Page 2649 of 3189
SIIA1645E
Trouble Diagnosis/QG and YD Engine Models
with Common Rail
NJEL0581CONSULT-II INSPECTION PROCEDURENJEL0581S011. Turn ignition switch “OFF”.
2. Connect CONSULT-II to the data link connector.
MBIB0233E
3. Turn ignition switch “ON”.
4. Touch “START (NISSAN BASED VHCL)”.
SIIA1678E
5. Touch “SMART ENTRANCE”.
SIIA1676E
6. Touch “DOOR LOCK” or “TRUNK RELEASE”.
SIIA1677E
7. Select diagnosis mode.
“DATA MONITOR” and “WORK SUPPROT” are available.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail
EL-313
Page 2650 of 3189
![NISSAN ALMERA N16 2003 Electronic Repair Manual CONSULT-II APPLICATION ITEMSNJEL0581S02Door LockingNJEL0581S0201DATA MONITOR
Monitored Item Description
IGNITION SW Indicates [ON/OFF] condition of ignition switch.
KEY IN DETECT Indicates [ON/OFF] co NISSAN ALMERA N16 2003 Electronic Repair Manual CONSULT-II APPLICATION ITEMSNJEL0581S02Door LockingNJEL0581S0201DATA MONITOR
Monitored Item Description
IGNITION SW Indicates [ON/OFF] condition of ignition switch.
KEY IN DETECT Indicates [ON/OFF] co](/manual-img/5/57350/w960_57350-2649.png)
CONSULT-II APPLICATION ITEMSNJEL0581S02Door LockingNJEL0581S0201DATA MONITOR
Monitored Item Description
IGNITION SW Indicates [ON/OFF] condition of ignition switch.
KEY IN DETECT Indicates [ON/OFF] condition of key switch.
DOOR SW DR RR Indicates [ON/OFF] condition of rear door switch (driver side).
DOOR SW AS RR Indicates [ON/OFF] condition of rear door switch (passenger side).
AS DOOR SW Indicates [ON/OFF] condition of front door switch (passenger side).
DR DOOR SW Indicates [ON\OFF] condition of front door switch (driver side).
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from door lock/ unlock switch.
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from door lock/ unlock switch.
RKE LOCK Indicates [ON/OFF] condition of lock signal from remote controller.
RKE UNLOCK Indicates [ON/OFF] condition of unlock signal from remote controller.
RKE SEL UNLOCK Indicates [ON/OFF] condition of select unlock signal from remote controller.
WORK SUPPORT
Monitored Item Description
AUTO RE-LOCKAuto re-lock function can be changed in this mode. The re-lock mode will be changed when
“CHANGE MODE” on CONSULT-II screen is touched.
SELECTIVE UNLOCKSelective unlock function can be changed in this mode. The unlock mode willbe changed when
“CHANGE SET” on CONSULT-II screen is touched.
Trunk ReleaseNJEL0581S0202DATA MONITOR
Monitored Item Description
IGNITION SW Indicates [ON/OFF] condition of ignition switch.
TRUNK OPEN SW Indicates [ON/OFF] condition of trunk room lamp switch (sedan) or back door switch (wagon).
INT TRUNK RELIndicates [ON/OFF] condition of internal trunk release switch (sedan) orinternal back door
release switch (wagon).
EXT TRUNK RELIndicates [ON/OFF] condition of external trunk release switch (sedan) orexternal back door
release switch (wagon).
RKE TRUNK RELIndicates [ON/OFF] condition of trunk (sedan) or back door (back door) open signal from trunk
or back door release switch.
WORK SUPPORT
Monitored Item Description
TRUNK OPEN DELAYThis mode can be changed trunk release switch (sedan) or back door (wagon) release switch
operation time.
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-314
Page 2651 of 3189
PRELIMINARY CHECK=NJEL0581S03First perform the “SELF-DIAG RESULTS” in “SMART ENTRANCE”
with CONSULT-II, when perform the each trouble diagnosis. Refer
to EL-313, “CONSULT-II INSPECTION PROCEDURE”.
SIIA1601E
After performing preliminary check, go to SYMPTOM CHART.
Before starting trouble diagnoses below, perform preliminary
check.
