at the center
panel vents.
z Does the discharge air temperature vary? Yes
The temperature blend
door is functioning
correctly. RETURN to the
symptom chart.
No
GO to
F2 .
F2 CHECK FOR A BROKEN A/C TEMPERATURE CONTROL
CABLE z
Remove the climate control assembly to gain access to the
control cable head.
z Move the temperature control from full warm to full cold.
z Inspect the cable control head as you move the temperature
control.
z Does the alignment mark on the control head move? Yes
INSTALL a new
evaporator housing.
REFER to
Section 412 -
02 .
No
INSTALL a new
temperature control cable
assembly. REFER to
Section 412 - 04 .
Test Step Result / Action to Take
G1 CHECK FOR VOLTAGE AT C238
z
Disconnect: Blower Motor Jumper C238.
z Key in ON position.
z Turn the blower motor selector to LOW.
z Turn the function selector to FLOOR.
z Check for voltage between C238- 6, circuit 249 (DB/LG) and
C238- 3, circuit 261 (OG/BK). Yes
GO to
G2 .
No
GO to G4 . Klj . 30 ba