Page 3089 of 4402

CHECK\fthe\fturn\fsign\bl\fl\bmps.\f4\b
Is\fthe\fright-h\bnd\fre\br\fturn\fsign\bl\fl\bmp\fon\fcontinuously?\f
Yes\b
LOCATE\f\bnd\fRECTIFY\fthe\fshort\fto\fb\bttery\fvolt\bge\fin\fthe\fcircuit\fbetween\fthe\f
re\br\fl\bmp\f\bssembly\f\bnd\fthe\fSm\brt\fJunction\fBox\fwith\fthe\f\bid\fof\fthe\fWiring\f
Di\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
No\b CHECK\fthe\fSm\brt\fJunction\fBox\f\bnd\fRENEW\fit\fif\frequired.\fCHECK\fsystem\f
oper\btes\fcorrectly\f
E6:\bRULE\bOUT\bTHE\bLEFT-HAND\bDOOR\bCONTROL\bMODULE\bAS\bTHE\bCAUSE\bOF\bTHE\b
FAULT
Ignition\fswitch\fin\fposition\f0.\f1\b
Disconnect\fLeft-h\bnd\fdoor\fcontrol\fmodule\ffrom\fconnector\fC5PL01B.\f2\b
Ignition\fswitch\fin\fposition\fII.\f3\b
CHECK\fthe\fturn\fsign\bl\fl\bmp.\f4\b
Is\fthe\fintegr\bted\fturn\fsign\bl\fl\bmp\fin\fthe\fleft-h\bnd\fexterior\fmirror\fperm\bnently\f
lit?\f
Yes\b
LOCATE\f\bnd\fRECTIFY\fthe\fshort\fto\fb\bttery\fvolt\bge\fin\fthe\fcircuit\fbetween\fthe\f
door\fcontrol\fmodule\f\bnd\fthe\fintegr\bted\fturn\fsign\bl\fl\bmp\fin\fthe\fexterior\f
mirror\fusing\fthe\fWiring\fDi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
No\b
CHECK\f\bnd\fif\fnecess\bry\fRENEW\fthe\fdoor\fcontrol\fmodule.\fCHECK\fsystem\f
oper\btes\fcorrectly\fIf\fthe\fconcern\fpersists:\f\f
REFER\fto:\f Communic\btions\fNetwork \f(418-00\fModule\fCommunic\btions\f
Net
work,\fDi\bgnosis\f\bnd\fTesting).\f
E7:\bRULE\bOUT\bTHE\bRIGHT-HAND\bDOOR\bCONTROL\bMODULE\bAS\bTHE\bCAUSE\bOF\bTHE\b
FAULT
Ignition\fswitch\fin\fposition\f0.\f1\b
Disconnect\fRight-h\bnd\fdoor\fcontrol\fmodule\ffrom\fconnector\fC6PL01B.\f2\b
Ignition\fswitch\fin\fposition\fII.\f3\b
CHECK\fthe\fturn\fsign\bl\fl\bmp.\f4\b
Is\fthe\fintegr\bted\fturn\fsign\bl\fl\bmp\fin\fthe\fright-h\bnd\fexterior\fmirror\fperm\bnently\f
lit?\f
Yes\b
LOCATE\f\bnd\fRECTIFY\fthe\fshort\fto\fb\bttery\fvolt\bge\fin\fthe\fcircuit\fbetween\fthe\f
door\fcontrol\fmodule\f\bnd\fthe\fintegr\bted\fturn\fsign\bl\fl\bmp\fin\fthe\fexterior\f
mirror\fusing\fthe\fWiring\fDi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
No\b CHECK\f\bnd\fif\fnecess\bry\fRENEW\fthe\fdoor\fcontrol\fmodule.\fCHECK\fsystem\f
oper\btes\fcorrectly\fIf\fthe\fconcern\fpersists:\f\f
REFER\fto:\f Communic\btions\fNetwork \f(418-00\fModule\fCommunic\btions\f
Net
work,\fDi\bgnosis\f\bnd\fTesting).\f
Стр. 24 из 24
05.01.2013http://127.0.0.1:8888/wsm/js/procedure.do?variantId=1431&proc-uid=G511717&gui...procarmanuals.com
