Page 2649 of 4647
![INFINITI M35 2007 Factory Service Manual EC-1120
[VK45DE]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
Revision: 2007 April2007 M35/M45
Diagnostic ProcedureNBS005HH
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID INFINITI M35 2007 Factory Service Manual EC-1120
[VK45DE]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
Revision: 2007 April2007 M35/M45
Diagnostic ProcedureNBS005HH
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID](/manual-img/42/57024/w960_57024-2648.png)
EC-1120
[VK45DE]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
Revision: 2007 April2007 M35/M45
Diagnostic ProcedureNBS005HH
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve
(1) harness connector.
3. Turn ignition switch ON.
4. Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E108, M15
Harness connectors M72, F102
IPDM E/R harness connector E7
Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid
valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-II)>>GO TO 4.
OK (Without CONSULT-II)>>GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB2688E
Voltage: Battery voltage
PBIB0148E
Continuity should exist.
Page 2650 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-1121
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VAL INFINITI M35 2007 Factory Service Manual DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-1121
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VAL](/manual-img/42/57024/w960_57024-2649.png)
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-1121
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1. Reconnect all harness connectors disconnected.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with
CONSULT-II. Check that engine speed varies according to the
valve opening.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EC-1121, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace EVAP canister purge volume control solenoid valve.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-857, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionNBS005HI
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
Check air passage continuity of EVAP canister purge volume control
solenoid valve under the following conditions.
Without CONSULT-II
Check air passage continuity of EVAP canister purge volume control
solenoid valve under the following conditions.
PBIB1678E
Condition
(PURG VOL CONT/V value)Air passage continuity
between (A) and (B)
100% Yes
0% No
PBIB0149E
ConditionAir passage continuity
between (A) and (B)
12V direct current supply between
terminals 1 and 2Ye s
No supply No
PBIB0150E
Page 2651 of 4647
EC-1122
[VK45DE]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
Revision: 2007 April2007 M35/M45
Removal and InstallationNBS005HJ
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EM-179, "INTAKE MANIFOLD" .
Page 2652 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1123
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0447 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionNBS005HK INFINITI M35 2007 Factory Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1123
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0447 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionNBS005HK](/manual-img/42/57024/w960_57024-2651.png)
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1123
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0447 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionNBS005HK
The EVAP canister vent control valve (1) is located on the EVAP
canister (2) and is used to seal the canister vent.
Illustration shows the view from under the vehicle.
: Vehicle front
EVAP control system pressure sensor (3)
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows EVAP
control system diagnosis.
CONSULT-II Reference Value in Data Monitor ModeNBS005HL
Specification data are reference values.
On Board Diagnosis LogicNBS005HM
PBIB2702E
PBIB1263E
MONITOR ITEM CONDITION SPECIFICATION
VENT CONT/V
Ignition switch: ON OFF
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0447
0447EVAP canister vent con-
trol valve circuit openAn improper voltage signal is sent to ECM
through EVAP canister vent control valve.
Harness or connectors
(The valve circuit is open or shorted.)
EVAP canister vent control valve
Page 2653 of 4647
EC-1124
[VK45DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2007 April2007 M35/M45
DTC Confirmation ProcedureNBS005HN
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and wait at least 8 seconds.
4. If 1st trip DTC is detected, go to EC-1126, "
Diagnostic Proce-
dure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
SEF058Y
Page 2654 of 4647
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1125
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Wiring DiagramNBS005HO
TBWT1539E
Page 2655 of 4647
![INFINITI M35 2007 Factory Service Manual EC-1126
[VK45DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not INFINITI M35 2007 Factory Service Manual EC-1126
[VK45DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not](/manual-img/42/57024/w960_57024-2654.png)
EC-1126
[VK45DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureNBS005HP
1. INSPECTION START
Do you have CONSULT-II?
Ye s o r N o
Yes >> GO TO 2.
No >> GO TO 3.
2. CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT-II
1. Turn ignition switch OFF and then turn ON.
2. Select “VENT CONTROL/V” in “ACTIVE TEST” mode with
CONSULT-II.
3. Touch “ON/OFF” on CONSULT-II screen.
4. Check for operating sound of the valve.
OK or NG
OK >> GO TO 7.
NG >> GO TO 3.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
111 S BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 7 G R / LEVAP canister vent control
valve[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
11 9
120R
RPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
Clicking noise should be heard.
PBIB1679E
Page 2656 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1127
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition s INFINITI M35 2007 Factory Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1127
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition s](/manual-img/42/57024/w960_57024-2655.png)
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1127
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister vent control valve (1) harness con-
nector.
–Illustration shows the view from under the vehicle.
–: Vehicle front
–EVAP canister (2)
–EVAP control system pressure sensor (3)
3. Turn ignition switch ON.
4. Check voltage between EVAP canister vent control valve termi-
nal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E106, B4
Harness connectors B66, B436
Harness connectors B469, B171
IPDM E/R harness connector E7
Harness for open or short between EVAP canister vent control valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 117 and EVAP canister vent control valve terminal 2.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
PBIB2702E
Voltage: Battery voltage
PBIB0152E
Continuity should exist.