Page 4097 of 5598

PWC-12
< SYSTEM DESCRIPTION >
DIAGNOSIS SYSTEM (BCM)
RETAIND PWR
RETAIND PWR : CONSULT-III Function (BCM - RETAINED PWR)INFOID:0000000006217270
Data monitor
CONSULT screen item Indication/Unit Description
Vehicle Speed km/h Vehicle speed of the moment a particular DTC is detected
Odo/Trip Meter km Total mileage (Odometer value) of the moment a particular DTC is detected
Vehicle Condition SLEEP>LOCK
Power position status of
the moment a particular
DTC is detected While turning BCM status from low power consumption mode to
normal mode (Power supply position is “LOCK”)
SLEEP>OFF While turning BCM status from low power consumption mode to
normal mode (Power supply position is “OFF”.)
LOCK>ACC While turning power supply position from “LOCK” to “ACC”
ACC>ON While turning power supply position from “ACC” to “IGN”
RUN>ACC While turning power supp
ly position from “RUN” to “ACC” (Vehicle
is stopping and selector lever is except P position.)
CRANK>RUN While turning power su
pply position from “CRANKING” to “RUN”
(From cranking up the engine to run it)
RUN>URGENT While turning power supply positi
on from “RUN“ to “ACC” (Emer-
gency stop operation)
ACC>OFF While turning power supply position from “ACC” to “OFF”
OFF>LOCK While turning power supply position from “OFF” to “LOCK”
OFF>ACC While turning power supply position from “OFF” to “ACC”
ON>CRANK While turning power supply position from “IGN” to “CRANKING”
OFF>SLEEP While turning BCM status from normal mode (Power supply posi-
tion is “OFF”.) to low power consumption mode
LOCK>SLEEP While turning BCM status from normal mode (Power supply posi-
tion is “LOCK”.) to low power consumption mode
LOCK Power supply position is “LOCK”
(Ignition switch OFF with steer-
ing is locked.)
OFF Power supply position is “OFF” (Ignition switch OFF with steering
is unlocked.)
ACC Power supply position is “ACC” (Ignition switch ACC)
ON Power supply position is “IGN” (Ignition switch ON with engine
stopped)
ENGINE RUN Power supply position is “RUN” (Ignition switch ON with engine
running)
CRANKING Power supply position is “CRANKING” (At engine cranking)
IGN Counter 0 - 39 The number of times that ignition switch is turned ON after DTC is detected
The number is 0 when a malfunction is detected now.
The number increases like 1
→ 2 → 3...38 → 39 after returning to the normal condition
whenever ignition switch OFF → ON.
The number is fixed to 39 until the self-diagnosis results are erased if it is over 39.
Monitor Item Description
DOOR SW-DR Indicates [ON/OFF] condition of driver side door switch.
DOOR SW-AS Indicates [ON/OFF] condition of passenger side door switch.
Revision: 2010 May2011 QX56
Page 4098 of 5598
BCM (BODY CONTROL MODULE)PWC-13
< ECU DIAGNOSIS INFORMATION >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
ECU DIAGNOSIS INFORMATION
BCM (BODY CONTROL MODULE)
List of ECU ReferenceINFOID:0000000006217271
ECU Reference
BCM BCS-33, "
Reference Value"
BCS-54, "Fail-safe"
BCS-56, "DTCInspectionPriorityChart"
BCS-57, "DTCIndex"
Revision: 2010 May2011 QX56
Page 4099 of 5598

PWC-14
< ECU DIAGNOSIS INFORMATION >
POWER WINDOW MAIN SWITCH
POWER WINDOW MAIN SWITCH
Reference Value INFOID:0000000006217272
TERMINAL LAYOUT
PHYSICAL VALUES
POWER WINDOW MAIN SWITCH
LIIA2455E
Te r m i n a l N o .(wire color) Description
ConditionVoltage [V]
(Approx.)
+ - Signal name Input/
Output
2
(W/B) Ground Encoder ground — — 0
4
(R) Ground Door key cylinder switch
LOCK signal
InputKey position
(Neutral
→Locked) 5
→ 0
6
(W) Ground
Door key cylinder switch UN-
LOCK signal Input
Key position
(Neutral
→Unlocked) 5
→ 0
8
(L) Ground Front driver side power win-
dow motor UP signal
OutputWhen front LH switch in
power window main
switch is
operated UP 12
9
(G/W) Ground Encoder pulse signal 2 Input When power window mo-
tor operates.
10
(Y) Ground Retained power signal Input IGN SW ON 12
Within 45 second after ig-
nition switch is turned to
OFF
12
When driver side or pas-
senger side door is
opened during retained
power operation 0
11
(G) Ground
Front driver side power win-
dow motor DOWN signal OutputWhen front LH switch in
power window main
switch is
operated DOWN 12
JMKIA0070GB
Revision: 2010 May2011 QX56
Page 4100 of 5598