http://vnx.su
Page 3090 of 4402

Exterior\bLighti\fg\b-\bFog\bLampsS-MAX/G\bl\bxy\f2006.5\f(02/2006-)\fPrint \f
Diag\fosis\ba\fd\bTesti\fg\b
Refer\bto\bWiri\fg\bDiagrams\bSectio\f\b417-01,\bfor\bschematic\ba\fd\bco\f\fector\b
i\f
formatio\f.\b\b
Special\bTool(s)\b
I\fspectio\f\ba\fd\bTesti\fg\b
N O
TE:\fThe\fgeneric\felectronic\fmodule\f(GEM)\fis\fp\brt\fof\ft
he\fcentr\bl\fjunction\fbox\f(CJB).\f
NOTE:\fA\fnew\fGEM\fneeds\fto\fbe\fconfigured\f\bfter\finst\bll\btion.\fFor\fthis\fpurpose,\fthe\fvehicle-
specific\fd\bt\b\f\bre\fre\bd\fout\fof\fthe\fmodule\fto\fbe\fch\bnged\fusing\fWDS\f\bnd\fis\ftr\bnsferred\fto\f
the\fnew\fmodule.\fREFER\fto:\f\f Module\fConfigur\btion \f(
418-01\fModule\fConfigur\btion,\fGener\bl\fProcedures),\f
Generic\fElectronic\fModule\f(GEM) \f(419-10\fMultifunction\fElectronic\fModules,\fDi\bgnosis\f\bn
d\f
Testing).\f
NOTE:\fBefore\fre\bding\fout\fthe\fvehicle-specific\fd\bt\b\fm\bke\fsure\fth\bt\f\bll\felectric\bl\f
co
nnections\fin\fthe\fvehicle\f\bre\freconnected\fso\fth\bt\fthe\fmodule\f\bnd\fWDS\fc\bn\fcommunic\bte\f
correctly.\f
1. 1.\b
Verify\fthe\fcustomer\fconcern.\f
2
. 2.\b
Visu\blly\finspect\ffor\fobvious\fsigns\fof\felectric\bl\fd\bm\bge.\f
V
isual\bI\fspectio\f\bChart\b
3. 3.\b
Resolve\f\bny\fobvious\fc\buses\for\fconcerns\ffound\fduring\fthe\fvisu\bl\finspection\fbefore\f
c
\brrying\fout\f\bny\ffurther\ftests.\f
4. 4.\b
If\fthe\fc\buse\fof\fthe\fconcern\fc\bnnot\fbe\ffound\fby\fvisu\bl\finspection,\fcontinue\fwith\fthe\f
s
ymptom\fch\brt.\f
Symptom\bchart\b
Symptom\bchart\b
Termin\bl\fProbe\fKit\f
29-011A\f
Electric\bl
Fuse(s)\f\f
Bulb(s)\f\f
Connector\f\f
Switch\f\f
Wiring\floom\f
Sym\ftomPossible SourcesAction
The\ffog\fl\bmps\f\bre\finoper\btiveFuse(s)\f
Circuit(s)\f
Lights\fControl\fModule\f
Sm\brt\fJunction\fBox\f
*
*
*
*GO\fto\fPinpoint\fTest\f
A.\f\f
*
One\for\fmore\ffog\fl\bmps\finoper\btiveCircuit(s)\f
Front\ffog\fl\bmps\f
T\bilg\bte\fl\bmps\f\bssembly\f
Sm\brt\fJunction\fBox\f
*
*
*
*GO\fto\fPinpoint\fTest\f
B.\f\f
*
\f
Стр. 1 из 14
05.01.2013http://127.0.0.1:8888/wsm/js/procedure.do?variantId=1431&proc-uid=G511718&gui...procarmanuals.com
http://vnx.su
Page 3091 of 4402

Pi\fpoi\ft\btest\b
NOTE:\fUse\f\b\fdigit\bl\fmultimeter\ffor\f\bll\felectric\bl\fme\bs
urements.\f
The\fFog\fL\bmps\f\bre\fOn\fContinuouslyCircuit(s)\f
Lights\fControl\fModule\f
T\bilg\bte\fl\bmps\f\bssembly\f
Tr\biler\fsocket\f
*
*
*
*GO\fto\fPinpoint\fTest\f
C.\f\f
*
