Page 105 of 5135

02±38
± PREPARATIONAUTOMATIC TRANSMISSION / TRANS
AVENSIS REPAIR MANUAL (RM1018E)
(09726±02041)ReplacerFRONT DIFFERENTIAL OIL
SEAL(U341E)
09930±00010Drive Shaft Nut ChiselAUTOMATIC TRANSAXLE
ASSY(U241E)
AUTOMATIC TRANSAXLE
ASSY(U341E)
FRONT DIFFERENTIAL OIL
SEAL(U341E)
09950±70010Handle SetFRONT DIFFERENTIAL OIL
SEAL(U241E)
FRONT DIFFERENTIAL OIL
SEAL(U341E)
(09951±07150)Handle 150FRONT DIFFERENTIAL OIL
SEAL(U241E)
(09951±07200)Handle 200FRONT DIFFERENTIAL OIL
SEAL(U341E)
Recomended Tools
09011±12301Socket Wrench 30 mmAUTOMATIC TRANSAXLE
ASSY(U241E)
AUTOMATIC TRANSAXLE
ASSY(U341E)
FRONT DIFFERENTIAL OIL
SEAL(U341E)
09040±00011Hexagon Wrench SetAUTOMATIC TRANSAXLE
ASSY(U241E)
TRANSMISSION WIRE(U241E)
TRANSMISSION VALVE BODY
ASSY(U241E)
FRONT DIFFERENTIAL OIL
SEAL(U241E)
AUTOMATIC TRANSAXLE
ASSY(U341E)
(09043±20100)Socket Hexagon Wrench 10AUTOMATIC TRANSAXLE
ASSY(U241E)
TRANSMISSION WIRE(U241E)
TRANSMISSION VALVE BODY
ASSY(U241E)
FRONT DIFFERENTIAL OIL
SEAL(U241E)
AUTOMATIC TRANSAXLE
ASSY(U341E)
TRANSMISSION VALVE BODY
ASSY(U341E)
TRANSMISSION WIRE(U341E)
FRONT DIFFERENTIAL OIL
SEAL(U341E)
09042±00010Torx Socket T30TRANSMISSION CONTROL CABLE
ASSY
Page 106 of 5135

± PREPARATIONAUTOMATIC TRANSMISSION / TRANS
02±39
AVENSIS REPAIR MANUAL (RM1018E)
09090±04020Engine Sling DeviceAUTOMATIC TRANSAXLE
ASSY(U241E)
AUTOMATIC TRANSAXLE
ASSY(U341E)
95416±00140Gas Leak Detector
(Halogen Leak Detector)
(DENSO Part No.)TRANSMISSION CONTROL CABLE
ASSY
09216±00021Belt Tension GaugeAUTOMATIC TRANSAXLE
ASSY(U151E/U151F)
SSM
08833±00080Adhesive 1344
THREE BOND 1344
LOCTITE 242 or equivalentTRANSMISSION WIRE(U241E)
TRANSMISSION VALVE BODY
ASSY(U241E)
Equipment
Straight edgeAutomatic transaxle assy
Torque wrench
Vernier calipersAutomatic transaxle assy
Dial indicator with magnetic baseTorque converter and drive plate
Slide calipersAutomatic transaxle assy
Chain blockAutomatic transaxle assy
Lubricant
U341E
Automatic transaxle fluid
Dry fill
Drain and refill
6.9 liter (7.7 USqts, 6.4 lmp.qts)
3.0 liter (3.2 USqts, 2.6 lmp.qts)ATF type T±IV
U241F
Automatic transaxle fluid
Dry fill
Drain and refill
8.6 liter (9.0 USqts, 7.6 lmp.qts)
3.5 liter (3.7 USqts, 3.1 lmp.qts)ATF type T±IV
Page 107 of 5135
031H5±01
± SERVICE SPECIFICATIONSLUBRICATION
03±27
AVENSIS REPAIR MANUAL (RM1018E)
LUBRICATION
SERVICE DATA
1ZZ±FE/3ZZ±FE:
Oil pressure at idle speed
at 3,000 r/min29 kPa (0.3 kgfcm2, 4.2 psi) or more
294 to 539 kPa (3.0 to 5.5 kgfcm2, 43 to 78 psi) or more
AdhesivePart No. 08833 ± 00080, THREE BOND 1344, LOCTITE 242, or
equivalent
1AZ±FE:
Oil pressure at idle speed
at 3,000 rpm29 kPa (0.3 kgfcm2, 4.3 psi) or more
245 to 539 kPa (2.5 to 5.5 kgfcm2, 36 to 78 psi) or more
AdhesivePart No. 08833 ± 00080, THREE BOND 1344, LOCTITE 242, or
equivalent
1AZ±FSE:
Oil pressure at idle speed
at 3,000 rpm29 kPa (0.3 kgfcm2, 4.3 psi) or more
245 to 539 kPa (2.5 to 5.5 kgfcm2, 36 to 78 psi) or more
AdhesivePart No. 08833 ± 00080, THREE BOND 1344, LOCTITE 242, or
equivalent
1CD±FTV:
Oil pressure at idle speed
at 4,500 rpm29 kPa (0.3 kgfcm2, 4.3 psi) or more
245 ± 588 kPa (2.5 ± 6.0 kgfcm2, 36 ± 85 psi)
AdhesivePart No. 08833 ± 00080, THREE BOND 1344, LOCTITE 242, or
equivalent
Page 108 of 5135

