Page 2665 of 3189
Passenger SideNJEL0581S0802
1 CHECK DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check door switch “AS DOOR SW” in “DATA MONITOR” mode with CONSULT-II.
SIIA1591E
MTBL1499
Without CONSULT-II
1. Turn ignition switch OFF.
2. Check voltage between smart entrance control unit harness connector M194 terminal 44 (R/W) and ground.
SIIA1592E
MTBL1500
OK or NG
OK Door switch is OK.
NG GO TO 2.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-329
Page 2666 of 3189
2 CHECK DOOR SWITCH
Check continuity between front door switch RH harness connector B19 terminal 1 (R/W) and ground.
SIIA1589E
MTBL1501
OK or NG
OKCheck the following.
Front door switch RH ground condition
Harness for open or short between smart entrance control unit and front door switch
RH
NG Replace front door switch RH.
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-330
Page 2667 of 3189
Rear LH SideNJEL0581S0803
1 CHECK DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check door switch “RR LH DOOR SW” in “DATA MONITOR” mode with CONSULT-II.
SIIA1593E
MTBL1502
Without CONSULT-II
1. Turn ignition switch OFF.
2. Check voltage between smart entrance control unit harness connector M194 terminal 39 (BR/W) and ground.
SIIA1597E
MTBL1503
OK or NG
OK Door switch is OK.
NG GO TO 2.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-331
Page 2668 of 3189
2 CHECK DOOR SWITCH
Check continuity between rear door switch LH harness connector B24 terminal 1 (BR/W) and ground.
SIIA1595E
MTBL1504
OK or NG
OKCheck the following.
Rear door switch LH ground condition
Harness for open or short between smart entrance control unit and rear doorswitch
LH
NG Replace rear door switch LH.
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-332
Page 2669 of 3189
Rear RH SideNJEL0581S0804
1 CHECK DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check door switch “RR RH DOOR SW” in “DATA MONITOR” mode with CONSULT-II.
SIIA1596E
MTBL1505
Without CONSULT-II
1. Turn ignition switch OFF.
2. Check voltage between smart entrance control unit harness connector M194 terminal 45 (R/Y) and ground.
SIIA1594E
MTBL1506
OK or NG
OK Door switch is OK.
NG GO TO 2.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-333
Page 2670 of 3189
2 CHECK DOOR SWITCH
Check continuity between rear door switch RH harness connector B35 terminal 1 (R/Y) and ground.
SIIA1595E
MTBL1507
OK or NG
OKCheck the following.
Rear door switch RH ground condition
Harness for open or short between smart entrance control unit and rear doorswitch
RH
NG Replace rear door switch RH.
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-334
Page 2671 of 3189
KEY SWITCH CHECKNJEL0581S09
1 CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch input signal “KEY IN DETECT” in “DATA MONITOR” mode with CONSULT-II.
SIIA1598E
When key is inserted in ignition key cylinder:
KEY IN DETECT⇒ON
When key is removed from ignition key cylinder:
KEY IN DETECT⇒OFF
Without CONSULT-II
Check voltage between smart entrance control unit harness connector M193terminal 5 (L/W) and ground.
SIIA1599E
MTBL1508
OK or NG
OK Key switch is OK.
NG GO TO 2.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-335
Page 2672 of 3189
2 CHECK KEY SWITCH (INSERT)
1. Disconnect key switch connector.
2. Check continuity between key switch terminals 1 and 2.
YEL791C
OK or NG
OKCheck the following.
10A fuse [No. 12, located in fuse block (J/B)]
Harness for open or short between key switch and fuse
Harness for open or short between smart entrance control unit and key switch
NG Replace key switch.
SUPER LOCK ACTUATOR CHECKNJEL0581S10Front DoorNJEL0581S1001
1 CHECK OUTPUT SIGNAL FOR SUPER LOCK ACTUATOR
Check voltage between smart entrance control unit harness connector F195terminal 52 (W/R), 55 (W/B) and ground.
SIIA1609E
MTBL1510
OK or NG
OK GO TO 2.
NG Replace smart entrance control unit.
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis/QG and YD Engine Models with Common Rail (Cont’d)
EL-336