Page 881 of 3371

BL-116
AUTOMATIC BACK DOOR SYSTEM
Revision: August 20072004 QX56
4. Using the inside emergency release lever, open the back door.
5. Have an assistant press and hold the back door handle switch.
6. While the assistant continues to hold the back door handle switch, turn ignition switch ON (DO NOT start
engine).
7. After approximately 5 seconds, the back door warning chime will sound for 0.5 seconds.
8. Release the back door handle switch.
9. Within 8 seconds of the back door warning chime sounding, press the power liftgate switch 5 times in
rapid succession.
10. After approximately 5 seconds, the back door warning chime will sound for 1 second.
11. Release the power liftgate switch.
12. Immediately close the back door manually.
13. Press and release the power liftgate switch to activate operating check mode.
Self-diagnosis results are indicated by the back door warning chime.
Turn ignition switch OFF to end input signal check mode.
Diagnosis ChartEIS002T1
Back door warning chime order Back door warning chime length
Start self-diagnosis1.5 seconds
OK NG
1. Operating conditions diagnosis 0.5 seconds 0.2 seconds
2. Back door encoder diagnosis 0.5 seconds 0.2 seconds
3. Back door clutch diagnosis 0.5 seconds 0.2 seconds
4. Back door motor diagnosis 0.5 seconds 0.2 seconds
5. Cinch latch motor diagnosis 0.5 seconds 0.2 seconds
Restart self-diagnosis 1.5 seconds
Item NG Result Refer to
1. Operating conditions diagnosis resultOne of the following operating conditions no
longer met: ignition switch ON, back door
close switch (CANCEL) ON, A/T selector lever
in P position—
2. Back door encoder diagnosis resultSensor diagnosis/short, pulse signal, pulse
signal directionBL-117
3. Back door clutch diagnosis result Back door clutch does not operateBL-124
4. Back door motor diagnosis resultBack door motor does not operate (no operat-
ing current)BL-117
5. Cinch latch motor diagnosis resultCinch latch motor does not operate (no oper-
ating current)BL-128
Symptom Suspect systems Refer to
Automatic operations are not executed from the back door fully
closed or fully open position.
(Auto closure operates normally.)Power liftgate switch system inspectionBL-118
Park switch —
Power window serial linkBL-114
Pinch strip system inspectionBL-122
Automatic operations are not carried out together with open/close
operations.
(Manual operations are normal.)Power liftgate switch system inspectionBL-118Back door close switch system inspectionBL-120
Auto back door power supply and ground cir-
cuit system inspection.BL-117
The auto closure function does not operate.
(Stops at the halfway position for auto closing operations.)Pinch strip system inspectionBL-122
Page 882 of 3371

AUTOMATIC BACK DOOR SYSTEM
BL-117
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Back Door Power Supply and Ground Circuit InspectionEIS002T2
1. BACK DOOR POWER SUPPLY CIRCUIT INSPECTION
1. Turn ignition switch OFF.
2. Disconnect back door control unit.
3. Check voltage between back door control unit connector B55
terminals 3, 10 and ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
2. BACK DOOR GROUND CIRCUIT INSPECTION
Check continuity between back door control unit connector B55 ter-
minal 1, 2 and ground.
OK or NG
OK >> Circuit is OK.
NG >> Repair or replace harness.
During auto closing operations, if obstruction is detected, the
door does not operate in reverse.Back door motor assembly —
During close or cinch operations, the door does not operate in
reverse if the back door handle is operated.Handle switch systemBL-127
When the keyfob is operated, the back door does not operate
automatically.Remote keyless entry system inspectionBL-44Power window serial linkBL-114
Pinch strip system inspectionBL-122
Auto closure does not operate.Half-latch switch systemBL-124Cinch latch motor systemBL-128
Handle switch systemBL-127
The back door does not open.
(Closure motor rotation is not reversed.)Open switch systemBL-125
Handle switch systemBL-127
Warning chime does not sound. Back door warning chime systemBL-123
Auto closure operation works, but the back door is not fully
closedClose switch systemBL-126Handle switch systemBL-127
Cinch latch motor systemBL-128
Back door latch assembly mechanism dam-
aged or worn.— Symptom Suspect systems Refer to
3 (Y/R) - Ground : Approx. battery voltage
10 (L/B) - Ground : Approx. battery voltage
WIIA0567E
1 (B) - Ground : Continuity should exist.
2 (B) - Ground : Continuity should exist.
LIIA0801E
Page 883 of 3371

