Page 4081 of 4555
HEADLAMP AIMING CONTROL (AUTO)
LT-85
C
D
E
F
G
H
I
J
L
MA
B
LT
4. CHECK HEADLAMP AIMING MOTOR RH
1. Connect headlamp aiming motor RH connector only.
2. Turn ignition switch ON.
3. Check if “ACT OUTPUT” and “ACT MEASURED” indicated the
same value.
OK or NG
OK >> GO TO 5.
NG >> Replace headlamp RH. Refer to LT- 2 1 , "
Removal and
Installation of Headlamp" in HEADLAMP - XENON
TYPE -.
5. CHECK HEADLAMP AIMING MOTOR LH
1. Turn ignition switch OFF.
2. Disconnect headlamp aiming motor RH connector.
3. Connect headlamp aiming motor LH connector.
4. Turn ignition switch ON.
5. Check if “ACT OUTPUT” and “ACT MEASURED” indicated the
same value.
OK or NG
OK >> Replace height sensor, and initialize it. Refer to LT- 8 6 ,
"Removal and Installation of Height Sensor" and LT- 7 0 ,
"WORK SUPPORT" .
NG >> Replace headlamp LH. Refer to LT- 2 1 , "
Removal and
Installation of Headlamp" in HEADLAMP - XENON TYPE -.
PKIB7209E
PKIB7209E
Page 4082 of 4555
LT-86
HEADLAMP AIMING CONTROL (AUTO)
Removal and Installation of Height SensorEKS00N6H
REMOVAL
1. Turn ignition switch OFF.
2. Disconnect the battery cable from the negative terminal or remove power fuse.
3. Lift-up the vehicle.
4. Disconnect height sensor sub harness connector.
5. Remove linkage mounting bolt.
6. Remove height sensor mounting bolt and remove height sensor
from vehicle.
INSTALLATION
Installation is the reverse order of removal.
NOTE:
Initialize whenever replacing the height sensor. Refer to LT- 7 0 , "
WORK SUPPORT" .
PKIC0424E
Height sensor mounting bolt : 5.5 N·m (0.56 kg-m, 49 in-lb)
Linkage mounting bolt : 5.5 N·m (0.56 kg-m, 49 in-lb)
Page 4083 of 4555

TURN SIGNAL AND HAZARD WARNING LAMPS
LT-87
C
D
E
F
G
H
I
J
L
MA
B
LT
TURN SIGNAL AND HAZARD WARNING LAMPSPFP:26120
System Description EKS003BX
TURN SIGNAL OPERATION
With the hazard switch in the OFF position and the ignition switch in the ON or START position, power is sup-
plied
through 10A fuse [No. 2, located in fuse block (J/B)]
through hazard switch terminal 2
through hazard switch terminal 1
to combination flasher unit terminal 1,
through combination flasher unit terminal 3
to turn signal switch terminal 1.
Ground is supplied
to combination flasher unit terminal 2
through grounds M27 and M70.
LH Turn Signal Lamp
When the turn signal switch is moved to the left position, power is supplied
through turn signal switch terminal 3
to front turn signal lamp LH terminal 1
to side turn signal lamp LH terminal 1
to combination meter terminal 52, and
to rear combination lamp LH terminal 2.
Ground is supplied
to front turn signal lamp LH terminal 2
through grounds E24 and E50,
to side turn signal lamp LH terminal 2
through grounds E24 and E50,
to rear combination lamp LH terminal 4
through grounds B8 and B18,
to combination meter terminal 64
through grounds M27 and M70.
With power and ground supplied, the combination flasher unit controls the flashing of the LH turn signal lamps.
RH Turn Signal Lamp
When the turn signal switch is moved to the right position, power is supplied
through turn signal switch terminal 2
to front turn signal lamp RH terminal 1
to side turn signal lamp RH terminal 1
to combination meter terminal 18, and
to rear combination lamp RH terminal 2.
Ground is supplied
to front turn signal lamp RH terminal 2
through grounds E24 and E50,
to side turn signal lamp RH terminal 2
through grounds E24 and E50,
to rear combination lamp RH terminal 4
through grounds B8 and B18,
to combination meter terminal 64
through grounds M27 and M70.
Page 4084 of 4555

LT-88
TURN SIGNAL AND HAZARD WARNING LAMPS
With power and ground supplied, the combination flasher unit controls the flashing of the RH turn signal
lamps.
HAZARD LAMP OPERATION
Power is supplied at all times
through 10A fuse (No. 35, located in the fuse and fusible link box)
to hazard switch terminal 3.
With the hazard switch in the ON position, power is supplied
through hazard switch terminal 1
to combination flasher unit terminal 1,
through combination flasher unit terminal 3
to hazard switch terminal 4.
Ground is supplied
to combination flasher unit terminal 2
through grounds M27 and M70.
Power is supplied
through hazard switch terminal 5
to front turn signal lamp LH terminal 1
to side turn signal lamp LH terminal 1
to combination meter terminal 52, and
to rear combination lamp LH terminal 2,
through hazard switch terminal 6
to front turn signal lamp RH terminal 1
to side turn signal lamp RH terminal 1
to combination meter terminal 18, and
to rear combination lamp RH terminal 2.
Ground is supplied
to front turn signal lamp LH and RH terminal 2
through grounds E24 and E50,
to side turn signal lamp LH and RH terminal 2
through grounds E24 and E50,
to rear combination lamp LH and RH terminal 4
through grounds B8 and B18,
to combination meter terminal 64
through grounds M27 and M70.
With power and ground supplied, the combination flasher unit controls the flashing of the hazard warning
lamps.
Page 4085 of 4555
TURN SIGNAL AND HAZARD WARNING LAMPS
LT-89
C
D
E
F
G
H
I
J
L
MA
B
LT
Wiring Diagram — TURN — EKS003BY
LHD MODELS
TKWA1526E
Page 4086 of 4555
LT-90
TURN SIGNAL AND HAZARD WARNING LAMPS
TKWA0073E
Page 4087 of 4555
TURN SIGNAL AND HAZARD WARNING LAMPS
LT-91
C
D
E
F
G
H
I
J
L
MA
B
LT
RHD MODELS
TKWA1527E
Page 4088 of 4555
LT-92
TURN SIGNAL AND HAZARD WARNING LAMPS
TKWA1528E