Page 1177 of 5135
I36144
TRSG±5
A16A15
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1103
AVENSIS REPAIR MANUAL (RM1018E)
INSPECTION PROCEDURE
1 INSPECT AIR CONDITIONING AMPLIFIER(TR ± SG±5)
(a) Remove the A/C amplifier with connectors being con-
nected.
(b) Turn the ignition switch to ON.
(c) Measure the voltage between terminal TR and SG±5 of
A/C amplifier connector at each temperature.
Standard:
1.8 to 2.2 V at 25C (77F)
1.2 to 1.6 V at 40C (104F)
HINT:
As the temperature increases, the voltage decreases.
OK PROCEED TO NEXT CIRCUIT INSPECTION
SHOWN ON PROBLEM SYMPTOMS TABLE
NG
Page 1178 of 5135
I30111
I30156
Resistance (k)
Temperature (C)
05±1104
± DIAGNOSTICSAIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
2 INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR
(a) Remove cooler the thermistor (room temp. sensor).
(b) Measure the resistance between terminal 1 and 2 of cool-
er thermistor (room temp. sensor) connector at each tem-
perature.
Standard:
1,615 to 1,785 at 25C (77F)
HINT:
As the temperature increases, the resistance decreases.
NG REPLACE COOLER (ROOM TEMP. SENSOR)
THERMISTOR
OK
Page 1179 of 5135
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
05±1105
AVENSIS REPAIR MANUAL (RM1018E)
3CHECK HARNESS AND CONNECTOR(COOLER (ROOM TEMP. SENSOR)
THERMISTOR ± A/C AMPLIFIER)
(a)Check for an open or short circuit in harness and connector between terminal TR an\
d SG±5 of A/C
amplifier (See page 01±32).
NG REPAIR OR REPLACE HARNESS ORCONNECTOR
OK
4 READ OUTPUT DTC
(a) Clear the DTCs.
(b) Read the DTC at least 8.5 minutes after turning the ignition switch ON. Standard: Normal codes are output.
MG REPLACE AIR CONDITIONING AMPLIFIER
OK
SYSTEM OK
Page 1180 of 5135
050TM±13
05±1100
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
PROBLEM SYMPTOMS TABLE
If the normal code is displayed during DTC check although the problem still occurs, check the circuits for
each problem symptom in the order given in the table below, and proceed to the relevant troubleshooting.
SymptomSuspect AreaSee page
Whole functions of the A/C system does not operate.
1. IG power source circuit
2. A/C amplifier assy
3. Engine ECU 1AZ±FSE: 1AZ±FE:
1ZZ±FE/3ZZ±FE:
1CD±FTV:05±1144
05±1098 05±294
05±149 05±5
05±528
Air Flow Control : No blower operation
1. Blower motor circuit
2. Heater relay circuit
3. Blower w/fan motor sub±assy
4. A/C amplifier assy05±1148
05±1146
05±1148
05±1098
Air Flow Control : No blower control1. Blower motor circuit05±1148
Air Flow Control : Insufficient air out
1. Blower w/fan motor sub±assy
2. Blower motor circuit
3. A/C amplifier assy05±1148
05±1148
05±1098
Temperature Control : Cool air does not come out
1. Volume of refrigerant
2. Drive belt tension
3. Refrigerant pressure
4. Air conditioner magnetic valve circut
5. Pressure sensor circuit
6. Air mix control servomotor circuit
7. Air mix damper position sensor circuit
8. Room temp. sensor circuit
9. Ambient temp. sensor circuit
10.A/C amplifier assy55±24
55±46
55±24
05±1151 05±1116
05±1133
05±1122
05±1102
05±1106
05±1098
Temperature Control : Warm air does not come out
1. Air mix control servomotor circuit
2. Air mix damper position sensor circuit
3. Ambient temp. sensor circuit
4. Room temp. sensor circuit
5. A/C amplifier assy
6. Heater radiator05±1133
05±1122
05±1106
05±1102
05±1098
±
Temperature Control : Output air is warmer or cooler than the set
temperature or response is slow.
