Page 2961 of 4647
EC-1432
[VK45DE]
VIAS
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
29 V VIAS control solenoid valve[Engine is running]
Selector lever: P or N0 - 1.0V
[Engine is running]
Selector lever: D
Engine speed: Below 5,000 rpmBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Engine speed: Above 5,000 rpm0 - 1.0V
111 S BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 9
120R
RPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
Page 2962 of 4647
VIAS
EC-1433
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Diagnostic ProcedureNBS005PN
1. CHECK OVERALL FUNCTION
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CON-
SULT-II.
3. Turn VIAS control solenoid valve ON and OFF, and make sure
that power valve actuator (1) rod moves.
Without CONSULT-II
1. Lift up the vehicle.
2. Start engine and warm it up to normal operating temperature.
3. Make sure that power valve actuator (1) rod moves when chang-
ing the gear position to N and D alternately.
OK or NG
OK >>INSPECTION END
NG (With CONSULT-II)>>GO TO 2.
NG (Without CONSULT-II)>>GO TO 3.
PBIB0844E
PBIB2725E
PBIB2725E
Page 2963 of 4647
![INFINITI M35 2007 Factory Service Manual EC-1434
[VK45DE]
VIAS
Revision: 2007 April2007 M35/M45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Start engine and let i INFINITI M35 2007 Factory Service Manual EC-1434
[VK45DE]
VIAS
Revision: 2007 April2007 M35/M45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Start engine and let i](/manual-img/42/57024/w960_57024-2962.png)
EC-1434
[VK45DE]
VIAS
Revision: 2007 April2007 M35/M45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Start engine and let it idle.
3. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CON-
SULT-II.
4. Turn VIAS control solenoid valve ON and OFF, and check vac-
uum existence under the following conditions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
3. CHECK VACUUM EXISTENCE
Without CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Disconnect VIAS control solenoid valve (1) harness connector.
–: Vehicle front
3. Start engine and let it idle.
4. Apply 12V of direct current between VIAS control solenoid valve
terminals 1 and 2.
5. Check vacuum existence under the following conditions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
VIAS SOL VALVE Vacuum
ON Should exist.
OFF Should not exist.
PBIB0844E
PBIB2694E
Condition Vacuum
12V direct current supply Should exist.
No supply Should not exist.
PBIB0845E
Page 2964 of 4647
![INFINITI M35 2007 Factory Service Manual VIAS
EC-1435
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. CHECK VACUUM HOSE
1. Stop engine.
2. Check hoses and tubes between intake manifold and power
valve actuator for crac INFINITI M35 2007 Factory Service Manual VIAS
EC-1435
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. CHECK VACUUM HOSE
1. Stop engine.
2. Check hoses and tubes between intake manifold and power
valve actuator for crac](/manual-img/42/57024/w960_57024-2963.png)
VIAS
EC-1435
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. CHECK VACUUM HOSE
1. Stop engine.
2. Check hoses and tubes between intake manifold and power
valve actuator for crack, clogging, improper connection or dis-
connection. Refer to EC-814, "
Vacuum Hose Drawing" .
OK or NG
OK >> GO TO 5.
NG >> Repair hoses or tubes.
5. CHECK VACUUM TANK
Refer to EC-1436, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace vacuum tank.
6. CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect VIAS control solenoid valve (1) harness connector.
–: Vehicle front
3. Turn ignition switch ON.
4. Check voltage between terminal 1 and ground with CONSULT-II
or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E12, F3
Harness continuity between IPDM E/R and VIAS control solenoid valve
>> Repair open circuit or short to ground or short to power in harness or connectors.
SEF109L
PBIB2694E
Voltage: Battery voltage
PBIB0173E
Page 2965 of 4647
![INFINITI M35 2007 Factory Service Manual EC-1436
[VK45DE]
VIAS
Revision: 2007 April2007 M35/M45
8. CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3 INFINITI M35 2007 Factory Service Manual EC-1436
[VK45DE]
VIAS
Revision: 2007 April2007 M35/M45
8. CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3](/manual-img/42/57024/w960_57024-2964.png)
EC-1436
[VK45DE]
VIAS
Revision: 2007 April2007 M35/M45
8. CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 29 and VIAS control solenoid valve terminal 2.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK VIAS CONTROL SOLENOID VALVE
Refer to EC-1436, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> Replace VIAS control solenoid valve.
10. CHECK INTERMITTENT INCIDENT
Refer to EC-857, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionNBS005PO
VIAS CONTROL SOLENOID VALVE
With CONSULT-II
1. Reconnect harness connectors disconnected.
2. Turn ignition switch ON.
3. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode.
4. Check air passage continuity and operation delay time under the
following conditions.
Operation takes less than 1 second.
Without CONSULT-II
Check air passage continuity and operation delay time under the fol-
lowing conditions.
Operation takes less than 1 second.Continuity should exist.
Condition
VIAS SOL VALVEAir passage continuity
between (A) and (B)Air passage continuity
between (A) and (C)
ON Yes No
OFF No Yes
PBIB0177E
ConditionAir passage continuity
between (A) and (B)Air passage continuity
between (A) and (C)
12V direct current supply
between terminals 1 and 2Ye s N o
No supply No Yes
SEF313Q
Page 2966 of 4647
VIAS
EC-1437
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
VACUUM TANK
1. Disconnect vacuum hose connected to vacuum tank.
2. Connect a vacuum pump to the port A of vacuum tank.
3. Apply vacuum and make sure that vacuum exists at the port B.
Removal and InstallationNBS005PP
VIAS CONTROL SOLENOID VALVE
Refer to EM-179, "INTAKE MANIFOLD" .
PBIB0846E
Page 2967 of 4647
EC-1438
[VK45DE]
MIL AND DATA LINK CONNECTOR
Revision: 2007 April2007 M35/M45
MIL AND DATA LINK CONNECTORPFP:24814
Wiring DiagramNBS005QS
TBWT1508E
Page 2968 of 4647
MIL AND DATA LINK CONNECTOR
EC-1439
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
TBWT1073E