TEST ACTION APPLICABILITY
2WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA's EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
Turn the ignition off.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Cabin Heater Assist C1 harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
Measure the resistance of the Dosing Pump Control circuit between the Dosing Pump
harness connector and the Cabin Heater Assist C1 harness connector.
Is the resistance below 5.0 ohms?All
Ye s®Go To 3
No®Repair the Dosing Pump Control circuit for an open.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
3WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA's EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
Turn the ignition off.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Cabin Heater Assist C2 harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
Measure the resistance of the Ground circuit between the Dosing Pump harness
connector and the Cabin Heater Assist C2 harness connector.
Is the resistance below 5.0 ohms?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
316
CABIN HEATER
B1820 DOSING PUMP CIRCUIT: OPEN OR SHORT TO BATTERY Ð
Continued
Page 346 of 4284

TEST ACTION APPLICABILITY
4WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA's EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
Turn the ignition off.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
Disconnect the Dosing Pump rubber insulators from the splash shield.
Measure the resistance of the Dosing Pump.
Is the resistance between 3.0 and 10.0 ohms?All
Ye s®Replace the DCHA Heater Module in accordance with the Service
Information.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
No®Replace the Dosing Pump in accordance with the Service Infor-
mation.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
317
CABIN HEATER
B1820 DOSING PUMP CIRCUIT: OPEN OR SHORT TO BATTERY Ð
Continued
Page 347 of 4284
Symptom:
B1820 DOSING PUMP CIRCUIT: SHORT TO GROUND
When Monitored and Set Condition:
B1820 DOSING PUMP CIRCUIT: SHORT TO GROUND
When Monitored: During Dosing Pump activation.
Set Condition: This DTC will set if the DCHA Control detects a high current draw on the
Dosing Pump circuit output pin.
POSSIBLE CAUSES
DOSING PUMP SHORTED TO GROUND
DOSING PUMP CONTROL CIRCUIT SHORTED TO THE GROUND CIRCUIT
DOSING PUMP CONTROL CIRCUIT SHORTED TO GROUND
DCHA CONTROL UNIT FAULT
318
CABIN HEATER
Page 348 of 4284

TEST ACTION APPLICABILITY
1WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA's EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
CAUTION: DO NOT PERFORM THIS TEST UNLESS DIRECTED HERE BY
THE CABIN HEATER PRE-TEST. ALWAYS PERFORM THE CABIN HEATER
PRE-TEST PRIOR TO PERFORMING ANY OTHER CABIN HEATER TEST
FOR THE RESULT TO BE VALID.
NOTE: If present, diagnose and repair DTC B1811 Heater Overheated and
any other conditions relating to overheating before diagnosing this DTC.
Turn the ignition off.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
Turn the ignition on.
Set the Blend Control to the max cool position.
Turn the A/C - Heater Control Module's Power switch off.
With the DRBIIIt, erase Cabin Heater DTCs.
Start the engine.
Allow the engine to idle.
Turn the A/C - Heater Control Module's Power switch on.
Turn the Blower switch to the high speed position.
CAUTION: Do not activate the DCHA Field Mode Test with the engine off.
Failure to follow these instructions may result in internal damage to the
DCHA Heater Module.
NOTE: Do not disconnect the vehicle's battery or the DCHA's main power
supply while the DCHA is in operation or in run-down mode. Failure to
follow these instructions may result in excess emissions from the DCHA
during heater operation.
With the DRBIIItin Cabin Heater, Systems Tests, select Field Mode and press Enter.
Set the Blend Control to the max heat position. Upon completion of the Field Mode
Test, proceed as follows:
With the DRBIIIt, read Cabin Heater DTCs.
Turn the Blower switch off and turn the A/C - Heater Control Module's Power switch
off.
Turn the engine off.
Is DTC B1820 Dosing Pump Circuit: Short to Ground present?All
Ye s®Go To 2
No®Replace the Dosing Pump in accordance with the Service Infor-
mation.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
319
CABIN HEATER
B1820 DOSING PUMP CIRCUIT: SHORT TO GROUND ÐContinued
Page 349 of 4284

TEST ACTION APPLICABILITY
2WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA's EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
CAUTION: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
Turn the ignition off.
Disconnect the battery in accordance with the Service information.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Cabin Heater Assist C1 and C2 harness connectors.
Measure the resistance between the Dosing Pump Control circuit and the Ground
circuit.
Is the resistance below 10K ohms?All
Ye s®Repair the Dosing Pump Control circuit for a short to the Ground
circuit.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
No®Go To 3
3WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA's EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
Turn the ignition off.
Disconnect the battery in accordance with the Service information.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Cabin Heater Assist C1 harness connector.
Measure the resistance between ground and the Dosing Pump Control circuit.
Is the resistance below 10K ohms?All
Ye s®Repair the Dosing Pump Control circuit for a short to ground.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
No®Replace the DCHA Heater Module in accordance with the Service
Information.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
320
CABIN HEATER
B1820 DOSING PUMP CIRCUIT: SHORT TO GROUND ÐContinued
Page 350 of 4284

