2001 CHRYSLER VOYAGER Service Manual

Page 505 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
LEFT REAR TURN SIGNAL OUTPUT SHORT
When Monitored and Set Condition:
LEFT REAR TURN SIGNAL OUTPUT SHORT
When Monitored: Anytime the BCM is active.
Set Condition: When output voltage status is

Page 506 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
3 Turn the ignition off.
Disconnect the Left Rear Turn Signal Lamp connector.
Turn the ignition on.
Turn the Left Turn Signal on.
Using a 12-volt test light connected to grou

Page 507 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
LEFT SIDE PARK LAMP OPEN
When Monitored and Set Condition:
LEFT SIDE PARK LAMP OPEN
When Monitored: Anytime the FCM is active.
Set Condition: When B+ voltage is below 10.0 volts.
POSSIBLE CAU

Page 508 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
3 Turn the ignition off.
Disconnect the left front park lamp connector.
Turn the ignition on.
Turn the Park Lamps on.
Using a 12-volt test light connected to ground, check th

Page 509 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
PARK LAMP OUTPUT 1 OPEN
When Monitored and Set Condition:
PARK LAMP OUTPUT 1 OPEN
When Monitored: Ignition on.
Set Condition: The IPM detects high current from the Park Lamp Relay Control cir

Page 510 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
4 Turn the ignition off.
Install a known good relay in place of the park lamp relay.
Turn the Park Lamps On.
Do the Park Lamps operate normally?All
Ye s®Replace the Park Lam

Page 511 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
PARK LAMP OUTPUT 1 SHORT TO BATTERY
When Monitored and Set Condition:
PARK LAMP OUTPUT 1 SHORT TO BATTERY
When Monitored: Ignition on.
Set Condition: When a battery fault condition is present

Page 512 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
PARK LAMP OUTPUT 2 OPEN
When Monitored and Set Condition:
PARK LAMP OUTPUT 2 OPEN
When Monitored: Ignition on.
Set Condition: The IPM detects high current from the Park Lamp Relay Control cir