Page 449 of 5621

ATC-2Revision: 2006 January2006 M35/M45 AUTO SWITCH ................................................... 34
DEFROSTER (DEF) SWITCH ............................. 34
UPPER VENT SWITCH ...................................... 34
A/C SWITCH ....................................................... 35
FAN SWITCHES .................................................. 35
OFF SWITCH ...................................................... 35
REAR WINDOW DEFOGGER SWITCH ............. 35
INTAKE SWITCH ................................................. 35
DUAL SWITCH .................................................... 35
Control Operation (Rear Control Switch) ................ 35
AUTO SWITCH ................................................... 35
FAN SWITCH ...................................................... 35
REAR TEMPERATURE CONTROL SWITCH ..... 35
Fail-Safe Function .................................................. 36
Discharge Air Flow ................................................. 37
System Description ................................................. 38
SWITCHES AND THEIR CONTROL FUNCTION ... 38
CAN Communication System Description .............. 39
TROUBLE DIAGNOSIS ............................................ 40
CONSULT-II Function (ECM) .................................. 40
CONSULT-II BASIC OPERATION ....................... 40
DATA MONITOR .................................................. 40
How to Perform Trouble Diagnosis for Quick and
Accurate Repair ...................................................... 40
WORK FLOW ...................................................... 40
SYMPTOM TABLE .............................................. 41
Component Parts and Harness Connector Location ... 42
ENGINE COMPARTMENT .................................. 42
PASSENGER COMPARTMENT .......................... 43
Schematic ............................................................... 44
Wiring Diagram —A/C— ......................................... 46
Auto Amp. Terminals and Reference Value ............ 53
PIN CONNECTOR TERMINAL LAYOUT ............ 53
TERMINALS AND REFERENCE VALUE FOR
UNIFIED METER AND A/C AMP. ........................ 53
Self-diagnosis Function .......................................... 55
DESCRIPTION .................................................... 55
FUNCTION CONFIRMATION PROCEDURE ...... 56
AUXILIARY MECHANISM: TEMPERATURE
SETTING TRIMMER ........................................... 62
AUXILIARY MECHANISM: FOOT POSITION
SETTING TRIMMER ........................................... 63
AUXILIARY MECHANISM: INLET PORT MEM-
ORY FUNCTION ................................................. 63
Operational Check .................................................. 64
CHECKING MEMORY FUNCTION ..................... 64
CHECKING BLOWER ......................................... 64
CHECKING DISCHARGE AIR (MODE SWITCH
AND DEF SWITCH) ............................................ 64
CHECKING DISCHARGE AIR (UPPER VENT
SWITCH) ............................................................. 65
CHECKING INTAKE AIR ..................................... 65
CHECKING TEMPERATURE DECREASE ......... 65
CHECKING TEMPERATURE INCREASE .......... 65
CHECKING A/C SWITCH ................................... 65
CHECKING AUTO MODE ................................... 65
Power Supply and Ground Circuit for Auto Amp. ... 66
INSPECTION FLOW ........................................... 66
COMPONENT DESCRIPTION ............................ 67DIAGNOSIS PROCEDURE FOR A/C SYSTEM ... 67
Rear Control Switch Circuit ..................................... 69
DIAGNOSIS PROCEDURE FOR REAR CON-
TROL SWITCH .................................................... 69
LAN System Circuit ................................................. 70
DIAGNOSIS PROCEDURE FOR LAN CIRCUIT ... 70
Mode Door Motor Circuit ......................................... 75
INSPECTION FLOW ............................................ 76
SYSTEM DESCRIPTION ..................................... 78
COMPONENT DESCRIPTION ............................ 79
DIAGNOSIS PROCEDURE FOR MODE DOOR
MOTOR ................................................................ 79
Upper Ventilator Door Motor Circuit ........................ 80
INSPECTION FLOW ............................................ 80
SYSTEM DESCRIPTION ..................................... 81
COMPONENT DESCRIPTION ............................ 82
DIAGNOSIS PROCEDURE FOR UPPER VEN-
TILATOR DOOR MOTOR .................................... 82
Air Mix Door Motor Circuit ....................................... 83
INSPECTION FLOW ............................................ 83
SYSTEM DESCRIPTION ..................................... 84
COMPONENT DESCRIPTION ............................ 85
DIAGNOSIS PROCEDURE FOR AIR MIX DOOR
MOTOR ................................................................ 85
Air Mix Door Motor PBR Circuit .............................. 85
DIAGNOSIS PROCEDURE FOR AIR MIX DOOR
MOTOR PBR ....................................................... 85
Intake Door Motor Circuit ........................................ 86
INSPECTION FLOW ............................................ 86
SYSTEM DESCRIPTION ..................................... 87
COMPONENT DESCRIPTION ............................ 88
DIAGNOSIS PROCEDURE FOR INTAKE DOOR
MOTOR ................................................................ 88
Blower Motor Circuit ................................................ 89
INSPECTION FLOW ............................................ 89
SYSTEM DESCRIPTION ..................................... 90