PINPOINT\bTEST\bA\b:\bTHE\bFOG\bLAMPS\bARE\bINOPERATIVE\b
TEST CONDITIONSDETAILS/RESULTS/ACTIONS
A1:\bCHECK\bFUSE\bF33\b(5\bA)\b(EJB)
Ignition\fswitch\fin\fposition\f0.\f1\b
Disconnect\ffuse\fF33\f(5\fA)\f(EJB).\f2\b
CHECK\ffuse\fF33\f(5\fA)\f(EJB).\f3\b
Is\fthe\ffuse\fOK.?\f
Yes\b
GO\fto\fA2.\f\f
No\b
R
ENEW\ffuse\fF33\f(5\fA)\f(EJB)\f\bnd\fCHECK\fthe\f
oper\btion\fof\fthe\fsystem.\fIf\fthe\ffuse\fblows\f\bg\bin,\f
LOCATE\f\bnd\fRECTIFY\fthe\fshort\fto\fground\fusing\fthe\f
Wiring\fDi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
A2:\bCHECK\bTHE\bVOLTAGE\bSUPPLY\bTO\bFUSE\bF33\b(5\bA)\b(EJB)\bFOR\bOPEN\bCIRCUIT
Connect\ffuse\fF33\f(5\fA)\f(EJB).\f1\b
Ignition\fswitch\fin\fposition\fII.\f2\b
Me\bsure\fthe\fvolt\bge\fbetween\ffuse\fF33\f(5\fA)\f(EJB)\f
\bnd\fground.\f3\b
Does\fmeter\fdispl\by\fb\bttery\fvolt\bge?\f
Yes\b GO\fto\fA3.\f\f
No\b
L
OCATE\fAND\fRECTIFY\fthe\fbre\bk\fin\fthe\fvolt\bge\f
supply\fof\ffuse\fF33\f(5\fA)\f(EJB)\fwith\fthe\f\bid\fof\fthe\f
wiring\fdi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
A3:\bCHECK\bFUSE\bF17\b(60\bA)\b(EJB)
Ignition\fswitch\fin\fposition\f0.\f1\b
Disconnect\ffuse\fF17\f(60\fA)\f(EJB).\f2\b
CHECK\ffuse\fF17\f(60\fA)\f(EJB).\f3\b
Is\fthe\ffuse\fOK.?\f
Yes\b GO\fto\fA4.\f\f
No\b R
ENEW\ffuse\fF17\f(60\fA)\f(EJB)\f\bnd\fCHECK\fthe\f
oper\btion\fof\fthe\fsystem.\fIf\fthe\ffuse\fblows\f\bg\bin,\f
LOCATE\f\bnd\fRECTIFY\fthe\fshort\fto\fground\fusing\fthe\f
Wiring\fDi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
A4:\bCHECK\bTHE\bVOLTAGE\bSUPPLY\bTO\bFUSE\bF17\b(60\bA)\b(EJB)\bFOR\bOPEN\bCIRCUIT
Connect\ffuse\fF17\f(60\fA)\f(EJB).\f1\b
Ignition\fswitch\fin\fposition\fII.\f2\b
Me\bsure\fthe\fvolt\bge\fbetween\ffuse\fF17\f(60\fA)\f
(EJB)\f\bnd\fground.\f3\b
Does\fthe\fmeter\fdispl\by\fb\bttery\fvolt\bge?\f
Yes\b GO\fto\fA5.\f\f
No \b
L
OCATE\fAND\fRECTIFY\fthe\fbre\bk\fin\fthe\fvolt\bge\f
supply\fof\ffuse\fF17\f(60\fA)\f(EJB)\fwith\fthe\f\bid\fof\fthe\f
Стр. 2 из 14
05.01.2013http://127.0.0.1:8888/wsm/js/procedure.do?variantId=1431&proc-uid=G511718&gui...procarmanuals.com
http://vnx.su
Page 3092 of 4402

wiring\fdi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
A5:\bCHECK\bFUSE\bF18\b(60\bA)\b(EJB)
Ignition\fswitch\fin\fposition\f0.\f1\b
Disconnect\ffuse\fF18\f(60\fA)\f(EJB).\f2\b
CHECK\ffuse\fF18\f(60\fA)\f(EJB).\f3\b
Is\fthe\ffuse\fOK.?\f
Yes\bGO\fto\fA6.\f\f
No\b R
ENEW\ffuse\fF18\f(60\fA)\f(EJB)\f\bnd\fCHECK\fthe\f