Symptom numbers in the symptom chart correspond with those of
Preliminary check.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-315
Page 2652 of 3189

SYMPTOM CHARTNJEL0581S04
Symptom Malfunctioning systemReference
page
SYMPTOM 1
Power door lock does not operate using any switchPower supply and ground circuit check EL-317
Door lock actuator check EL-321
If above systems are OK, replace smart entrance con-
trol unit.—
SYMPTOM 2
Power door lock does not operate with lock/unlock
switch.Door lock/unlock switch check EL-319
If above system is OK, replace smart entrance control
unit.—
SYMPTOM 3
Specific door lock actuator does not operate.Door lock actuator check EL-321
If above system is OK, replace smart entrance control
unit.—
SYMPTOM 4
Super lock cannot be set by door key cylinder.Super lock actuator check EL-336
Key switch check EL-335
Ignition switch ON circuit check EL-318
If above systems are OK, replace smart entrance con-
trol unit.—
SYMPTOM 5
*Super lock cannot be released by door key cylinder.Super lock actuator check EL-336
If above systems are OK, replace smart entrance con-
trol unit.—
SYMPTOM 6
*Super lock cannot be released by ignition key switch.Super lock actuator check EL-336
Ignition switch “ON” circuit check EL-318
If above systems are OK, replace smart entrance con-
trol unit.—
SYMPTOM 7
Specific super lock actuator does not operate.Super lock actuator check EL-336
If above system is OK, replace smart entrance control
unit.—
SYMPTOM 8
*Key reminder system does not operate.Door switch check EL-327
Trunk room lamp switch or back door switch check —
Key switch check EL-335
If above system is OK, replace smart entrance control
unit.—
*: Make sure the power door lock system operates properly.
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-316
Page 2653 of 3189
POWER SUPPLY AND GROUND CIRCUIT CHECKNJEL0581S05
1 CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect smart entrance control unit connector.
3. Check voltage between smart entrance control unit harness connector M195 terminal 49 (W/L), 56 (R/B) and ground.
SIIA1564E
MTBL1480
OK or NG
OK GO TO 2.
NG Check smart entrance control unit power supply circuit for open or short.
2 CHECK GROUND CIRCUIT
Check continuity between smart entrance control unit harness connector M195 terminal 53 (B) and ground.
SIIA1565E
MTBL1481
OK or NG
OK Power supply and ground circuit is OK.
NG Check smart entrance control unit ground circuit for open or short.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-317
Page 2654 of 3189
IGNITION SWITCH “ON” CIRCUIT CHECKNJEL0581S11
1 CHECK IGNITION ON SIGNAL
1. Disconnect smart entrance control unit connector.
2. Check voltage between smart entrance control unit harness connector M194 terminal 29 (Y/G) and ground.
SIIA1602E
MTBL1553
OK or NG
OK Ignition ON signal is OK.
NGCheck the following.
10A fuse [No. 10, located in fuse block (J/B)]
Harness for open or short between smart entrance control unit and fuse
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-318
Page 2655 of 3189
DOOR LOCK/UNLOCK SWITCH CHECKNJEL0581S06
1 CHECK DOOR LOCK/UNLOCK SWITCH SIGNAL
With CONSULT-II
Check door lock/unlock switch input signal (“CDL LOCK SW” “CDL UNLOCK SW”)in “DATA MONITOR” mode with
CONSULT-II.
SIIA1566E
When door lock/unlock switch is turned to LOCK:
CDL LOCK SW⇒ON
When door lock/unlock switch is turned to UNLOCK:
CDL UNLOCK SW⇒ON
Without CONSULT-II
1. Disconnect smart entrance control unit harness connector.
2. Check continuity between smart entrance control unit harness connector M193 terminal 13 (P), 14 (L) and ground.
SIIA1567E
MTBL1482
OK or NG
OK Door lock/unlock switch is OK.
NG GO TO 2.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-319
Page 2656 of 3189
2 CHECK DOOR LOCK/UNLOCK SWITCH
1. Disconnect door lock/unlock switch harness connector.
2. Check continuity between each door lock/unlock switch terminals.
Power window main switch (Door lock/unlock switch) (With power window system)
YEL803C
Door lock/unlock switch (Without power window system)
SEL469X
OK or NG
OKCheck the following.
Ground circuit for door lock/unlock switch
Harness for open or short between door lock/unlock switch and smart entrance control
unit connector
NG Replace power window main switch (door lock/unlock switch).
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-320