COMPONENT DESCRIPTION ............................ 91
DIAGNOSIS PROCEDURE FOR BLOWER
MOTOR ................................................................ 91
COMPONENT INSPECTION ............................... 93
Magnet Clutch Circuit .............................................. 94
INSPECTION FLOW ............................................ 94
SYSTEM DESCRIPTION ..................................... 95
DIAGNOSIS PROCEDURE FOR MAGNET
CLUTCH .............................................................. 95
COMPONENT INSPECTION ............................... 98
Insufficient Cooling .................................................. 99
INSPECTION FLOW ............................................ 99
PERFORMANCE TEST DIAGNOSIS ................101
PERFORMANCE CHART ..................................103
TROUBLE DIAGNOSIS FOR UNUSUAL PRES-
SURE .................................................................105
DIAGNOSIS PROCEDURE FOR INSUFFI-
CIENT COOLING ...............................................107
Insufficient Heating ...............................................109
INSPECTION FLOW ..........................................109
Noise .....................................................................110
INSPECTION FLOW ..........................................110
Self-Diagnosis ....................................................... 111
Page 450 of 5621

ATC-3
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 January2006 M35/M45 INSPECTION FLOW ......................................... . 111
Memory Function .................................................. 112
INSPECTION FLOW .......................................... 112
Ambient Sensor Circuit ......................................... 113
COMPONENT DESCRIPTION .......................... 113
AMBIENT TEMPERATURE INPUT PROCESS .. 113
DIAGNOSIS PROCEDURE FOR AMBIENT
SENSOR ............................................................ 113
COMPONENT INSPECTION ............................. 115
In-Vehicle Sensor Circuit ....................................... 116
COMPONENT DESCRIPTION .......................... 116
DIAGNOSIS PROCEDURE FOR IN-VEHICLE
SENSOR ............................................................ 117
COMPONENT INSPECTION ............................. 118
Sunload Sensor Circuit ......................................... 119
COMPONENT DESCRIPTION .......................... 119
SUNLOAD INPUT PROCESS ........................... 119
DIAGNOSIS PROCEDURE FOR SUNLOAD
SENSOR ............................................................ 119
COMPONENT INSPECTION ............................121
Intake Sensor Circuit ............................................122
COMPONENT DESCRIPTION .........................122
DIAGNOSIS PROCEDURE FOR INTAKE SEN-
SOR ..................................................................122
COMPONENT INSPECTION ............................123
CONTROLLER .......................................................124
Removal and Installation of Multifunction Switch . 124
REMOVAL ........................................................
.124
INSTALLATION .................................................124
AUTO AMP .............................................................125
Removal and Installation of Unified Meter and A/C
Auto Amp. ............................................................125
REMOVAL ........................................................
.125
INSTALLATION .................................................125
AMBIENT SENSOR ................................................126
Removal and Installation ......................................126
REMOVAL ........................................................
.126
INSTALLATION .................................................126
IN-VEHICLE SENSOR ............................................127
Removal and Installation ......................................127
REMOVAL ........................................................
.127
INSTALLATION .................................................127
SUNLOAD SENSOR ..............................................128
Removal and Installation ......................................128
REMOVAL ........................................................
.128
INSTALLATION .................................................128
INTAKE SENSOR .................................................. .129
Removal and Installation ......................................129
REMOVAL ........................................................
.129
INSTALLATION .................................................129
BLOWER UNIT .......................................................130
Removal and Installation ......................................130
REMOVAL ........................................................
.130
INSTALLATION .................................................130
Disassembly and Assembly .................................131
BLOWER MOTOR ..................................................132
Removal and Installation ......................................132
REMOVAL ........................................................
.132
INSTALLATION .................................................132INTAKE DOOR MOTOR .........................................133
Removal and Installation ......................................133
REMOVAL ........................................................
.133
INSTALLATION .................................................133
IN-CABIN MICROFILTER .......................................134
Removal and Installation ......................................134
FUNCTION .......................................................