BL-118
AUTOMATIC BACK DOOR SYSTEM
Revision: August 20072004 QX56
Power Liftgate Switch System InspectionEIS002T3
1. POWER LIFTGATE SWITCH FUNCTION INSPECTION
Check power liftgate switch using switch operation.
OK or NG
OK >> Power liftgate switch is OK.
NG >> GO TO 2.
2. POWER LIFTGATE SWITCH POWER SUPPLY CIRCUIT INSPECTION
1. Turn ignition switch OFF.
2. While operating the power liftgate switch, check voltage
between back door control unit connector B55 terminal 23 and
ground.
OK or NG
OK >> Switch is OK.
NG >> GO TO 3.
3. POWER LIFTGATE SWITCH CIRCUIT INSPECTION
1. Disconnect power liftgate switch and back door control unit connector.
2. Check continuity between back door control unit connector (A)
B55 terminal 23 and power liftgate switch connector (B) M92 ter-
minal 1.
3. Check continuity between power liftgate switch connector (B)
M92 terminal 1 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness.
4. POWER LIFTGATE SWITCH GROUND INSPECTION
Check continuity between power liftgate switch connector terminal 2
and ground.
OK or NG
OK >> Replace the power liftgate switch.
NG >> Repair or replace harness.
Connector terminal
(Wire color)
ConditionVoltage (V)
(Approx.)
( + ) ( - )
23 (L/W) GroundPower liftgate
switchON 0
OFF 5
LIIA0802E
1 (L/W) - 23 (L/W) : Continuity should exist.
1 (L/W) - ground : Continuity should not exist.
LIIA2254E
2 (B) - Ground : Continuity should exist.
LIIA1065E
Page 884 of 3371

AUTOMATIC BACK DOOR SYSTEM
BL-119
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
GLASS HATCH AJAR SWITCH CHECK
1. CHECK GLASS HATCH AJAR SWITCH INPUT SIGNAL
With CONSULT-II
Check glass hatch ajar switch ("TRNK OPN MNTR") in DATA MONITOR mode with CONSULT–II. Refer to
BL-27, "
DATA MONITOR" .
When glass hatch is open:
When glass hatch is closed:
Without CONSULT-II
Check voltage between BCM connector M19 terminal 42 and ground.
OK or NG
OK >> System is OK.
NG >> GO TO 2.
2. CHECK GLASS HATCH AJAR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect glass hatch ajar switch, BCM and back door control unit.
3. Check continuity between glass hatch ajar switch connector D707 terminal + and BCM connector M19 ter-
minal 42.
4. Check continuity between glass hatch ajar switch connector
D707 terminal + and back door control unit connector B55 termi-
nal 17.
5. Check continuity between glass hatch ajar switch connector
D707 terminal + and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.TRNK OPN MNTR : ON
TRNK OPN MNTR : OFF
WIIA0108E
Connec-
torItemTerminals (Wire color)
ConditionVoltage (V)
(Approx.)
( + ) ( – )
M19 BCM 42 (GR) GroundOpen
↓
Closed0
↓
5
LIIA1149E
+ (GR) - 42 (GR) : Continuity should exist
+ (GR) - 17 (GR) : Continuity should exist
+ (GR) - Ground : Continuity should not exist
LIIA1547E
Page 885 of 3371

BL-120
AUTOMATIC BACK DOOR SYSTEM
Revision: August 20072004 QX56
3. CHECK GLASS HATCH AJAR SWITCH
Check continuity between glass hatch ajar switch connector terminal
and ground.
OK or NG
OK >> Check glass hatch ajar switch case ground.
NG >> Replace glass hatch ajar switch.
Back Door Close (Close) Switch System InspectionEIS002T4
1. BACK DOOR CLOSE SWITCH FUNCTION INSPECTION
Check back door close (close) switch using switch operation.
OK or NG
OK >> Back door close switch is OK.
NG >> GO TO 2.
2. BACK DOOR CLOSE SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door close switch, check voltage
between back door control unit connector B55 terminal 8 and
ground.
OK or NG
OK >> Switch is OK.
NG >> GO TO 3.
3. BACK DOOR CLOSE SWITCH CIRCUIT INSPECTION
1. Disconnect back door close switch and back door control unit connector.
2. Check continuity between back door control unit connector (A)
B55 terminal 8 and back door close switch connector (B) B63
terminal 1.
3. Check continuity between back door close switch connector (B)
B63 terminal 1 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
Terminal Condition Continuity
Glass hatch ajar
switch + – GroundOpen Yes
Closed No
LIIA1151E
Connector terminal
(Wire color)Position of back door close
switchVoltage (V)
(Approx.)
( + ) ( - )
8 (GR/B) GroundMomentary
close positionON 0
OFF 5
LIIA0805E
1 (GR/B) - 8 (GR/B) : Continuity should exist.
1 (GR/B) - Ground : Continuity should not exist.
LIIA2255E
Page 886 of 3371

