Page 2529 of 4323

N16207
Thermometer
Ice
More than
10 cm (3.94in.)1
2
I28971Temperature Resistance (kW)
9.0 10.0
8.0
5.07.0
4.0
2.0 3.0
0.0
14 32 50 68 86 ±10 0 10 20 30
(F) (C) 6.0
1.0
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2327
2521 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check front evaporator temperature sensor.
PREPARATION:
Remove the front evaporator temperature sensor.
CHECK:
Measure the resistance between terminals 1 and 2 of the evap-
orator temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±2±10C (14F)7.40 to 9.20 kW
1±2±5C (23F)5.65 to 7.00 kW
1±20C (32F)4.35 to 5.40 kW
1±25C (41F)3.40 to 4.20 kW
1±210C (50F)2.68 to 3.30 kW
1±215C (59F)2.10 to 2.60 kW
1±220C (68F)1.66 to 2.10 kW
1±225C (77F)1.32 to 1.66 kW
1±230C (86F)1.05 to 1.35 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace front evaporator temperature sensor.
OK
3 Check harness and connector between front evaporator temperature sensor and
integration control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2530 of 4323
I08286
E2
Engine Coolant
Temp. Sensor
1 2Integration Control and Panel
I22 E821
28
E8E2 THWECM
THWO
E5 14
W±R2 G±Y
G±WTW DI±2328
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2522 Author: Date:
2005 SEQUOIA (RM1146U)
DTC 14 Engine Coolant Temperature Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the engine coolant temperature and sends the appropriate signals to the integration
control and panel. These signals are used for warm up control when the engine is cold.
DTC No.Detection ItemTrouble Area
14Open or short in engine coolant temperature sensor circuit.
Engine coolant temp. sensor
Harness or connector between engine coolant temp. sensor
and ECM
Harness or connector between ECM and integration control
and panel
ECM
Integration control and panel
WIRING DIAGRAM
DI935±03
Page 2531 of 4323
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2329
2523 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
1 Is DTC P0115, P0117 or P0118 output?
YES Go to engine troubleshooting
(See page DI±9).
NO
2 Check harness and connector between ECM and integration control and panel.
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2532 of 4323
I15861
Integration Control and Panel
A29
A/C Evaporator Temp.
Sensor (Rear)I21
RrTE 17
LG±R
BH18
1
2
1
L±R
L±R10
RrSG 18
IJ3
6 LG±R
BH1 LG±R w/ Rear A/C:
L±R
IJ3
I21 DI±2330
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2524 Author: Date:
2005 SEQUOIA (RM1146U)
DTC 17 Rear Evaporator Temperature Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the rear evaporator temperature and sends the appropriate signals to the integration
control and panel.
DTC No.Detection ItemTrouble Area
17Open or short in rear evaporator temperature sensor circuit.
Rear evaporator temp. sensor
Harness or connector between rear evaporator temp. sensor
and integration control and panel
Integration control and panel
WIRING DIAGRAM
DIDKW±01
Page 2533 of 4323
I28847
RrSG
RrTEI21 Integration Control and Panel:
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2331
2525 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
1 Check voltage between terminals RrTE and RrSG of integration control and pan-
el.
PREPARATION:
Remove the integration control and panel with connectors still
connected.
CHECK:
(a) Turn the ignition switch to ON.
(b) Measure the voltage between terminals RrTE and RrSG
of the integration control and panel connector at each
temperature.
OK:
Voltage :
at 0°C (32°F) : 2.0 to 2.4 V
at 15°C (59°F) : 1.4 to 1.8 V
HINT:
As the temperature increases, the voltage decreases.
NG Go to step 2.
OK
Proceed to next circuit inspection shown in problem symptoms table (See page DI±2304). How-
ever, if DTC 17 is displayed, replace integration control and panel.
Page 2534 of 4323

N16207
Thermometer
Ice
More than
10 cm (3.94in.)1
2
I28971Temperature Resistance (kW)
9.0 10.0
8.0
5.07.0
4.0
2.0 3.0
0.0
14 32 50 68 86 ±10 0 10 20 30
(F) (C) 6.0
1.0
DI±2332
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2526 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check rear evaporator temperature sensor.
PREPARATION:
Remove the rear evaporator temperature sensor (See page
AC±42).
CHECK:
Measure the resistance between terminals 1 and 2 of the evap-
orator temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±2±10C (14F)7.40 to 9.20 kW
1±2±5C (23F)5.65 to 7.00 kW
1±20C (32F)4.35 to 5.40 kW
1±25C (41F)3.40 to 4.20 kW
1±210C (50F)2.68 to 3.30 kW
1±215C (59F)2.10 to 2.60 kW
1±220C (68F)1.66 to 2.10 kW
1±225C (77F)1.32 to 1.66 kW
1±230C (86F)1.05 to 1.35 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace rear evaporator temperature sensor.
OK
3 Check harness and connector between rear evaporator temperature sensor and
integration control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2535 of 4323
I24455
A31
A/C Room Temp.
Sensor (Rear)
2
SG±RrTRRrTR Integration Control and Panel
14 13
I22
I22 GR±R B
1 w/ Rear A/C:
GR±R
R±Y R±YJ31
E J32F
AJ/C
J31 J32
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2333
2527 Author: Date:
2005 SEQUOIA (RM1146U)
DTC 19 Rear Room Temperature Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the temperature inside the cabin and sends the appropriate signals to the integration
control and panel.
DTC No.Detection ItemTrouble Area
19Open or short in rear room temperature sensor circuit.
Rear room temp. sensor
Harness or connector between rear room temp. sensor and
integration control and panel
Integration control and panel
WIRING DIAGRAM
DIDKX±01
Page 2536 of 4323
I28847
RrTR SG±RrTRI22 Integration Control and Panel:
DI±2334
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2528 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
1 Check voltage between terminals RrTR and SG±RrTR of integration control and
panel.
PREPARATION:
Remove the integration control and panel with connectors still
connected.
CHECK:
(a) Turn the ignition switch to ON.
(b) Measure the voltage between terminals RrTR and SG±
RrTR of the integration control and panel connector at
each temperature.
OK:
Voltage :
at 25°C (77°F) : 1.8 to 2.2 V
at 40°C (104°F) : 1.2 to 1.6 V
HINT:
As the temperature increases, the voltage decreases.
NG Go to step 2.
OK
Proceed to next circuit inspection shown in problem symptoms table (See page DI±2304). How-
ever, if DTC19 is displayed, replace integration control and panel.