1. Room temp. sensor circuit
2. Ambient temp. sensor circuit
3. Solar sensor circuit
4. Air mix damper position sensor circuit
5. Air mix control servomotor circuit
6. Evaporator temp. sensor circuit
7. A/C amplifier assy05±1102
05±110605±1113
05±1122
05±1133
05±1109
05±1098
Temperature Control : No temperature control (only Max. cool or Max. warm)
1. Room temp. sensor circuit
2. Ambient temp. sensor circuit
3. Solar sensor circuit
4. Air mix damper position sensor circuit
5. Air mix control servomotor circuit
6. Evaporator temp. sensor circuit
7. A/C amplifier assy05±1102
05±1106
05±1113
05±1122
05±1133
05±1109
05±1098
No air inlet control1. Recirculation damper servomotor circuit
2. A/C amplifier assy05±1153
05±1098
No air outlet control
1. Air outlet damper position sensor circuit
2. Air outlet control servomotor circuit
3. A/C amplifier assy05±1126
05±1136
05±1098
Page 1181 of 5135
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
05±1101
AVENSIS REPAIR MANUAL (RM1018E)
Engine idle up does not occur, or is continuous
1. Air conditioner magnetic valve circut
2. A/C amplifier assy
3. Engine ECU 1AZ±FSE:
1AZ±FE:
1ZZ±FE/3ZZ±FE:
1CD±FTV:05±1151
05±1098 05±294
05±149 05±5
05±528
Set temperature value displayed does not much up with operation
of temperature control switch.1. Air conditioner magnetic valve circut
2. A/C amplifier assy05±1151
05±1098
Brightness does not change when light control switch it turned.1. Illumination light system
2. A/C amplifier assy±
05±1098
Unable to access the diagnosis mode.1. A/C amplifier assy05±1098
DTC is not recorded. Set mode is cleared when IG switch is
turned off.1. Back±up power source circuit
2. A/C amplifier assy05±1142
05±1098
Hot gas heater:
SymptomSuspect AreaSee page
Warm wind does not blow out even if the gas heater switch is
turned on before the water temperature rises under the condition
where the ordinal A/C correctly operates.1. Hot gas heater magnetic valve circuit
2. Hot gas heater switch circuit
3. A/C amplifier assy05±1157
05±1159
05±1098
Page 1182 of 5135
05C7K±01
I36145
A15A16
1211
2423 19 1615
20191817161514131211 8 7 6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1 10 9
2221 1817 141320 05±1098
± DIAGNOSTICSAIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
TERMINALS OF ECU
1. AIR CONDITIONER AMPLIFIER ASSY
Terminal No. (Symbols)Wiring ColorConditionSpecification
A16±5 (BLW) ±
A16±13 (GND)R ± W±BIG SW: ON
Front blower: OperatePulse generation
A16±7 (PRE) ±
A16±18 (SG)L±W ± G±W
Start engine
Refrigerant pressure: 0 kPa (0 kgf/cm2, 0 psi) 3,138 MPa
(32.0 kgf/cm2, 455 psi)
0.5 4.8 V
A15±20 (MPX±) ±
A16±13 (GND)P ± W±BMultiplex communication circuit±
A15±10 (MPX+) ±
A16±13 (GND)P±B ± W±BMultiplex communication circuit±
A15±6 (FRS) ±
A16±13 (GND)P±B ± W±BIG SW: ON
R/F SW: RECIRCULATION FRESH10 to 14 Below 1.0 V
A15±5 (REC) ±
A16±13 (GND)R±Y ± W±BIG SW: ON
R/F SW: FRESH RECIRCULATION10 to 14 Below 1.0 V
A16±17 (HR) ±
A16±13 (GND)GR±R ± W±BIG SW: ON
Front blower: OFF Operate10 to 14 Below 1.0 V
A15±4 (AOF) ±
A16±13(GND)L±B ± W±BIG SW: ON
Mode switch: DEF. FACEBelow 1.0 10 to 14 V
A15±3 (AOD) ±
A16±13 (GND)LG±B ± W±BIG SW: ON
Mode switch: FACE DEF.Below 1.0 10 to 14 V
A16±12 (IG) ±
A16±13 (GND)R±W ± W±BIG SW: LOCK ONBelow 10 to 14 V
A15±2 (AMPH) ±
