Page 1105 of 5883
DLK-516
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
TRUNK LID UNLOCK SWITCH
2. Check voltage between BCM connector and ground.
Is the inspection result normal?
YES >> GO TO 5
NO >> Replace BCM. Refer to XX-XX, "*****"
.
5.CHECK TRUNK ROOM LAMP SWITCH
Refer to DLK-516, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 6
NO >> Replace trunk lamp switch and trunk release solenoid.
6.CHECK INTERMITTENT INCIDENT
Refer to XX-XX, "*****"
.
>> INSPECTION END.
Component InspectionINFOID:0000000001530670
1.CHECK TRUNK LAMP SWITCH
1. Turn ignition switch OFF.
2. Check trunk lamp switch.
Is the inspection result normal?
YES >> INSPECTION END.
ALKIA0755ZZ
Te r m i n a l s
Voltage (V)
(Approx.) (+)
(–)
BCM connector Terminal
M18 10 Ground Battery voltage
ALKIA0764ZZ
Te r m i n a l
Trunk condition Continuity
Trunk lamp switch and trunk release solenoid
13OPEN Yes
CLOSE No
Page 1106 of 5883
TRUNK LID UNLOCK SWITCH
DLK-517
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
NO >> Replace trunk lamp switch and trunk release solenoid.
Page 1107 of 5883
![NISSAN TIIDA 2007 Service Repair Manual DLK-518
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
BACK DOOR OPENER SWITCH
BACK DOOR OPENER SWITCH
DescriptionINFOID:0000000001530671
Sends the back door opening signal to BCM.
Component Func NISSAN TIIDA 2007 Service Repair Manual DLK-518
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
BACK DOOR OPENER SWITCH
BACK DOOR OPENER SWITCH
DescriptionINFOID:0000000001530671
Sends the back door opening signal to BCM.
Component Func](/manual-img/5/57395/w960_57395-1106.png)
DLK-518
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
BACK DOOR OPENER SWITCH
BACK DOOR OPENER SWITCH
DescriptionINFOID:0000000001530671
Sends the back door opening signal to BCM.
Component Function CheckINFOID:0000000001530672
1.CHECK FUNCTION
With CONSULT-III
Check “TR/BD OPNR SW” in “Data Monitor” mode with CONSULT-III.
Is the inspection result normal?
YES >> Back door opener switch is OK.
NO >> Refer to XX-XX, "*****"
.
Diagnosis ProcedureINFOID:0000000001530673
1.CHECK BACK DOOR OPENER SWITCH INPUT SIGNAL
Check voltage between BCM connector and ground.
Is the inspection result normal?
YES >> GO TO 5
NO >> GO TO 2
2.CHECK BACK DOOR OPENER SWITCH CIRCUIT
1. Disconnect BCM and back door opener switch connectors.
Monitor item Condition
TR/BD OPNR SWBack door opener switch is pressed :ON
Back door opener switch is released :OFF
ALKIA0741ZZ
Te r m i n a l s
Condition of back door opener switchVoltage (V)
(Approx.) (+)
(–)
BCM
connectorTe r m i n a l
M18 5 GroundON (press and hold) 0
OFF (release) Battery voltage
Page 1108 of 5883
![NISSAN TIIDA 2007 Service Repair Manual BACK DOOR OPENER SWITCH
DLK-519
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
2. Check continuity between BCM connector (A) M18 terminal 5
and back door opener s NISSAN TIIDA 2007 Service Repair Manual BACK DOOR OPENER SWITCH
DLK-519
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
2. Check continuity between BCM connector (A) M18 terminal 5
and back door opener s](/manual-img/5/57395/w960_57395-1107.png)
BACK DOOR OPENER SWITCH
DLK-519
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
2. Check continuity between BCM connector (A) M18 terminal 5
and back door opener switch connector (B) D408 terminal 1.
3. Check continuity between BCM connector (A) M18 terminal 5 and ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair harness or connector.
3.CHECK BACK DOOR OPENER SWITCH GROUND CIRCUIT
Check continuity between back door opener switch connector and
ground.
Is the inspection result normal?
YES >> GO TO 4
NO >> Repair or replace harness.
4.CHECK BACK DOOR OPENER SWITCH
Refer to DLK-520, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 5
NO >> Replace back door opener switch.
5.CHECK INTERMITTENT INCIDENT
Refer to XX-XX, "*****"
.
>> INSPECTION END.
