Page 497 of 3371

ATC-92
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
1. CHECK REAR BLOWER MOTOR OPERATION
Blower motor rotates normally when rear fan switch (front) is set at 1 - 4 speed.
OK or NG
OK >> GO TO 2.
NG >> Refer to AT C - 9 3 , "
Trouble Diagnosis Procedure For Rear Blower Motor (1 - 4 Speed)" .
2. CHECK REAR FAN SWITCH (FRONT)
Refer to ATC-99, "
Rear Fan Switch (Front)" .
OK or NG
OK >> GO TO 3.
NG >> Replace rear fan switch (front). Refer to ATC-135, "
FRONT AIR CONTROL"
3. CHECK REAR FAN SWITCH (REAR)
Refer to ATC-99, "
Rear Fan Switch (Rear)" .
OK or NG
OK >> GO TO 4.
NG >> Replace rear fan switch (rear). Refer to ATC-135, "
REAR AIR CONTROL" .
4. CHECK CIRCUIT CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect rear fan switch (front) connector M52 and rear fan
switch (rear) (Rear air control) connector R208.
3. Check voltage between rear fan switch (front) harness connec-
tor M52 terminal 2 (BR) and rear fan switch (rear) (Rear air con-
trol) harness connector R208 terminal 10 (BR).
OK or NG
OK >> Inspection End.
NG >> Repair harness or connector.2 - 10 : Continuity should exist.WJIA0794E
Page 498 of 3371
TROUBLE DIAGNOSIS
ATC-93
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
Trouble Diagnosis Procedure For Rear Blower Motor (1 - 4 Speed)
SYMPTOM:
Rear blower motor does not rotate when rear fan switch (front) is set at 1 - 4 speed.
Inspection Flow
*1AT C - 5 9 , "Operational Check (Rear)"*2AT C - 9 3 , "Trouble Diagnosis Proce-
dure For Rear Blower Motor (1 - 4
Speed)"
*3ATC-35, "SYMPTOM TABLE"
WJIA0795E
Page 499 of 3371

ATC-94
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
1. DIAGNOSTIC PROCEDURE
Blower motor rotates normally at each speed.
OK or NG
OK >> Inspection End.
NG >> 1. Does not rotate at any speed, GO TO 2.
2. Does not rotate at 1 - 3 speed, GO TO 13.
3. Does not rotate at 4 speed, GO TO 18.
2. CHECK FUSES
Check 15A fuses [Nos. 10 and 11, located in the fuse block (J/B)]. Refer to PG-76, "
FUSE BLOCK-JUNCTION
BOX(J/B)" .
OK or NG
OK >> GO TO 3.
NG >> GO TO 8.
3. CHECK REAR BLOWER MOTOR POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect rear blower motor connector B134.
3. Select any rear blower speed except OFF.
4. Turn ignition switch ON.
5. Check voltage between rear blower motor harness connector
B134 terminal 2 (L/R) and ground.
OK or NG
OK >> GO TO 11.
NG >> GO TO 4.
4. CHECK REAR BLOWER MOTOR RELAY
Refer to ATC-99, "
Rear Blower Motor Relay" .
OK or NG
OK >> GO TO 5.
NG >> Replace rear blower motor relay.
5. CHECK REAR BLOWER MOTOR POWER FROM RELAY TO REAR BLOWER MOTOR
1. Turn ignition switch OFF.
2. Reconnect rear blower motor connector.
3. Disconnect rear blower motor relay J1.
4. Turn ignition switch ON.
5. Set rear fan switch (front) to any position except off (0), rear (R),
or 4 - speed.
6. Momentarily (no more than 4 seconds), connect a jumper wire
between rear blower motor relay connector J1 terminals 3 and 5.
OK or NG
OK >> GO TO 6.
NG >> GO TO 10.1 - Ground : Battery voltage should exist.
WJIA0596E
Rear blower motor should rotate.LJIA0100E
Page 500 of 3371

TROUBLE DIAGNOSIS
ATC-95
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
6. CHECK REAR BLOWER MOTOR RELAY (COIL SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) connector M39.
3. Turn ignition switch ON.
4. Set rear fan switch (front) to any position except off (0), rear (R),
or 4 - speed.
5. Check voltage between fuse block (J/B) harness connector M39
terminal 3Q (W/L) and ground.
OK or NG
OK >> GO TO 7.
NG >> GO TO 20.
7. CHECK REAR BLOWER MOTOR RELAY (COIL SIDE) GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) connector M3.
3. Check continuity between fuse block (J/B) harness connector
M3 terminal 7N (B) and ground.
OK or NG
OK >> Replace fuse block (J/B).
NG >> Repair harness or connector.
8. REPLACE FUSE
Refer to PG-76, "
FUSE BLOCK-JUNCTION BOX(J/B)" .
Fuse should not open when rear blower motor is activated.
OK or NG
OK >> Inspection End.
NG >> GO TO 9.
9. CHECK REAR BLOWER MOTOR POWER SUPPLY CIRCUIT FOR SHORT
1. Turn ignition switch OFF.
2. Disconnect battery cables and rear blower motor connector
B134.
3. Check continuity between rear blower motor harness connector
B134 terminal 2 (L/R) and ground.
OK or NG
OK >> Check rear blower motor. Refer to ATC-100, "Rear
Blower Motor" .
NG >> Repair harness or connector.1 - Ground : Battery voltage should exist.
LJIA0101E
7N - Ground : Continuity should exist.
WJIA0597E
2 - Ground : Continuity should not exist.
WJIA0598E
Page 501 of 3371

