Page 5009 of 5267

4.CHECK (C32) RECIRCULATION DOOR DRIVERCIRCUIT FOR A SHORT TO (C34) COMMON DOOR
DRIVER CIRCUIT
Disconnect the Recirculation Door Actuator harness connector.
Measure the resistance between the (C32) Recirculation Door Driver
circuit and the (C34) Common Door Driver circuit in the A/C Heater
Control C1 harness connector.
Istheresistancebelow10kohms?
Ye s>>
Repair the (C32) Recirculation Door Driver circuit for a short
to the (C34) Common DoorDrivercircuit.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Replace the Recirculation Door Actuator in accordance with
the Service Information.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
5.RUN THE ACTUATOR DTC DETECTION TEST
Reconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
With the scan tool, erase HVAC DTCs.
With the scan tool, select System Tests and then select Actuator DTC Detection. When the test is complete, select
View DTCs.
Does the scan tool only display: B1059–RECIRCULATION DOOR CONTROL CIRCUITLOW?
Ye s>>
Replace the A/C Heater Control in accordance with the Service Information.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).
No, Other DTC(s) Displayed
Diagnose and repair the DTC(s). If multiple DTCs are present, beginning with the passenger blend door,
diagnose and repair all short high DTCs and then all short low DTCs. Refer tothe Table of Contents in
this Section for a complete list of HVAC related symptoms.
No, And No Other DTCs Displayed
Using the wiring diagram as a guide, inspect the wiring and connectors for conditions causing an inter-
mittent short. Repair as necessary.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).
Page 5010 of 5267
B1059–RECIRCULATION DOOR CONTROL CIRCUIT LOW (SINGLE-ZONE)
For a complete wiring diagramRefer to Section 8W.
Page 5011 of 5267

Theory of Operation
The A/C Heater Control drives the Recirculation Door Actuator via the (C32) Recirculation Door Driver circuit and
the (C34) Common Door Driver circuit. All of the door actuators share the (C34) Common Door Driver circuit. Inside
the A/C Heater Control, each door actuator has its own unique driver, but all share a single common door driver
circuit. Due to the shared circuitry similar DTCs can set at the same time for multiple actuators depending upon the
type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C32) Recirculation Door Driver circuit is shorted to ground.
Possible Causes
(C32) RECIRCULATION DOOR DRIVER CIRCUIT SHORTED TO GROUND
(C32) RECIRCULATION DOOR DRIVER CIRCUIT SHORTED TO OTHER DOOR DRIVER CIRCUIT(S)
RECIRCULATION DOOR ACTUATOR
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C32) RECIRCULATION DOOR DRIVER CIRCUIT FOR A SHORT TO GROUND
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Measure the resistance of the (C32) Recirculation Door Driver circuit
between ground and the A/C Heater Control C1 harness connector.
Istheresistancebelow10kohms?
Ye s>>
Repair the (C32) Recirculation Door Driver circuit for a short
to ground.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
Page 5012 of 5267

2.CHECK (C32) RECIRCULATION DOOR DRIVER CIRCUIT FOR A SHORT TO OTHER DOOR DRIVER
CIRCUITS
Measure the resistance between the (C32) Recirculation Door Driver
circuit and the (C61) Blend Door Driver circuit, the (C29) Mode Door 1
Driver circuit, and the (C801) Mode Door 2 Driver circuit in the A/C
Heater Control C1 harness connector.
Is the resistance below 10k ohms between the (C32) Recircula-
tion Door Driver circuit and any of the other door driver cir-
cuits?
Ye s>>
Repair the circuit(s) with a resistance below 10k ohms for a
short to the (C32) Recirculation Door Driver circuit.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 3
3.CHECK RECIRCULATION DOOR ACTUATOR CIRCUIT RESISTANCE
Measure the resistance between the (C32) Recirculation Door Driver
circuit and the (C34) Common Door Driver circuit in the A/C Heater
Control C1 harness connector.
Is the resistance below 30 ohms?
Ye s>>
Go To 4
No>>
Go To 5
Page 5013 of 5267