031H4±01
03±26
± SERVICE SPECIFICATIONSCOOLING
AVENSIS REPAIR MANUAL (RM1018E)
TORQUE SPECIFICATION
1ZZ±FE/3ZZ±FE:
Part TightenedNmkgfcmftlbf
Radiator drain plug131309
Water pump x Cylinder block Bolt A
Bolt B9.0
1192
11 38.0 in.lbf
8
Water inlet x Cylinder block sub±assy1111 28
Radiator x Radiator support upper1919414
1AZ±FE:
Part TightenedNmkgfcmftlbf
Water pump x Cylinder block9.09280 in.lbf
Water pump x Water pump pulley2626519
Water inlet x Cylinder block9.09280 in.lbf
Radiator support upper x body1919414
1AZ±FSE:
Part TightenedNmkgfcmftlbf
Water pump x Cylinder block9.09280 in.lbf
Water pump x Water pump pulley2626519
Water inlet x Cylinder block9.09280 in.lbf
Radiator support upper x body1919414
1CD±FTV:
Part TightenedNmkgfcmftlbf
Drain plug1313310
Water pump x Cylinder block3132023
Fuel inlet pipe sub±assy x Common rail assy
Used pipe using SST
Used pipe not using SST
New pipe using SST
New pipe not using SST
42
46
31
34428
469
316
34731
34
23
25
Fuel inlet pipe sub±assy x Injection pump
Used pipe using SST
Used pipe not using SST
New pipe using SST
New pipe not using SST
42
46
31
34428
469
316
34731
34
23
25
Engine cover No. 1 x Cylinder head cover sub±assy8.08271 in.lbf
Engine cover No. 1 x Intake manifold8.08271 in.lbf
Timing belt idler Sub±assy No.1 x Cylinder block3535726
Water inlet x Cylinder block8.89078 in.lbf
Radiator reserve tank assy x Radiator assy6.06153 in.lbf
Fan assy w/ motor x Fan shroud assy7.57666 in.lbf
Upper support x Body1919414
Relay box x Radiator assy5.35447 in.lbf
Front wheel1031,05076
Page 109 of 5135

031H3±01
03±24
± SERVICE SPECIFICATIONSCOOLING
AVENSIS REPAIR MANUAL (RM1018E)
COOLING
SERVICE DATA
1ZZ±FE/3ZZ±FE:
Thermostat
Valve opening temperature
Valve lift at 95C (203F)
86 to 90C (187 to 198F)
10 mm (0.394 in.) or more
Radiator cap sub±assy
Standard opening pressure
Minimum opening pressure
74 to 103 kPa (0.75 to 1.05 kgf/cm2, 10.7 to 14.9 psi)
59 kPa (0.6 kgf/cm2, 8.6 psi)
Cooling fan
Standard amperage at 20C (68F)
8 to 12 A
Cooling fan relay
Specified condition Between terminals 1 and 2
Between terminals 3 and 5
Cooling fan relay No.2
Specified condition Between terminals 1 and 2
Between terminals 3 and 4
Between terminals 3 and 5
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
1AZ±FE:
Thermostat
Valve opening temperature
Valve lift at 95C (203F)
80 to 84C (176 to 183F)
10 mm (0.394 in.) or more
Radiator cap sub±assy
Standard opening pressure
Minimum opening pressure
93 ± 122 kPa (0.95 ± 1.25 kgf/cm2, 13.4 ± 17.6 psi)
78 kPa (0.8 kgf/cm2, 11.2 psi)
Cooling fan
Standard amperage at 20C (68F)
Standard amperage (No.2 (With Air Conditioner)) at 20C (68F)
5.2 to 8.2 A (M/T) 8.3 to 11.3 (A/T)
5.2 to 8.2 A (M/T) 8.3 to 11.3 (A/T)
Cooling fan relay
Specified condition Between terminals 1 and 2
Between terminals 3 and 5
Cooling fan relay No.2
Specified condition Between terminals 1 and 2
Between terminals 3 and 4
Between terminals 3 and 5
Cooling fan relay No.3
Specified condition Between terminals 1 and 2
Between terminals 3 and 5
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
1AZ±FSE:
Thermostat
Valve opening temperature
Valve lift at 95C (203F)
86 to 90C (187 to 198F)
10 mm (0.394 in.) or more
Radiator cap sub±assy
Standard opening pressure
Minimum opening pressure
74 to 103 kPa (0.75 to 1.05 kgf/cm2, 10.7 to 14.9 psi)
59 kPa (0.6 kgf/cm2, 8.5 psi)
Page 110 of 5135