POWER WINDOW MAIN SWITCHPWC-15
< ECU DIAGNOSIS INFORMATION >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
Fail-safeINFOID:0000000006217273
FAIL-SAFE CONTROL
Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control w hen a signal that is out of the specified value is detected
between the fully closed position and the actual position of the glass.
If fail-safe control, the system changes to a non-in itialized condition and the following function do not operate.
Auto-up operation
Anti-pinch function
Retained power function
When fail-safe control is activated, perform initialization procedure to recover. If a malfunction is detected in
power window switch or more, fail-safe control is activated again.
13
(G/Y) Ground Encoder pulse signal 1 Input When power window mo-
tor operates.
14
(V) Ground Power window serial link Input/
Output IGN SW ON or power win-
dow timer operating.
15
(G/R) Ground Encoder power supply Output When ignition switch ON
or power window timer op-
erates.12
17
(B) Ground Ground — — 0
19
(W) Ground Battery power supply Input — 12
Te r m i n a l N o .
(wire color) Description
ConditionVoltage [V]
(Approx.)
+ - Signal name Input/
Output
JMKIA0070GB
JPMIA0013GB
Malfunction Malfunction condition
Pulse sensor malfunction When one pulse signal that is the specified value or more is detected continuously for the specified
time or more, while door glass is being operated UP or DOWN.
Both pulse sensors mal-
function When both pulse signals are not detected continuously for the specified time or more, while door
glass is being operated UP or DOWN.
Pulse direction malfunc-
tion When a pulse signal indicating that window is moving in the opposite direction against the power win-
dow motor is detected for the specified value or more, while door glass is being operated UP or
DOWN.
Glass recognition position
malfunction 1 When the actual door glass position that is out of specified value is detected compared to the door
glass fully closed position memorized in module, while door glass is being operated UP or DOWN.
Glass recognition position
malfunction 2 When pulse count that is out of the door glass full stroke value or more is detected, while door glass
is being operated UP or DOWN.
Revision: 2010 May2011 QX56
Page 4101 of 5598
PWC-16
< ECU DIAGNOSIS INFORMATION >
FRONT POWER WINDOW SWITCH (PASSENGER SIDE)
FRONT POWER WINDOW SWITCH (PASSENGER SIDE)
Reference Value INFOID:0000000006217274
TERMINAL LAYOUT
PHYSICAL VALUES
FRONT POWER WINDOW SWITCH
JMKIA3330ZZ
Te r m i n a l N o .(wire color) Description
ConditionVoltage [V]
(Approx.)
+ - Signal name Input/
Output
3
(W/B) Ground Encoder ground — — 0
4
(G/R) Ground Encoder power supply Output When ignition switch ON or
power window timer operates 12
8
(L) Ground Power window motor
UP signal
OutputWhen power window motor is
operated UP
12
9
(G) Ground
Power window motor
DOWN signal Output
When power window motor is
operated DOWN 12
10
(W) Ground Battery power supply Input — 12
11
(B) Ground Ground — — 0
12
(G/Y) Ground Encoder pulse signal 1 Input
When power window motor
operates
JMKIA0070GB
Revision: 2010 May2011 QX56
Page 4102 of 5598