4.CHECK (C32) RECIRCULATION DOOR DRIVERCIRCUIT FOR A SHORT TO (C34) COMMON DOOR
DRIVER CIRCUIT
Disconnect the Recirculation Door Actuator harness connector.
Measure the resistance between the (C32) Recirculation Door Driver
circuit and the (C34) Common Door Driver circuit in the A/C Heater
Control C1 harness connector.
Istheresistancebelow10kohms?
Ye s>>
Repair the (C32) Recirculation Door Driver circuit for a short
to the (C34) Common DoorDrivercircuit.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Replace the Recirculation Door Actuator in accordance with
the Service Information.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
5.RUN THE ACTUATOR DTC DETECTION TEST
Reconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
With the scan tool, erase HVAC DTCs.
With the scan tool, select System Tests and then select Actuator DTC Detection. When the test is complete, select
View DTCs.
Does the scan tool only display: B1059–RECIRCULATION DOOR CONTROL CIRCUITLOW?
Ye s>>
Replace the A/C Heater Control in accordance with the Service Information.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).
No, Other DTC(s) Displayed
Diagnose and repair the other DTC(s). If multiple DTCs are present, beginning with the common circuit,
diagnose and repair all short high DTCs and then all short low DTCs. Refer tothe Table of Contents in
this Section for a complete list of HVAC related symptoms.
No, And No Other DTCs Displayed
Using the wiring diagram as a guide, inspect the wiring and connectors for conditions causing an inter-
mittent short. Repair as necessary.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).
Page 5014 of 5267
B1060–CLIMATE CONTROL MOTOR(S) COMMON 1 CONTROL CIRCUIT HIGH
(DUAL-ZONE)
Page 5015 of 5267

For a complete wiring diagramRefer to Section 8W.
Theory of Operation
The A/C Heater Control drives the Driver Blend Door Actuator via the (C61) Blend Door Driver circuit and the (C34)
Common Door Driver circuit. The A/C Heater Control drives the Passenger Blend Door Actuator via the (C33) Pas-
senger Blend Door Driver circuit and the (C34) Common Door Driver circuit.The A/C Heater Control drives the
Mode Door 1 (Panel to Floor) Actuator via the (C29) Mode Door 1 Driver circuit and the (C34) Common Door Driver
circuit. The A/C Heater Control drives the Mode Door 2 (Defrost to Floor) Actuator via the (C801) Mode Door 2
Driver circuit and the (C34) Common Door Driver circuit. The A/C Heater Control drives the Recirculation Door
Actuator via the (C32) Recirculation Door Driver circuit and the (C34) Common Door Driver circuit. All of the door
actuators share the (C34) Common Door Driver circuit. Inside the A/C Heater Control, each door actuator has its
own unique driver, but all share a single common door driver circuit. Due tothesharedcircuitrysimilarDTCscan
set at the same time for multiple actuators depending upon the type of short, its location, and the direction the
actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C34) Common Door Driver circuit is shorted to voltage.
Possible Causes
(C34) COMMON DOOR DRIVER CIRCUIT SHORTED TO VOLTAGE
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C34) COMMON DOOR DRIVER CIRCUIT FOR A SHORT TO VOLTAGE
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
Measure the voltage of the (C34) Common Door Driver circuit.
Is the voltage above 0.2 volts?
Ye s>>
Repair the (C34) Common Door Driver circuit for a short to
voltage.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
Page 5016 of 5267

2.RUN THE ACTUATOR DTC DETECTION TEST
Turn the ignition off.
Reconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
With the scan tool in HVAC, select System Tests and then select Actuator DTCDetection. When the test is com-
plete, select View DTCs.
Does the scan tool only display: B1060–CLIMATE CONTROL MOTOR(S) COMMON 1 CONTROL CIRCUIT
HIGH?
Ye s>>
Replace the A/C Heater Control in accordance with the Service Information.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).
No, Other DTC(s) Displayed
Diagnose and repair the other DTC(s). If multiple DTCs are present, beginning with the passenger blend
door, diagnose and repair all short high DTCs and then all short low DTCs. Refer to the Table of Con-
tents in this Section for a complete list of HVAC related symptoms.
No, And No Other DTCs Displayed
Using the wiring diagram as a guide, inspect the wiring and connectors for conditions causing an inter-
mittent short. Repair as necessary.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).