.134
REPLACEMENT TIMING ..................................134
REPLACEMENT PROCEDURES .....................134
HEATER & COOLING UNIT ASSEMBLY ...............135
Removal and Installation ......................................135
REMOVAL ........................................................
.135
INSTALLATION .................................................136
Disassembly and Assembly ..................................138
MODE DOOR MOTOR ............................................140
Removal and Installation ......................................140
REMOVAL ........................................................
.140
INSTALLATION .................................................140
AIR MIX DOOR MOTOR .........................................141
Removal and Installation ......................................141
REMOVAL ........................................................
.141
INSTALLATION .................................................141
UPPER VENTILATOR DOOR MOTOR ..................142
Removal and Installation ......................................142
REMOVAL ........................................................
.142
INSTALLATION .................................................142
HEATER CORE .......................................................143
Removal and Installation ......................................143
REMOVAL ........................................................
.143
INSTALLATION .................................................143
DUCTS AND GRILLES ...........................................144
Removal and Installation ......................................144
COMPONENT LAYOUT ....................................144
REMOVAL ........................................................
.146
INSTALLATION .................................................150
REFRIGERANT LINES ...........................................151
HFC-134a (R-134a) Service Procedure ...............151
SETTING OF SERVICE TOOLS AND EQUIP-
MENT ................................................................151
Components ....................................................
.....153
VQ35DE ............................................................153
VK45DE .............................................................154
Removal and Installation of Compressor ..............155
REMOVAL ........................................................
.155
INSTALLATION .................................................157
Check Disc to Pulley Clearance ...........................157
Removal and Installation of Low-Pressure Flexible
Hose and Pipe ......................................................158
REMOVAL ........................................................
.158
INSTALLATION .................................................158
Removal and Installation of High-Pressure Flexible
Hose .....................................................................159
REMOVAL ........................................................
.159
INSTALLATION .................................................160
Removal and Installation of High-Pressure Pipe 1
(Engine Compartment) .........................................160
REMOVAL ........................................................
.160
INSTALLATION .................................................161
Removal and Installation of Low-Pressure Pipe 1
Page 451 of 5621

ATC-4Revision: 2006 January2006 M35/M45 and High-Pressure Pipe 2 ....................................162
REMOVAL ........................................................
.162
INSTALLATION ..................................................163
Removal and Installation of Liquid Tank ...............164
DISASSEMBLY AND ASSEMBLY ....................164
REMOVAL ........................................................
.164
INSTALLATION ..................................................165
Removal and Installation of Condenser ................165
REMOVAL ........................................................
.165
INSTALLATION ..................................................167
Removal and Installation of Refrigerant Pressure
Sensor ..................................................................167
REMOVAL ........................................................
.167
INSTALLATION ..................................................167
Removal and Installation of Evaporator ................168
REMOVAL ........................................................
.168
INSTALLATION ..................................................168Removal and Installation of Expansion Valve .......169
REMOVAL ..........................................................169
INSTALLATION ..................................................169
Checking for Refrigerant Leaks ............................170
Checking System for Leaks Using the Fluorescent
Leak Detector ........................................................170
Dye Injection .........................................................170
Electrical Refrigerant Leak Detector .....................171
PRECAUTIONS FOR HANDLING LEAK
DETECTOR .......................................................171
CHECKING PROCEDURE ................................172
SERVICE DATA AND SPECIFICATIONS (SDS) ....174
Compressor ..........................................................174
Lubricant ...............................................................174
Refrigerant ............................................................174
Engine Idling Speed ..............................................174
Belt Tension ..........................................................174
Page 452 of 5621

PRECAUTIONS
ATC-5
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 January2006 M35/M45
PRECAUTIONSPFP:00001
Precautions for Supplemental Restraint System (SRS) “AIR BAG” and “SEAT
BELT PRE-TENSIONER”
NJS000FN
The Supplemental Restraint System such as “AIR BAG” and “SEAT BELT PRE-TENSIONER”, used along
with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger for certain
types of collision. This system includes seat belt switch inputs and dual stage front air bag modules. The SRS
system uses the seat belt switches to determine the front air bag deployment, and may only deploy one front
air bag, depending on the severity of a collision and whether the front occupants are belted or unbelted.
Information necessary to service the system safely is included in the SRS and SB section of this Service Man-
ual.
WAR NING :
To avoid rendering the SRS inoperative, which could increase the risk of personal injury or death
in the event of a collision which would result in air bag inflation, all maintenance must be per-
formed by an authorized NISSAN/INFINITI dealer.
