BJ:DTC P1094 TUMBLE GENERATED VALVE SIGNAL 1 CIRCUIT MALFUNC-
TION (OPEN)
DTC DETECTING CONDITION:
Immediately at fault recognition
CAUTION:
After repair or replacement of faulty parts, conduct Clear Memory Mode
OPERATION, Clear Memory Mode.> and Inspection Mode
Inspection Mode.>.
WIRING DIAGRAM:
EN-02373
E55 B22
1212
5678
13 14 15 16910 11 12
34
17 18 19 20
E3 E55
B22
B134
895
61
2
B134
56 7
82 1
94 310
24 22 23 25 11 12 13 14 15
26 27
2816 17
18 19 20 21
33 34 29
32 30 31
ECM TUMBLE GENERATOR VALVE
ACTUATOR RH
Page 2226 of 2870

EN(H4DOTC 2.5)-202
ENGINE (DIAGNOSTIC)
Diagnostic Procedure with Diagnostic Trouble Code (DTC)
Step Check Yes No
1 CHECK HARNESS BETWEEN ECM AND
TUMBLE GENERATOR VALVE ACTUATOR
CONNECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the connector from tumble gen-
erator valve and ECM connector.
3) Measure the resistance between tumble
generator valve actuator and ECM connector.
Connector & terminal
(E55) No. 1 — (B134) No. 9:
(E55) No. 2 — (B134) No. 8:Is the resistance less than 1
Ω?Go to step 2.Repair the open
circuit between
ECM and tumble
generator valve
connector.
N
OTE:
In this case repair
the following:
Open circuit in
harness between
ECM and tumble
generator valve
actuator connec-
tor.
Poor contact in
coupling connector
2 CHECK POOR CONTACT.
Check poor contact in tumble generator valve
actuator connector.Is there poor contact in tumble
generator valve actuator con-
nector.Repair the poor
contact in tumble
generator valve
actuator connector.Replace the tum-
ble generator valve
assembly.
FU(H4DOTC 2.5)-
33, Tumble Gener-
ator Valve Assem-
bly.>
Page 2227 of 2870
EN(H4DOTC 2.5)-203
ENGINE (DIAGNOSTIC)
Diagnostic Procedure with Diagnostic Trouble Code (DTC)
BK:DTC P1095 TUMBLE GENERATED VALVE SIGNAL 1 CIRCUIT MALFUNC-
TION (SHORT)
DTC DETECTING CONDITION:
Immediately at fault recognition
CAUTION:
After repair or replacement of faulty parts, conduct Clear Memory Mode
OPERATION, Clear Memory Mode.> and Inspection Mode
Inspection Mode.>.
WIRING DIAGRAM:
EN-02373
E55 B22
1212
5678
13 14 15 16910 11 12
34
17 18 19 20
E3 E55
B22
B134
895
61
2
B134
56 7
82 1
94 310
24 22 23 25 11 12 13 14 15
26 27
2816 17
18 19 20 21
33 34 29
32 30 31
ECM TUMBLE GENERATOR VALVE
ACTUATOR RH
Page 2228 of 2870
EN(H4DOTC 2.5)-204
ENGINE (DIAGNOSTIC)
Diagnostic Procedure with Diagnostic Trouble Code (DTC)
Step Check Yes No
1 CHECK HARNESS BETWEEN ECM AND
TUMBLE GENERATOR VALVE ACTUATOR
CONNECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the connector from tumble gen-
erator valve connector.
3) Measure the voltage between tumble gen-
erator valve actuator and chassis ground.
Connector & terminal
(E55) No. 1 (+) — Chassis ground (
−):
(E55) No. 2 (+) — Chassis ground (
−):Is the voltage less than 5 V? Replace the tum-
ble generator valve
assembly.
FU(H4DOTC 2.5)-
33, Tumble Gener-
ator Valve Assem-
bly.>Repair the battery
short circuit
between ECM and
tumble generator
valve actuator.
