Page 3305 of 5135
73094±02
±
THEFT DETERRENT & DOOR LOCK FUEL LID OPENER SYSTEM
73±29
AVENSIS REPAIR MANUAL (RM1018E)
PROBLEM SYMPTOMS TABLE
SymptomSuspected AreaSee Page
Fuel lid opener does not operate.
1. FUEL OPN fuse
2. Fuel lid opener switch
3. Fuel lid lock control assy
4. Wire harness68±1
73±30
73±30
Page 3306 of 5135
73093±02
73±28
± THEFT DETERRENT & DOOR LOCKFUEL LID OPENER SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
ON±VEHICLE INSPECTION
1. CHECK FUEL LID OPENER OPERATION
(a) Check the basic function.
(1) Check that the fuel lid opens by pressing the fuel lid opener switch.
Page 3307 of 5135
73092±02
B68827
Fuel Lid Lock Control Assy
Fuel Lid Opener Switch
± THEFT DETERRENT & DOOR LOCKFUEL LID OPENER SYSTEM
73±27
AVENSIS REPAIR MANUAL (RM1018E)
FUEL LID OPENER SYSTEM
LOCATION
Page 3308 of 5135
730GU±01
73±26
± THEFT DETERRENT & DOOR LOCKKEY REMINDER WARNING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
KEY REMINDER WARNING SYSTEM
ON±VEHICLE INSPECTION
1. FUNCTION CHECK
(a) Check that the key reminder warning buzzer sounds.
(1) With the driver side door closed, insert the key into the ignition switch lock cylinder, and then turn
the key to LOCK.
(2) Then, check that the buzzer sounds intermittently when the driver side door is opened.
(b) Check that the key reminder warning buzzer stops.
(1) Check that the buzzer stops sounding when any of the following operations is done while the
buzzer is sounding.
Close the driver side door (front door courtesy lamp switch assy is off).
Turn the ignition switch ON.
Pull out the key from the ignition switch lock cylinder.
Page 3309 of 5135

730EY±02
± THEFT DETERRENT & DOOR LOCKTRANSMITTER SUB±ASSY MODULE SET DOOR
CONTROL73±21
AVENSIS REPAIR MANUAL (RM1018E)
REGISTRATION
1. REGISTER RECOGNITION CODE
HINT:
Register the recognition code when replacing the door control transmitter or the door control receiverr.
The add mode is used to register new recognition codes while still retaining codes already registered.
This mode is used when a new transmitter is added. If the number of registered codes exceeds 4, the
previously registered codes will be erased in order, starting from the first registered code.
The rewrite mode is used to erase all the previously registered recognition codes in order to register
new recognition codes. This mode is used when the transmitter or the door control receiver is ex-
changed for a new one.
The confirmation mode is used to confirm how many recognition codes have already been registered
before an additional registration of a recognition codes.
The all clear mode is used to erase all the registered codes and disables the wireless door lock func-
tion. This mode is used when the transmitter is lost.
All the following registration procedures must be performed in order continuously.
Page 3310 of 5135
Within 5 sec.
Within 40 sec.
Continued on next page 1.
2.
3.
4.
5.
6.Insert key into ignition key cylinder, then pull it out.
Close and open driver side door twice.
Close and open driver side door twice.
Insert key into ignition key cylinder and close all doors.
START
Insert key into ignition key cylinder, then pull it out.
Insert key into ignition key cylinder, then pull it out.
Flow Chart of Recognition Code Registration
Within 40 sec.
Within 40 sec.Make sure that the following conditions are met.
No key in ignition key cylinder.
Driver side door is open (Other doors are closed).
Driver side door is unlocked. 73±22
± THEFT DETERRENT & DOOR LOCKTRANSMITTER SUB±ASSY MODULE SET DOOR
CONTROL
AVENSIS REPAIR MANUAL (RM1018E)
Page 3311 of 5135
Within 40 sec.
ON
LOCK
ON±LOCK operation: 1 time
Add Mode
Rewrite Mode
ON±LOCK operation: 2 times
Confirmation Mode
ON±LOCK operation: 3 times
All Clear Mode
ON±LOCK operation: 5 times Number of ON±LOCK operations of ignition switch:Turn ignition switch from LOCK to ON and back to LOCK at approximately
1 second intervals according to the number of times shown below.
Mode Selection:
If the number of the ON±LOCK operations of the ignition switch
is 0, 4 or 6 or more, there will be no response (power door lock and
unlock operation) to inform which mode has been selected.
Remove key from ignition key cylinder.
8. 7.
Within 3 sec.
T1T1: Approx. 1 sec.
Continued from previous page
Continued on next page
ON
LOCKT1 T1
ON
LOCKT1 T1
ON
LOCKT1 T1
± THEFT DETERRENT & DOOR LOCKTRANSMITTER SUB±ASSY MODULE SET DOOR
CONTROL73±23
AVENSIS REPAIR MANUAL (RM1018E)
Page 3312 of 5135

Continued from previous page
Integration relay automatically performs power door LOCK±UNLOCK operation to inform
which mode has been selected.
Response to selected mode (Power door lock operation):
UNLOCKLOCK
LOCK±UNLOCK operation: 1 time Add Mode
Rewrite Mode
Confirmation Mode
All Clear Mode
T1T1: Approx. 1 sec.
T1 T1
T2
T2
T1 T1
LOCK±UNLOCK operation: 2 times
LOCK±UNLOCK operation: The number of registered codes (1 ± 5 times)
LOCK±UNLOCK operation: 5 timesUNLOCKLOCK
UNLOCKLOCK
UNLOCKLOCK
Continued on next page
Registration procedures are completed.
HINT:
In the confirmation mode, when LOCK±UNLOCK operation is performed twice, the
number of registered recognition codes is 2.
In the confirmation mode, when 0 codes are registered, LOCK±UNLOCK operation
is automatically performed 5 times.T2: Approx. 2 sec.
Confirmation Mode and
All Clear ModeAdd Mode or
Rewrite Mode Within
3 sec.
Within
40 sec.
1st time 2nd time
73±24± THEFT DETERRENT & DOOR LOCKTRANSMITTER SUB±ASSY MODULE SET DOOR
CONTROL
AVENSIS REPAIR MANUAL (RM1018E)