Symptom List:
B1821 COMBUSTION AIR FAN CIRCUIT: OPEN
B1821 COMBUSTION AIR FAN CIRCUIT: SHORT TO GROUND
Test Note: All symptoms listed above are diagnosed using the same tests.
The title for the tests will be B1821 COMBUSTION AIR FAN
CIRCUIT: OPEN.
When Monitored and Set Condition:
B1821 COMBUSTION AIR FAN CIRCUIT: OPEN
When Monitored: After DCHA activation, when the system is in a steady state of
operation.
Set Condition: This DTC will set if the DCHA Control detects no-load voltage on the
Combustion Air Fan circuit output pin.
B1821 COMBUSTION AIR FAN CIRCUIT: SHORT TO GROUND
When Monitored: After DCHA activation, when the system is in a steady state of
operation.
Set Condition: This DTC will set if the DCHA Control detects a high current draw on the
Combustion Air Fan circuit output pin.
POSSIBLE CAUSES
COMBUSTION AIR FAN/DCHA CONTROL UNIT FAULT
TEST ACTION APPLICABILITY
1WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA's EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
CAUTION: DO NOT PERFORM THIS TEST UNLESS DIRECTED HERE BY
THE CABIN HEATER PRE-TEST. ALWAYS PERFORM THE CABIN HEATER
PRE-TEST PRIOR TO PERFORMING ANY OTHER CABIN HEATER TEST
FOR THE RESULT TO BE VALID.
NOTE: If present, diagnose and repair DTC B1801 Flame Out before diag-
nosing this DTC.
Turn the ignition off.
View repairAll
Repair
Replace the DCHA Heater Module in accordance with the Service
Information.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
321
CABIN HEATER
Page 351 of 4284

Symptom List:
B1822 GLOW PIN/FLAME SENSOR: OPEN
B1822 GLOW PIN/FLAME SENSOR: SHORT TO GROUND
Test Note: All symptoms listed above are diagnosed using the same tests.
The title for the tests will be B1822 GLOW PIN/FLAME SEN-
SOR: OPEN.
When Monitored and Set Condition:
B1822 GLOW PIN/FLAME SENSOR: OPEN
When Monitored: After DCHA activation.
Set Condition: This DTC will set if the Glow Pin resistance is not within the expected
parameters.
B1822 GLOW PIN/FLAME SENSOR: SHORT TO GROUND
When Monitored: After DCHA activation, when the system is in a steady state of
operation.
Set Condition: This DTC will set if the Glow Pin resistance is not within the expected
parameters.
POSSIBLE CAUSES
GLOW PIN/HEATER MODULE FAULT
TEST ACTION APPLICABILITY
1WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA's EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
CAUTION: DO NOT PERFORM THIS TEST UNLESS DIRECTED HERE BY
THE CABIN HEATER PRE-TEST. ALWAYS PERFORM THE CABIN HEATER
PRE-TEST PRIOR TO PERFORMING ANY OTHER CABIN HEATER TEST
FOR THE RESULT TO BE VALID.
Turn the ignition off.
View repairAll
Repair
Replace the DCHA Heater Module in accordance with the Service
Information.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
322
CABIN HEATER
Page 352 of 4284

Symptom List:
B1823 WATER PUMP CIRCUIT: OPEN
B1823 WATER PUMP CIRCUIT: SHORT TO GROUND
Test Note: All symptoms listed above are diagnosed using the same tests.
The title for the tests will be B1823 WATER PUMP CIRCUIT:
OPEN.
When Monitored and Set Condition:
B1823 WATER PUMP CIRCUIT: OPEN
When Monitored: During DCHA activation and operation.
Set Condition: This fault is erroneous for this DCHA assembly.
B1823 WATER PUMP CIRCUIT: SHORT TO GROUND
When Monitored: During DCHA activation and operation.
Set Condition: This fault is erroneous for this DCHA assembly.
POSSIBLE CAUSES
DCHA CONTROL UNIT FAULT
TEST ACTION APPLICABILITY
1WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA's EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
CAUTION: DO NOT PERFORM THIS TEST UNLESS DIRECTED HERE BY
THE CABIN HEATER PRE-TEST. ALWAYS PERFORM THE CABIN HEATER
PRE-TEST PRIOR TO PERFORMING ANY OTHER CABIN HEATER TEST
FOR THE RESULT TO BE VALID.
Turn the ignition off.
View repairAll
Repair
Replace the DCHA Heater Module in accordance with the Service
Information.
Perform CABIN HEATER VERIFICATION TEST - VER 1.
323
CABIN HEATER