Page 2229 of 2870
EN(H4DOTC 2.5)-205
ENGINE (DIAGNOSTIC)
Diagnostic Procedure with Diagnostic Trouble Code (DTC)
BL:DTC P1096 TUMBLE GENERATED VALVE SIGNAL 2 CIRCUIT MALFUNC-
TION (OPEN)
DTC DETECTING CONDITION:
Immediately at fault recognition
CAUTION:
After repair or replacement of faulty parts, conduct Clear Memory Mode
OPERATION, Clear Memory Mode.> and Inspection Mode
Inspection Mode.>.
WIRING DIAGRAM:
EN-02374
E51 B22
1212
5678
13 14 15 16910 11 12
34
17 18 19 20
E3 E51
B22
B134
10118
71
2
B134
56 7
82 1
94 310
24 22 23 25 11 12 13 14 15
26 27
2816 17
18 19 20 21
33 34 29
32 30 31
ECM TUMBLE GENERATOR VALVE
ACTUATOR LH
Page 2230 of 2870

EN(H4DOTC 2.5)-206
ENGINE (DIAGNOSTIC)
Diagnostic Procedure with Diagnostic Trouble Code (DTC)
Step Check Yes No
1 CHECK HARNESS BETWEEN ECM AND
TUMBLE GENERATOR VALVE ACTUATOR
CONNECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the connector from tumble gen-
erator valve and ECM connector.
3) Measure the resistance between tumble
generator valve actuator and ECM connector.
Connector & terminal
(E51) No. 1 — (B134) No. 11:
(E51) No. 2 — (B134) No. 10:Is the resistance less than 1 Ω? Go to step 2.Repair the open
circuit between
ECM and tumble
generator valve
connector.
N
OTE:
In this case repair
the following:
Open circuit in
harness between
ECM and tumble
generator valve
actuator connector.
Poor contact in
coupling connector
2 CHECK POOR CONTACT.
Check poor contact in tumble generator valve
actuator connector.Is there poor contact in tumble
generator valve actuator con-
nector?Repair the poor
contact in tumble
generator valve
actuator connector.Replace the tum-
ble generator valve
assembly.
FU(H4DOTC 2.5)-
33, Tumble Gener-
ator Valve Assem-
bly.>
Page 2231 of 2870
EN(H4DOTC 2.5)-207
ENGINE (DIAGNOSTIC)
Diagnostic Procedure with Diagnostic Trouble Code (DTC)
BM:DTC P1097 TUMBLE GENERATED VALVE SIGNAL 2 CIRCUIT MALFUNC-
TION (SHORT)
DTC DETECTING CONDITION:
Immediately at fault recognition
CAUTION:
After repair or replacement of faulty parts, conduct Clear Memory Mode
OPERATION, Clear Memory Mode.> and Inspection Mode
Inspection Mode.>.
WIRING DIAGRAM:
EN-02374
E51 B22
1212
5678
13 14 15 16910 11 12
34
17 18 19 20
E3 E51
B22
B134
10118
71
2
B134
56 7
82 1
94 310
24 22 23 25 11 12 13 14 15
26 27
2816 17
18 19 20 21
33 34 29
32 30 31
ECM TUMBLE GENERATOR VALVE
ACTUATOR LH
Page 2232 of 2870
EN(H4DOTC 2.5)-208
ENGINE (DIAGNOSTIC)
Diagnostic Procedure with Diagnostic Trouble Code (DTC)
Step Check Yes No
1 CHECK HARNESS BETWEEN ECM AND
TUMBLE GENERATOR VALVE ACTUATOR
CONNECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the connector from tumble gen-
erator valve connector.
3) Measure the voltage between tumble gen-
erator valve actuator and chassis ground.
Connector & terminal
(E51) No. 1 (+) — Chassis ground (
−):
(E51) No. 2 (+) — Chassis ground (
−):Is the voltage less than 5 V? Replace the tum-
ble generator valve
assembly.
FU(H4DOTC 2.5)-
33, Tumble Gener-
ator Valve Assem-
bly.>Repair the battery
short circuit
between ECM and
tumble generator
valve actuator.