A16±13 (GND)W ± W±BIG SW: ON
Set passenger side temp.: MAX. COOL MAX. HOTBelow 1.0 10 to 14 V
A15±1 (AMPC) ±
A16±13 (GND)Y ± W±BIG SW:
Set passenger side temp.: MAX HOT MAX. COOLBelow 1.0 10 to 14 V
A15±12 (AMDH) ±
A16±13 (GND)P±L ± W±BIG SW:
Set driver side temp.: MAX. COOL MAX. HOTBelow 1.0 10 to 14 V
A15±11 (AMDC) ±
A16±13 (GND)B ± W±BIG SW:
Set driver side temp.: MAX HOT MAX. COOLBelow 1.0 10 to 14 V
A16±13 (GND) ±
Body groundW±B ± Body groundAlwaysContinuity
A16±24 (+B) ±
A16±13 (GND)W±R ± W±BAlways10 to 14 V
A16±8 (TPD) ±
A15±14 (SG±2)GR ± Y±RIG SW: ON
Set driver side temp.: MAX HOT MAX. COOL1.0 4.0 V
A16±20 TPP ±
A15±13 (SG±1)V ± PIG SW: ON
Set passenger side temp.: MAX HOT MAX. COOL1.0 4.0 V
A16±9 (TSD) ±
A16±13 (GND)LG ± W±BIG SW: ON
Solar sensor subject to electric light0.8 to 3.3 V
A16±21 (TSP) ±
A16±13 (GND)L ± W±BIG SW: ON
Solar sensor subject to electric light0.8 to 3.3 V
Page 1183 of 5135
I35419
A10A9
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1099
AVENSIS REPAIR MANUAL (RM1018E)Terminal No. (Symbols)Specification Condition Wiring Color
A16±22 (TR) ±
A16±6 (SG±5)GR ± GIG SW: ON
Cabin temp.: 25C (77F) 40C (104F)1.8 to 2.2 1.2 to 1.6 V
A16±10 (TE) ±
A15±16 (SG±4)B ± W±GEvaporator temp.: 0C (32F) 15C (59F)2.0 to 2.4 1.4 to 1.8 V
A16±23 (ILL+) ±
A16±13 (GND)G ± W±BLight control switch TAIL or HEAD10 to 14 V
A16±19 (TPM) ±
A15±15 (SG±3)GR±R ± G±WIG SW: ON
Set air flow setting: DEF. FACE1.0 4.0 V
A15±8 (SOL+) ±
A16±13 (GND)R ± W±BStart engine
Compressor: OperatePulse generation
A15±7 (MGV) ±
A16±13 (GND) (*1)R±Y ± W±BStart engine
Hot gas heater: Operate10 to 14 Below 1.0 V
A16±11 (HOTGASIN) ±
A16±13 (GND) (*1)G±Y ± W±BIG SW: ON
Hot Gas SW: ON10 to 14 V
A16±16 (S5) ±
A16±18 (SG)B±W ± G±WIG SW: LOCK ON0 5.0 V
A16±1 (S5±1) ±
A15±13 (SG±1)R ± PIG SW: LOCK ON0 5.0 V
A16±2 (S5±2) ±
A15±14 (SG±2)Y±B ± Y±RIG SW: LOCK ON0 5.0 V
A16±14 (S5±3) ±
A15±15 (SG±3)BR±W ± G±WIG SW: LOCK ON0 5.0 V
A16±15 (S5±4) ±
A16±9 (TSD)O ± LGIG SW: LOCK ON1.7 4.2 V
A16±15 (S5±4) ±
A16±21 (TSP)O ± LIG SW: LOCK ON1.7 4.2 V
A15±17 (CFAN) ±
A16±13 (GND)W±R ± W±BStart engine
Condenser fan: operate10 to 14 Below 1.0 V
A16±19 (PBKIG) ±
A17±13 (GND)B±W ± W±BIG SW: ON
PARKING BRAKE SW: OFF ON10 to 14 Below 1.0 V
A17±3 (PBLT) ±
A17±13 (GND) (*3)L±R ± W±BIG SW: ON
SEAT BELT SIGNAL: OFF ON10 to 14 Below 1.0 V
A17±4 (RDEFIN) ±
A17±13 (GND) (*2)G±W ± W±BIG SW: ON
RDEF RELAY : OFF ONBelow 1.0 10 to 14 V
(*1) Diesel (standard) only
(*2) Petrol only
(*3) Except 1AZ±FE
2. COMBINATION METER
Terminal No. (Symbols)Wiring ColorConditionSpecification
C10±17 (Z1H) ±
Body groundW±B ± Body groundAlwaysContinuity
C10±11 (HAY) ±
C10±12 (HAZ)W±R ± WIG SW: ON
Ambient temp.: 25C (77F) 40C (104F)1.35 to 1.75
0.85 to 1.25 V
Page 1184 of 5135
05C7J±01
I35352
w/ Pulley Compressor Assy
Air Conditioner Magnetic Valve
Pressure Sensor Magnetic Valve Assy
Heater Switch Cooler (Solar Sensor) Thermistor
Combination Meter Assy
Engine and ECT ECU (A/T)
Engine ECU (M/T)
Air Conditioner Control Assy
Cooler (Room Temp. Sensor) Thermistor
DLC3Driver
Side J/B
w/ Hot Gas Heater Models:
(Air Conditioning Amplifier)
Pressure
Sensor
Outer Ambient Temperature Sensor
w/ Receiver Condenser Assy
05±1096
± DIAGNOSTICSAIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
LOCATION