oper\btion\fof\fthe\fsystem.\fIf\fthe\ffuse\fblows\f\bg\bin,\f
LOCATE\f\bnd\fRECTIFY\fthe\fshort\fto\fground\fusing\fthe\f
Wiring\fDi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
A6:\bCHECK\bTHE\bVOLTAGE\bSUPPLY\bTO\bFUSE\bF18\b(60\bA)\b(EJB)\bFOR\bOPEN\bCIRCUIT
Connect\ffuse\fF18\f(60\fA)\f(EJB).\f1\b
Ignition\fswitch\fin\fposition\fII.\f2\b
Me\bsure\fthe\fvolt\bge\fbetween\ffuse\fF18\f(60\fA)\f
(EJB)\f\bnd\fground.\f3\b
Does\fthe\fmeter\fdispl\by\fb\bttery\fvolt\bge?\f
Yes\b
GO\fto\fA7.\f\f
No\b L
OCATE\fAND\fRECTIFY\fthe\fbre\bk\fin\fthe\fvolt\bge\f
supply\fof\ffuse\fF18\f(60\fA)\f(EJB)\fwith\fthe\f\bid\fof\fthe\f
wiring\fdi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
A7:\bCHECK\bTHE\bVOLTAGE\bSUPPLY\bTO\bTHE\bLIGHTS\bCONTROL\bMODULE\bFOR\bOPEN\b
CIRCUIT
Ignition\fswitch\fin\fposition\f0.\f1\b
Disconnect\fLights\fcontrol\fmodule\ffrom\fconnector\f
C2LF23D.\f2\b
Ignition\fswitch\fin\fposition\fII.\f3\b
Me\bsure\fthe\fvolt\bge\fbetween\fthe\flights\fcontrol\f
module,\fconnector\fC2LF23D,\fpin\f1,\fcircuit\fSBB33B\f
(RD),\fwiring\fh\brness\fside\f\bnd\fground.\f4\b
Does\fthe\fmeter\fdispl\by\fb\bttery\fvolt\bge?\f
Yes\b
GO\fto\fA8.\f\f
No\b L
OCATE\f\bnd\fRECTIFY\fthe\fbre\bk\fin\fthe\fcircuits\f
between\ffuse\fF33\f(5\fA)\f(EJB)\f\bnd\fthe\flights\fcontrol\f
module\fwith\fthe\f\bid\fof\fthe\fwiring\fdi\bgr\bms.\fCHECK\f
system\foper\btes\fcorrectly\f
A8:\bCHECK\bTHE\bGROUND\bCONNECTION\bOF\bTHE\bLIGHTS\bCONTROL\bMODULE\bFOR\bOPEN\b
CIRCUIT
Ignition\fswitch\fin\fposition\f0.\f1\b
Me\bsure\fthe\fresist\bnce\fbetween\fthe\flights\fcontrol\f
module,\fconnector\fC2LS23D,\fpin\f5,\fcircuit\f
GD133BT\f(BK),\fwiring\fh\brness\fside\f\bnd\fground.\f2\b
\f\f
Стр. 3 из 14
05.01.2013http://127.0.0.1:8888/wsm/js/procedure.do?variantId=1431&proc-uid=G511718&gui...procarmanuals.com
http://vnx.su
Page 3093 of 4402

Is\f\b\fresist\bnce\fof\fless\fth\bn\f2\fOhm\fregistered?\f
Yes\bGO\fto\fA9.\f\f
No \b
L
OCATE\f\bnd\fRECTIFY\fthe\fbre\bk\fin\fthe\fcircuits\f
between\fthe\flights\fcontrol\fmodule\f\bnd\fsoldered\f
connection\fSP581\fwith\fthe\f\bid\fof\fthe\fWiring\f
Di\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
A9:\bRULE\bOUT\bTHE\bLIGHTS\bCONTROL\bMODULE\bAS\bA\bPOSSIBLE\bCAUSE\bOF\bTHE\bFAULT
CHECK\fthe\flights\fcontrol\fmodule.\f1\b
Is\fthe\flights\fcontrol\fmodule\fOK?\f
Yes\b GO\fto\fA10 .\f\f
No\b I
NSTALL\fA\fNEW\flights\fcontrol\fmodule.\fCHECK\f
system\foper\btes\fcorrectly\f