± SERVICE SPECIFICATIONSCOOLING
03±25
AVENSIS REPAIR MANUAL (RM1018E) Cooling fan
Standard amperage at 20C (68F)
Standard amperage (No.2 (With Air Conditioner)) at 20C (68F)
5.2 to 8.2 A (M/T) 8.3 to 11.3 (A/T)
5.2 to 8.2 A (M/T) 8.3 to 11.3 (A/T)
Cooling fan relay
Specified condition Between terminals 1 and 2
Between terminals 3 and 5
Cooling fan relay No.2
Specified condition Between terminals 1 and 2
Between terminals 3 and 4
Between terminals 3 and 5
Cooling fan relay No.3
Specified condition Between terminals 1 and 2
Between terminals 3 and 5
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
1CD±FTV:
Thermostat
Valve opening temperature
Valve lift at 95C (203F)
80 ± 84C (176 ± 183F)
8.5 mm (0.33 in.) or more
Radiator cap sub±assy
Standard opening pressure
Minimum opening pressure
93 ± 122 kPa (0.95 ± 1.25 kgf/cm2, 13.4 ± 17.6 psi)
78 kPa (0.8 kgf/cm2, 11.4 psi)
Cooling fan
Standard amperage at 20C (68F)
13.2 A
Cooling fan relay
Specified condition Between terminals 1 and 2
Between terminals 3 and 5
Cooling fan relay No.2
Specified condition Between terminals 1 and 2
Between terminals 3 and 4
Between terminals 3 and 5
Cooling fan relay No.3
Specified condition Between terminals 1 and 2
Between terminals 3 and 5
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Page 111 of 5135
031E3±02
± SERVICE SPECIFICATIONSEXHAUST
03±23
AVENSIS REPAIR MANUAL (RM1018E)
TORQUE SPECIFICATION
1ZZ±FE/3ZZ±FE:
Part TightenedNmkgfcmftlbf
Exhaust pipe assy front x Exhaust manifold4344032
Exhaust pipe assy front x Exhaust pipe assy tail4344032
Heated oxygen sensor x Exhaust pipe assy front4444933
Floor panel brace front x Body3030222
1AZ±FE/1AZ±FSE:
Part TightenedNmkgfcmftlbf
Exhaust pipe assy front x Exhaust manifold4344032
Exhaust pipe assy center x Exhaust pipe assy front4344032
Exhaust pipe assy tail x Exhaust pipe assy center4344032
Floor panel brace front x Body3030222
1CD±FTV:
Part TightenedNmkgfcmftlbf
Exhaust pipe assy front x Exhaust manifold4344032
Exhaust pipe assy front x Tail pipe assy4344032
Floor panel brace front x Body3030222
Page 112 of 5135
031E2±02
03±22
± SERVICE SPECIFICATIONSEXHAUST
AVENSIS REPAIR MANUAL (RM1018E)
EXHAUST
SERVICE DATA
1ZZ±FE/3ZZ±FE:
Compression spring
Free length Minimum Front x Manifold
Front x Tail
41.5 mm (1.634 in.)
38.5 mm (1.516 in.)
1AZ±FE/1AZ±FSE:
Compression spring
Free length Minimum Front x Manifold
Center x Tail
41.5 mm (1.634 in.)
38.5 mm (1.516 in.)
1CD±FTV:
Compression spring
Minimum length Exhaust pipe assy front x Exhaust manifold
41.5mm (1.634 in)
Compression spring
Minimum length Exhaust pipe assy front x Tail pipe assy
38.5mm (1.515 in)