2005 INFINITI QX4 Factory Service Manual

Page 489 of 3419

INFINITI QX4 2005  Factory Service Manual ATC-94
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
SYSTEM DESCRIPTION
Component Parts
Blower speed control system components are:
Front air control
Front blower motor
In-vehicle sensor
Ambie

Page 490 of 3419

INFINITI QX4 2005  Factory Service Manual TROUBLE DIAGNOSIS
ATC-95
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: October 20052005 QX56
Blower Speed Compensation - Sunload
When the in-vehicle temperature and the set temperature are very close, the blo

Page 491 of 3419

INFINITI QX4 2005  Factory Service Manual ATC-96
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
1. CHECK FUSES
Check 20A fuses [No. 24 and 27 (Located in the fuse and fusible link box)]. For fuse layout. Refer to PG-77,
"FUSE AND FUSIBLE L

Page 492 of 3419

INFINITI QX4 2005  Factory Service Manual TROUBLE DIAGNOSIS
ATC-97
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: October 20052005 QX56
5. CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) CIRCUIT FOR OPEN
Check continuity between front blower motor relay

Page 493 of 3419

INFINITI QX4 2005  Factory Service Manual ATC-98
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
9. CHECK FRONT BLOWER MOTOR RELAY (COIL SIDE) GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front blower motor relay

Page 494 of 3419

INFINITI QX4 2005  Factory Service Manual TROUBLE DIAGNOSIS
ATC-99
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: October 20052005 QX56
14. CHECK BLOWER MOTOR GROUND CIRCUIT
Check continuity between front blower motor harness connector
M62 terminal 1

Page 495 of 3419

INFINITI QX4 2005  Factory Service Manual ATC-100
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
COMPONENT INSPECTION
Front Blower Motor Relay
Check continuity between terminals by supplying 12 volts and
ground to coil side terminals of re

Page 496 of 3419

INFINITI QX4 2005  Factory Service Manual TROUBLE DIAGNOSIS
ATC-101
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: October 20052005 QX56
Rear Blower Motor CircuitEJS003XT
SYMPTOM:
Blower motor operation is malfunctioning.
INSPECTION FLOW
*1AT C - 6 0