FRONT POWER WINDOW SWITCH (PASSENGER SIDE)PWC-17
< ECU DIAGNOSIS INFORMATION >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
Fail-safeINFOID:0000000006217275
FAIL-SAFE CONTROL
Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control w hen a signal that is out of the specified value is detected
between the fully closed position and the actual position of the glass.
If fail-safe control, the system changes to a non-in itialized condition and the following function do not operate.
Auto-up operation
Anti-pinch function
Retained power function
When fail-safe control is activated, perform initialization procedure to recover. If a malfunction is detected in
power window switch or more, fail-safe control is activated again.
15
(G/W) Ground Encoder pulse signal 2 Input When power window motor
operates
16
(V) Ground Power window serial link Input/
Output When ignition switch ON or
power window timer operates
Te r m i n a l N o .
(wire color) Description
ConditionVoltage [V]
(Approx.)
+ - Signal name Input/
Output
JMKIA0070GB
JPMIA0013GB
Malfunction Malfunction condition
Pulse sensor malfunction When one pulse signal that is the specified value or more is detected continuously for the specified
time or more, while door glass is being operated UP or DOWN.
Both pulse sensors mal-
function When both pulse signals are not detected continuously for the specified time or more, while door
glass is being operated UP or DOWN.
Pulse direction malfunc-
tion When a pulse signal indicating that window is moving in the opposite direction against the power win-
dow motor is detected for the specified value or more, while door glass is being operated UP or
DOWN.
Glass recognition position
malfunction 1 When the actual door glass position that is out of specified value is detected compared to the door
glass fully closed position memorized in module, while door glass is being operated UP or DOWN.
Glass recognition position
malfunction 2 When pulse count that is out of the door glass full stroke value or more is detected, while door glass
is being operated UP or DOWN.
Revision: 2010 May2011 QX56
Page 4103 of 5598
PWC-18
< ECU DIAGNOSIS INFORMATION >
REAR POWER WINDOW SWITCH LH
REAR POWER WINDOW SWITCH LH
Reference Value INFOID:0000000006217276
TERMINAL LAYOUT
PHYSICAL VALUES
REAR POWER WINDOW SWITCH
JMKIA3330ZZ
Te r m i n a l N o .(wire color) Description
ConditionVoltage [V]
(Approx.)
+ - Signal name Input/
Output
3
(SB) Ground Encoder ground — — 0
4
(LG) Ground Encoder power supply Output When ignition switch ON or pow-
er window timer operates
12
8
(Y) Ground
Power window motor
UP signal Output
When power window motor is
operated UP 12
9
(G) Ground Power window motor
DOWN signal OutputWhen power window motor is
operated DOWN 12
10
(W) Ground Battery power supply Input — 12
11
(B) Ground Ground — — 0
12
(BR) Ground Encoder pulse signal 1 Input When power window motor oper-
ates
JMKIA0070GB
Revision: 2010 May2011 QX56
Page 4104 of 5598

REAR POWER WINDOW SWITCH LHPWC-19
< ECU DIAGNOSIS INFORMATION >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
Fail-safeINFOID:0000000006217277
FAIL-SAFE CONTROL
Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control w hen a signal that is out of the specified value is detected
between the fully closed position and the actual position of the glass.
If fail-safe control, the system changes to a non-in itialized condition and the following function do not operate.
Auto-up operation
Anti-pinch function
Retained power function
When fail-safe control is activated, perform initialization procedure to recover. If a malfunction is detected in
power window switch or more, fail-safe control is activated again.
15
(L) Ground Encoder pulse signal 2 Input When power window motor oper-
ates.
16
(V) Ground Power window serial link Input/
Output When ignition switch ON or pow-
er window timer operates
Te r m i n a l N o .
(wire color) Description
ConditionVoltage [V]
(Approx.)
+ - Signal name Input/
Output
JMKIA0070GB
JPMIA0013GB
Malfunction Malfunction condition
Pulse sensor malfunction When one pulse signal that is the specified value or more is detected continuously for the specified
time or more, while door glass is being operated UP or DOWN.
Both pulse sensors mal-
function When both pulse signals are not detected continuously for the specified time or more, while door
glass is being operated UP or DOWN.
Pulse direction malfunc-
tion When a pulse signal indicating that window is moving in the opposite direction against the power win-
dow motor is detected for the specified value or more, while door glass is being operated UP or
DOWN.
Glass recognition position
malfunction 1 When the actual door glass position that is out of specified value is detected compared to the door
glass fully closed position memorized in module, while door glass is being operated UP or DOWN.
Glass recognition position
malfunction 2 When pulse count that is out of the door glass full stroke value or more is detected, while door glass
is being operated UP or DOWN.
Revision: 2010 May2011 QX56