ATC-96
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
10. CHECK REAR BLOWER MOTOR RELAY (SWITCH SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) connector M3 and rear blower motor
connector B134.
3. Check continuity between fuse block (J/B) harness connector
M3 terminal 3N (SB) and 8N (L/R) and rear blower motor har-
ness connector B134 terminal 2 (L/R).
OK or NG
OK >> GO TO 20.
NG >> Repair harness or connector.
11 . CHECK REAR BLOWER MOTOR
Refer to ATC-100, "
Rear Blower Motor" .
OK or NG
OK >> GO TO 12.
NG >> Replace rear blower motor. Refer to ATC-141, "
REAR BLOWER MOTOR" .
12. CHECK REAR FAN SWITCH (FRONT)
Refer to ATC-99, "
Rear Fan Switch (Front)" .
OK or NG
OK >> GO TO 15.
NG >> Replace rear fan switch (front). Refer to ATC-135, "
FRONT AIR CONTROL" .
13. CHECK REAR BLOWER MOTOR RESISTOR
Refer to ATC-100, "
Rear Blower Motor Resistor" .
OK or NG
OK >> GO TO 14.
NG >> Replace rear blower motor resistor. Refer to ATC-156, "
Removal and Installation" .
14. CHECK REAR FAN SWITCH (FRONT) CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect rear fan switch (front) M52.
3. Reconnect rear blower motor resistor harness connector B133.
4. Turn ignition switch ON.
5. Check voltage between each rear fan switch (front) connector
M52 terminals 3 (LG), 7 (W/L), and 8 (G), and ground.
OK or NG
OK >> GO TO 17.
NG >> GO TO 16.3N, 8N - 2 : Continuity should exist.
WJIA0599E
Te r m i n a l N o .
Voltage
(Approx.)
(+) (-)
3
Ground 12V 7
8
LJIA0108E
Page 502 of 3371

TROUBLE DIAGNOSIS
ATC-97
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
15. CHECK REAR BLOWER MOTOR GROUND CIRCUIT TO REAR BLOWER MOTOR RESISTOR
1. Turn ignition switch OFF.
2. Disconnect rear blower motor connector B134 and rear blower
motor resistor connector B133.
3. Check continuity between rear blower motor connector B134
terminal 1 (L/B) and rear blower motor resistor harness connec-
tor B133 terminal 3 (L/B).
4. Check continuity between rear blower motor connector B134
terminal 1 (L/B) and ground.
OK or NG
OK >> GO TO 16.
NG >> Repair harness or connector.
16. CHECK REAR FAN SWITCH (FRONT) CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect rear fan switch (front) connector M52.
3. Check continuity between rear fan switch (front) connector M52
terminals 3 (LG), 7 (W/L), and 8 (G), and rear blower motor
resistor connector B133 terminals 1 (LG), 4 (W/L), and 2 (G).
OK or NG
OK >> Inspection End.
NG >> Repair harness or connector.
17. CHECK REAR FAN SWITCH (FRONT) CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect rear fan switch (rear) (Rear air control) connector
R208.
3. Check continuity between rear fan switch (front) connector M52
terminals 3 (LG), 5 (L/B), 7 (W/L), and 8 (G), and rear fan switch
(rear) (Rear air control) connector R208 terminals 9 (LG), 6 (L/
B), 8 (W/L), and 7 (G).
OK or NG
OK >> GO TO 18.
NG >> Repair harness or connector.1 - 3 : Continuity should exist.
1 - Ground : Continuity should not exist.
WJIA0798E
Te r m i n a l N o .
Continuity
Rear fan switch (front) Rear blower motor resistor
31
Should exist 74
82
WJIA0839E
Terminal No.
Continuity
Rear fan switch (front) Rear fan switch (rear)
39
Should exist 56
78
87
WJIA0799E
Page 503 of 3371
ATC-98
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
18. CHECK REAR FAN SWITCH (FRONT)
Refer to ATC-99, "
Rear Fan Switch (Front)" .
OK or NG
OK >> GO TO 19.
NG >> Replace rear fan switch (front). Refer to ATC-135, "
FRONT AIR CONTROL" .
19. CHECK REAR FAN SWITCH (REAR)
Refer to ATC-99, "
Rear Fan Switch (Rear)" .
OK or NG
OK >> Inspection End.
NG >> Replace rear fan switch (rear). Refer to ATC-135, "
REAR AIR CONTROL" .
20. CHECK CIRCUIT BETWEEN FRONT AIR CONTROL AND FUSE BLOCK (J/B) [REAR BLOWER
MOTOR RELAY (COIL SIDE) POWER]
1. Disconnect front air control connector M50 and fuse block (J/B)
connector M39.
2. Check continuity between front air control harness connector
M50 terminal 38 (W/L) and fuse block (J/B) connector M39 ter-
minal 3Q (W/L).
OK or NG
OK >> Replace front air control. Refer to ATC-135, "FRONT
AIR CONTROL"
NG >> Repair harness or connector.38 - 3Q : Continuity should exist.LJ IA 0 111E
Page 504 of 3371
TROUBLE DIAGNOSIS
ATC-99
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
COMPONENT INSPECTION
Rear Blower Motor Relay
Check circuit continuity between terminals by supplying 12 volts and
ground to coil side terminals of relays.
Rear Fan Switch (Rear)
Check continuity between terminals at each switch position.
Rear Fan Switch (Front)
Check continuity between terminals at each switch position.
WJIA0896E
WJIA0800E
WJIA0897E