AUTOMATIC BACK DOOR SYSTEM
BL-121
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
4. BACK DOOR CLOSE SWITCH GROUND INSPECTION
Check continuity between back door close switch connector B63 ter-
minal 3 and ground.
OK or NG
OK >> Replace the back door close switch.
NG >> Repair or replace harness.
Back Door Close (Cancel) Switch System InspectionEIS002T5
1. BACK DOOR CLOSE SWITCH FUNCTION INSPECTION
Check back door close (cancel) switch using switch operation.
OK or NG
OK >> Back door close switch is OK.
NG >> GO TO 2.
2. BACK DOOR CLOSE (CANCEL) SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door close (cancel) switch, check volt-
age between back door control unit connector B55 terminal 13
and ground.
OK or NG
OK >> Switch is OK.
NG >> GO TO 3.
3. BACK DOOR CLOSE (CANCEL) SWITCH CIRCUIT INSPECTION
1. Disconnect back door close switch and back door control unit connector.
2. Check continuity between back door control unit connector (A)
B55 terminal 13 and back door close switch connector (B) B63
terminal 5.
3. Check continuity between back door close switch connector (B)
B63 terminal 5 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.3 (B) - Ground : Continuity should exist.
WIIA0602E
Connector terminal
(Wire color)Position of back door close
switchVoltage (V)
(Approx.)
( + ) ( - )
13 (P/L) Ground Cancel positionON 0
OFF 5
LIIA1068E
5 (P/L) - 13 (P/L) : Continuity should exist.
5 (P/L) - ground : Continuity should not exist.
LIIA2256E
Page 887 of 3371

BL-122
AUTOMATIC BACK DOOR SYSTEM
Revision: August 20072004 QX56
4. BACK DOOR CLOSE SWITCH GROUND INSPECTION
Check continuity between back door close switch connector B63 ter-
minal 3 and ground.
OK or NG
OK >> Replace the back door close switch.
NG >> Repair or replace harness.
Pinch Strip System InspectionEIS002T6
1. PINCH STRIP SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the pinch strip, check voltage between back
door control unit connector B55 terminals 19, 20 and ground.
OK or NG
OK >> Switch is OK.
NG >> GO TO 2.
2. PINCH STRIP CIRCUIT INSPECTION
1. Disconnect pinch strip and back door control unit.
2. Check continuity between back door control unit connector (A)
B55 terminal 5, 19 (RH), 20 (LH) and pinch strip connector (B)
D715 (RH), D517 (LH) terminals 1, 2.
3. Check continuity between pinch strip connector (B) D715 (RH),
D517 (LH) terminal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair the harness between the pinch strip and the back door control unit.3 (B) - Ground : Continuity should exist.
WIIA0602E
Connector terminal
(Wire color)
ConditionVoltage (V)
(Approx.)
( + ) ( - )
19 (BR/B)
20 (V/G)GroundPinch strip operation 0
Other 5
LIIA0811E
1 (BR/B) - 19 (BR/B) : Continuity should exist.
1 (V/G) - 20 (V/G) : Continuity should exist.
2 (B/P) - 5 (B/P) : Continuity should exist.
1 (BR/B) - ground : Continuity should not exist.
1 (V/G) - ground) : Continuity should not exist.
LIIA2257E
Page 888 of 3371

AUTOMATIC BACK DOOR SYSTEM
BL-123
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
3. PINCH STRIP GROUND INSPECTION
1. Connect back door control unit.
2. Check continuity between pinch strip connector terminal 2 and
ground.
OK or NG
OK >> Replace the pinch strip.
NG >> Repair or replace harness.
Back Door Warning Chime System InspectionEIS002T7
1. BACK DOOR WARNING CHIME CIRCUIT INSPECTION
1. Disconnect back door warning chime and back door control unit.
2. Check continuity between back door control unit connector (A)
B55 terminal 6 and back door warning chime connector (B)
D514 terminal 1.
3. Check continuity between back door warning chime connector
(B) D514 terminal 1 and ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
2. WARNING CHIME CIRCUIT INSPECTION
1. Connect back door control unit.
2. Check continuity between warning chime connector D514 termi-
nal 2 and ground.
OK or NG
OK >> Replace warning chime.
NG >> Repair or replace harness.2 (B/P) - Ground : Continuity should exist.
LIIA0817E
1 (R) - 6 (R) : Continuity should exist.
1 (R) - ground : Continuity should not exist.
LIIA2258E
2 (L) - Ground : Continuity should exist.
WIIA0603E