ALKIA0761ZZ
BCM connector Terminal back door opener switch connector Terminal Continuity
M18 5 D408 1 Yes
BCM connector Terminal
GroundContinuity
M18 5 No
WIIA1187E
back door opener switch Terminal
GroundContinuity
D408 2 Yes
Page 1109 of 5883
DLK-520
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
BACK DOOR OPENER SWITCH
Component Inspection
INFOID:0000000001530674
1.CHECK BACK DOOR OPENER SWITCH
1. Turn ignition switch OFF.
2. Check continuity between back door opener switch terminals.
Is the inspection result normal?
YES >> INSPECTION END.
NO >> Replace back door opener switch.
WIIA1186E
Te r m i n a l
Condition Continuity
Back door opener switch
12ON (press and hold) Yes
OFF (release) No
Page 1110 of 5883
![NISSAN TIIDA 2007 Service Repair Manual TRUNK LID OPENER SWITCH
DLK-521
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
TRUNK LID OPENER SWITCH
DescriptionINFOID:0000000001530675
Transmits trunk lid open NISSAN TIIDA 2007 Service Repair Manual TRUNK LID OPENER SWITCH
DLK-521
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
TRUNK LID OPENER SWITCH
DescriptionINFOID:0000000001530675
Transmits trunk lid open](/manual-img/5/57395/w960_57395-1109.png)
TRUNK LID OPENER SWITCH
DLK-521
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
TRUNK LID OPENER SWITCH
DescriptionINFOID:0000000001530675
Transmits trunk lid open signal to BCM.
Component Function CheckINFOID:0000000001530676
1.CHECK FUNCTION
With CONSULT-III
Check trunk lid opener switch TR/BD OPEN SW in “Data Monitor mode with CONSULT-III.
When trunk lid opener switch is pressed.
Is the inspection result normal?
YES >> Trunk lid opener switch is OK.
NO >> Refer to DLK-521, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001530677
1.CHECK TRUNK LID OPEN INPUT SIGNAL
Check voltage between BCM connector and ground.
Is the inspection result normal?
YES >> GO TO 5
NO >> GO TO 2
2.CHECK TRUNK LID OPENER SWITCH CIRCUIT
1. Disconnect BCM and trunk lid opener switch connectors.
Monitor item Condition
TR/BD OPEN SWTrunk lid opener switch is pressed: ON
Trunk lid opener switch is released: OFF
ALKIA0741ZZ
Te r m i n a l s
Condition of trunk lid opener switchVoltage (V)
(Approx.) (+)
(–)
BCM
connectorTe r m i n a l
M18 5 GroundON (press and hold) 0
OFF (release) Battery voltage
Page 1111 of 5883
![NISSAN TIIDA 2007 Service Repair Manual DLK-522
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
TRUNK LID OPENER SWITCH
2. Check continuity between BCM connector (A) M18 terminal 5
and trunk lid opener switch connector (B) B61 terminal NISSAN TIIDA 2007 Service Repair Manual DLK-522
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
TRUNK LID OPENER SWITCH
2. Check continuity between BCM connector (A) M18 terminal 5
and trunk lid opener switch connector (B) B61 terminal](/manual-img/5/57395/w960_57395-1110.png)
DLK-522
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
TRUNK LID OPENER SWITCH
2. Check continuity between BCM connector (A) M18 terminal 5
and trunk lid opener switch connector (B) B61 terminal 1.
3. Check continuity between BCM connector (A) M18 terminal 5 and ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair harness or connector.
3.CHECK TRUNK LID OPENER SWITCH GROUND CIRCUIT
Check continuity between trunk lid opener switch connector and
ground.
Is the inspection result normal?
YES >> GO TO 4
NO >> Repair or replace harness.
4.CHECK TRUNK LID OPENER SWITCH
Refer to DLK-523, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 5
NO >> Replace trunk lid opener switch.
5.CHECK INTERMITTENT INCIDENT
Refer to XX-XX, "*****"
.
>> INSPECTION END.
ALKIA0761ZZ
BCM connector Terminal Trunk lid opener switch connector Terminal Continuity
M18 5 B61 1 Yes
BCM connector Terminal
GroundContinuity
M18 5 No
WIIA1187E
Trunk lid opener switch Terminal
GroundContinuity
B61 2 Yes
Page 1112 of 5883
TRUNK LID OPENER SWITCH
DLK-523
< COMPONENT DIAGNOSIS >[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
Component InspectionINFOID:0000000001530678
1.CHECK TRUNK LID OPENER SWITCH
1. Turn ignition switch OFF.
2. Check continuity between trunk lid opener switch terminals.
Is the inspection result normal?
YES >> INSPECTION END.
NO >> Replace trunk lid opener switch.
WIIA1186E
Te r m i n a l
Condition Continuity
Trunk lid opener switch
12ON (press and hold) Yes
OFF (release) No