Improper maintenance, including incorrect removal and installation of the SRS, can lead to per-
sonal injury caused by unintentional activation of the system. For removal of Spiral Cable and Air
Bag Module, see the SRS section.
Do not use electrical test equipment on any circuit related to the SRS unless instructed to in this
Service Manual. SRS wiring harnesses can be identified by yellow and/or orange harnesses or
harness connectors.
Precautions Necessary for Steering Wheel Rotation After Battery DisconnectNJS000FO
NOTE:
This Procedure is applied only to models with Intelligent Key system and NVIS/IVIS (NISSAN/INFINITI
VEHICLE IMMOBILIZER SYSTEM - NATS).
Remove and install all control units after disconnecting both battery cables with the ignition knob in the
LOCK position.
Always use CONSULT-II to perform self-diagnosis as a part of each function inspection after finishing
work. If DTC is detected, perform trouble diagnosis according to self-diagnostic results.
For models equipped with the Intelligent Key system and NVIS/IVIS, an electrically controlled steering lock
mechanism is adopted on the key cylinder.
For this reason, if the battery is disconnected or if the battery is discharged, the steering wheel will lock and
steering wheel rotation will become impossible.
If steering wheel rotation is required when battery power is interrupted, follow the procedure below before
starting the repair operation.
OPERATION PROCEDURE
1. Connect both battery cables.
NOTE:
Supply power using jumper cables if battery is discharged.
2. Use the Intelligent Key or mechanical key to turn the ignition switch to the
ACC position. At this time, the
steering lock will be released.
3. Disconnect both battery cables. The steering lock will remain released and the steering wheel can be
rotated.
4. Perform the necessary repair operation.
5. When the repair work is completed, return the ignition switch to the
LOCK position before connecting
the battery cables. (At this time, the steering lock mechanism will engage.)
6. Perform a self-diagnosis check of all control units using CONSULT-II.
Page 453 of 5621

ATC-6
PRECAUTIONS
Revision: 2006 January2006 M35/M45
Precautions for Procedures without Cowl Top CoverNJS000FP
When performing the procedure after removing cowl top cover, cover
the lower end of windshield with urethane, etc.
Precautions for Working with HFC-134a (R-134a)NJS000FQ
CAUTION:
CFC-12 (R-12) refrigerant and HFC-134a (R-134a) refrigerant are not compatible. If the refrigerants
are mixed and compressor malfunction is likely to occur, refer to “CONTAMINATED REFRIGER-
ANT” below. To determine the purity of HFC-134a (R-134a) in the vehicle and recovery tank, use
Refrigerant Recovery/Recycling Recharging equipment and Refrigerant Identifier.
Use only specified lubricant for the HFC-134a (R-134a) A/C system and HFC-134a (R-134a) compo-
nents. If lubricant other than that specified is used, compressor malfunction is likely to occur.
The specified HFC-134a (R-134a) lubricant rapidly absorbs moisture from the atmosphere. The fol-
lowing handling precautions must be observed:
–When removing refrigerant components from a vehicle, immediately the cap (seal) the component
to minimize the entry of moisture from the atmosphere.
–When installing refrigerant components to a vehicle, never remove the caps (unseal) until just
before connecting the components. Connect all refrigerant loop components as quickly as possi-
ble to minimize the entry of moisture into system.
–Only use the specified lubricant from a sealed container. Immediately reseal containers of lubri-
cant. Without proper sealing, lubricant will become moisture saturated and should not be used.
–Never allow lubricant (Nissan A/C System Oil Type S) to come in contact with styrene foam parts.
Damage may result.
PIIB3706J
Page 454 of 5621

PRECAUTIONS
ATC-7
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 January2006 M35/M45
CONTAMINATED REFRIGERANT
If a refrigerant other than pure HFC-134a (R-134a) is identified in a vehicle, take appropriate steps
shown below:
Explain to the customer that environmental regulations prohibit the release of contaminated refrigerant
into the atmosphere.
Explain that recovery of the contaminated refrigerant could damage service equipment and refrigerant
supply.
Suggest the customer return the vehicle to the location of previous service where the contamination may
have occurred.
In case of repairing, recover the refrigerant using only dedicated equipment and containers. Never
recover contaminated refrigerant into the existing service equipment. If the facility does not have
dedicated recovery equipment, contact a local refrigerant product retailer for available service. This refrig-
erant must be disposed of in accordance with all federal and local regulations. In addition, replacement of
all refrigerant system components on the vehicle is recommended.