A10:\bCHECK\bTHE\bVOLTAGE\bSUPPLY\bTO\bTHE\bSMART\bJUNCTION\bBOX\bFOR\bOPEN\b
CIRCUIT
Disconnect\fSm\brt\fJunction\fBox\ffrom\fconnector\f
C1BP02G.\f1\b
Ignition\fswitch\fin\fposition\fII.\f2\b
Me\bsure\fthe\fvolt\bge\fbetween\fthe\fSm\brt\fJunction\f
Box,\fconnector\fC1BP02G,\fpin\f1,\fcircuit\fSBB17A\f
(RD),\fwiring\fh\brness\fside\f\bnd\fground.\f3\b
Does\fthe\fmeter\fdispl\by\fb\bttery\fvolt\bge?\f
Yes\b GO\fto\fA11 .\f\f
No\b
L
OCATE\f\bnd\fRECTIFY\fthe\fbre\bk\fin\fthe\fcircuits\f
between\ffuse\fF17\f(60\fA)\f(EJB)\f\bnd\fthe\fSm\brt\f
Junction\fBox\fwith\fthe\f\bid\fof\fthe\fwiring\fdi\bgr\bms.\f
CHECK\fsystem\foper\btes\fcorrectly\f
A11:\bCHECK\bTHE\bVOLTAGE\bSUPPLY\bTO\bTHE\bSMART\bJUNCTION\bBOX\bFOR\bOPEN\b
CIRCUIT
Me\bsure\fthe\fvolt\bge\fbetween\fthe\fSm\brt\fJunction\f
Box,\fconnector\fC1BP02G,\fpin\f2,\fcircuit\fSBB18A\f
(YE),\fwiring\fh\brness\fside\f\bnd\fground.\f1\b
\f\f
\f\f
Стр. 4 из 14
05.01.2013http://127.0.0.1:8888/wsm/js/procedure.do?variantId=1431&proc-uid=G511718&gui...procarmanuals.com
http://vnx.su
Page 3094 of 4402

Does\fthe\fmeter\fdispl\by\fb\bttery\fvolt\bge?\f
Yes\bGO\fto\fA12 .\f\f
No \b
L
OCATE\f\bnd\fRECTIFY\fthe\fbre\bk\fin\fthe\fcircuits\f
between\ffuse\fF18\f(60\fA)\f(EJB)\f\bnd\fthe\fSm\brt\f
Junction\fBox\fwith\fthe\f\bid\fof\fthe\fwiring\fdi\bgr\bms.\f
CHECK\fsystem\foper\btes\fcorrectly\f
A12:\bCHECK\bTHE\bGROUND\bCONNECTION\bTO\bTHE\bSMART\bJUNCTION\bBOX\bFOR\bOPEN\b
CIRCUIT
Ignition\fswitch\fin\fposition\f0.\f1\b
Disconnect\fSm\brt\fJunction\fBox\ffrom\fconnector\f
C1BP02A.\f2\b
Me\bsure\fthe\fresist\bnce\fbetween\fthe\fSm\brt\f
Junction\fBox,\fconnector\fC1BP02A,\fpin\f54,\fwiring\f
h\brness\fside\fGD123F\f(BK/GY)\f\bnd\fground.\f3\b
Is\f\b\fresist\bnce\fof\fless\fth\bn\f2\fOhm\fregistered?\f
Yes\b GO\fto\fA13 .\f\f
No\b L
OCATE\f\bnd\fRECTIFY\fthe\fbre\bk\fin\fthe\fcircuits\f
between\fthe\fSm\brt\fJunction\fBox\f\bnd\fground\fwith\f
the\f\bid\fof\fthe\fWiring\fDi\bgr\bms.\fCHECK\fsystem\f
oper\btes\fcorrectly\f
A13:\bCHECK\bTHE\bGROUND\bCONNECTION\bTO\bTHE\bSMART\bJUNCTION\bBOX\bFOR\bOPEN\b
CIRCUIT
Disconnect\fSm\brt\fJunction\fBox\ffrom\fconnector\f
C1BP02B.\f1\b
Me\bsure\fthe\fresist\bnce\fbetween\fthe\flights\fcontrol\f
module,\fconnector\fC1BP02B,\fpin\f65:\f
LHD:\fcircuit\fGD140J\f(BK/GN),\fwiring\fh\brness\f
si
de\f\bnd\fground.\f
RHD:\fcircuit\fGD134U\f(BK/VT),\fwiring\fh\brness\f
si
de\f\bnd\fground.\f
2\b
Is\f\b\fresist\bnce\fof\fless\fth\bn\f2\fOhm\fregistered?\f
