2006 INFINITI FX35 Service Manual

Page 953 of 4462

INFINITI FX35 2006  Service Manual INTELLIGENT KEY SYSTEM BL-139
C 
D  E 
F 
G  H 
J 
K  L 
M  A 
B
BL 
Revision: 2006 December 2006 FX35/FX45
3. CHECK INSIDE KEY ANTENNA 
1. Disconnect Intelligent Key unit connector. 
2. Check continu

Page 954 of 4462

INFINITI FX35 2006  Service Manual BL-140
INTELLIGENT KEY SYSTEM
Revision: 2006 December 2006 FX35/FX45
2. CHECK STEERING LOCK UNIT GROUND CIRCUIT 
Check continuity between steering lock unit connector M26 terminal 4 (Y/B) and ground.

Page 955 of 4462

INFINITI FX35 2006  Service Manual INTELLIGENT KEY SYSTEM BL-141
C 
D  E 
F 
G  H 
J 
K  L 
M  A 
B
BL 
Revision: 2006 December 2006 FX35/FX45
4. CHECK STEERING LOCK UNIT COMMUNICATION CIRCUIT 
1. Disconnect Intelligent Key unit and st

Page 956 of 4462

INFINITI FX35 2006  Service Manual BL-142
INTELLIGENT KEY SYSTEM
Revision: 2006 December 2006 FX35/FX45
3. CHECK STOP LAMP SWITCH GROUND CIRCUIT 
1. Check continuity between stop lamp switch connector E210 ter-  minal 2 (P) and Intelli

Page 957 of 4462

INFINITI FX35 2006  Service Manual INTELLIGENT KEY SYSTEM BL-143
C 
D  E 
F 
G  H 
J 
K  L 
M  A 
B
BL 
Revision: 2006 December 2006 FX35/FX45
2. CHECK DETENTION SWITCH CIRCUIT 
1. Disconnect A/T device (detention switch) connector. 
2

Page 958 of 4462

INFINITI FX35 2006  Service Manual BL-144
INTELLIGENT KEY SYSTEM
Revision: 2006 December 2006 FX35/FX45
4. DETENTION SWITCH GROUND CIRCUIT INSPECTION 
Check continuity between A/T device (detention switch) connector 
M67 terminal 2 (B)

Page 959 of 4462

INFINITI FX35 2006  Service Manual INTELLIGENT KEY SYSTEM BL-145
C 
D  E 
F 
G  H 
J 
K  L 
M  A 
B
BL 
Revision: 2006 December 2006 FX35/FX45
Check Hazard FunctionNIS001O0
1. CHECK HAZARD WARNING LAMP 
Does hazard warning lamp flash w

Page 960 of 4462

INFINITI FX35 2006  Service Manual BL-146
INTELLIGENT KEY SYSTEM
Revision: 2006 December 2006 FX35/FX45
2. CHECK IPDM E/R HARNESS 
1. Turn ignition switch OFF. 
2. Disconnect IPDM E/R and horn relay connector.
3. Check continuity betwe