If the vehicle is within the warranty period, the air conditioner warranty is void. Please contact Nissan Cus-
tomer Affairs for further assistance.
General Refrigerant PrecautionsNJS000FR
WAR NING :
Avoid breathing A/C refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose and
throat. Remove HFC-134a (R-134a) from the A/C system, using certified service equipment meet-
ing requirements of SAE J-2210 [HFC-134a (R-134a) recycling equipment], or J-2209 [HFC-134a (R-
134a) recovery equipment]. If accidental system discharge occurs, ventilate work area before
resuming service. Additional health and safety information may be obtained from refrigerant and
lubricant manufacturers.
Never release refrigerant into the air. Use approved recovery/recycling equipment to capture the
refrigerant every time an air conditioning system is discharged.
Always wear eye and hand protection (goggles and gloves) when working with any refrigerant or
air conditioning system.
Never store or heat refrigerant containers above 52C (126F).
Never heat a refrigerant container with an open flame; if container warming is required, place the
bottom of the container in a warm pail of water.
Never intentionally drop, puncture, or incinerate refrigerant containers.
Keep refrigerant away from open flames: poisonous gas will be produced if refrigerant burns.
Refrigerant will displace oxygen, therefore be certain to work in well ventilated areas to prevent
suffocation.
Never pressure test or leak test HFC-134a (R-134a) service equipment and/or vehicle air condition-
ing systems with compressed air during repair. Some mixtures of air and HFC-134a (R-134a) have
been shown to be combustible at elevated pressures. These mixtures, if ignited, may cause injury
or property damage. Additional health and safety information may be obtained from refrigerant
manufacturers.
Precautions for Refrigerant ConnectionNJS000FS
A new type refrigerant connection has been introduced to all refrigerant lines except the following location.
Expansion valve to evaporator
Refrigerant pressure sensor to liquid tank
ABOUT ONE-TOUCH JOINT
Description
One-touch joints are pipe joints which do not require tools during piping connection.
Unlike conventional connection methods using union nuts and flanges, controlling tightening torque at
connection point is not necessary.
When removing a pipe joint, use a disconnector.
Page 455 of 5621
ATC-8
PRECAUTIONS
Revision: 2006 January2006 M35/M45
COMPONENT PARTS
FUNCTIONS OF COMPONENT PARTS
NOTE:
Garter spring (2) cannot be removed from cage (A) of male-side piping.
Indicator ring (3) remains near piping connection point, however, this is not a malfunction. (This is to
check piping connection during factory assembly.)
REMOVAL
1. Clean piping connection point, and set a disconnector.
1 Pipe (Male side)Retains O-rings (4).
Retains garter spring (2) in cage (A).
2 Garter spring Anchors female side piping (5).
3 Indicator ringWhen connection is made properly, this is ejected from male-side piping (1). (This part is no longer
necessary after connection.)
4 O-ring Seals connection point. (Not reusable)
5 Pipe (Female side)
Seals connection by compressing O-rings (4).
Anchors piping connection using flare (B) and garter spring (2).
RJIA4383J
SJIA0106E
Page 456 of 5621

PRECAUTIONS
ATC-9
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 January2006 M35/M45
2. Slide disconnector in axial direction of piping, and stretch garter spring with tapered point of disconnector.
3. Slide disconnector farther so that inside diameter of garter spring becomes larger than outside diameter of
female-side piping flare. Then male-side piping can be disconnected.
INSTALLATION
1. Clean piping connection points, and insert male-side piping into female-side piping.
2. Push inserted male-side piping harder so that female-side piping flare stretches garter spring.
3. If inside diameter of garter spring becomes larger than outside diameter of female-side piping flare, garter
spring seats on flare. Then, it fits in between male-side piping cage and female-side piping flare to anchor
piping connection point.
NOTE:
When garter spring seats on flare, and fits in between male-side piping cage and female-side piping flare,
it clicks.
CAUTION:
Female-side piping connection is thin and easy to deform. Slowly insert the male-side piping
straight in axial direction.
Insert piping securely until a click is heard.
After piping connection is completed, pull male-side piping by hand to make sure that connec-
tion does not come loose.
NOTE:
One-touch joint connection is used in points below.
Low-pressure flexible hose to low-pressure pipe 1 (O-ring size: 16)
High-pressure flexible hose to condenser (O-ring size: 12)
High-pressure pipe 1 to high-pressure pipe 2 (O-ring size: 8)
High-pressure pipe 1 to condenser (O-ring size: 8)
SJIA0107E