Yes\b GO\fto\fA14 .\f\f
No \b
\f
\f
\f\f
Стр. 5 из
14
05.01.2013http://127.0.0.1:8888/wsm/js/procedure.do?variantId=1431&proc-uid=G511718&gui...procarmanuals.com
http://vnx.su
Page 3095 of 4402

-\fLHD:\fLOCATE\fAND\fRECTIFY\fthe\fbre\bk\fin\fthe\f
circuits\fbetween\fthe\flights\fcontrol\fmodule\f\bnd\f
ground\fconnection\fG3D138\fwith\fthe\f\bid\fof\fthe\f
Wiring\fDi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly
\f
-\fRHD:\fLOCATE\fAND\fRECTIFY\fthe\fbre\bk\fin\fthe\f
circuits\fbetween\fthe\flights\fcontrol\fmodule\f\bnd\f
ground\fconnection\fG3D133\fwith\fthe\f\bid\fof\fthe\f
Wiring\fDi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly
\f
A14:\bCHECK\bTHE\bLIN\bDATA\bBUS\bCONNECTION\bBETWEEN\bTHE\bLIGHTS\bCONTROL\b
MODULE\bAND\bTHE\bSMART\bJUNCTION\bBOX\bFOR\bSHORT\bCIRCUIT\bTO\bBATTERY\bVOLTAGE
Ignition\fswitch\fin\fposition\fII.\f1\b
Me\bsure\fthe\fvolt\bge\fbetween\fthe\flights\fcontrol\f
module,\fconnector\fC2LF23D,\fpin\f6,\fcircuit\fVLF25A\f
(GN/VT),\fwiring\fh\brness\fside\f\bnd\fground.\f2\b
Does\fthe\fmeter\fdispl\by\fb\bttery\fvolt\bge?\f
Yes\b GO\fto\fA15 .\f\f
No\b L
OCATE\f\bnd\fRECTIFY\fthe\fshort\fto\fb\bttery\fvolt\bge\f
in\fthe\fcircuits\fbetween\fthe\flights\fcontrol\fmodule\f
\bnd\fthe\fSm\brt\fJunction\fBox\fwith\fthe\f\bid\fof\fthe\f
wiring\fdi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
A15:\bCHECK\bTHE\bLIN\bDATA\bBUS\bCONNECTION\bBETWEEN\bTHE\bLIGHTS\bCONTROL\b
MODULE\bAND\bTHE\bSMART\bJUNCTION\bBOX\bFOR\bSHORT\bCIRCUIT\bTO\bGROUND
Ignition\fswitch\fin\fposition\f0.\f1\b
Me\bsure\fthe\fresist\bnce\fbetween\fthe\flights\fcontrol\f
module,\fconnector\fC2LF23D,\fpin\f6,\fcircuit\fVLF25A\f
(GN/VT),\fwiring\fh\brness\fside\f\bnd\fground.\f2\b
Is\f\b\fresist\bnce\fof\fmore\fth\bn\f10,000\fOhm\fme\bsured?\f
Yes\b GO\fto\fA16 .\f\f
No\b L
OCATE\f\bnd\fRECTIFY\fthe\fshort\fto\fground\fin\fthe\f
circuits\fbetween\fthe\flights\fcontrol\fmodule\f\bnd\fthe\f
Sm\brt\fJunction\fBox\fwith\fthe\f\bid\fof\fthe\fwiring\f
di\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
A16:\bCHECK\bTHE\bLIN\bDATA\bBUS\bCONNECTION\bBETWEEN\bTHE\bLIGHTS\bCONTROL\b
MODULE\bAND\bTHE\bSMART\bJUNCTION\bBOX\bFOR\bOPEN\bCIRCUIT
Disconnect\fSm\brt\fJunction\fBox\ffrom\fconnector\f
C1BP02C.\f1\b
Me\bsure\fthe\fresist\bnce\fbetween\fthe\flights\fcontrol\f
module,\fconnector\fC2LF23D,\fpin\f6,\fcircuit\fVLF25A\f
(GN/VT),\fwiring\fh\brness\fside\f\bnd\fthe\fSm\brt\f
Junction\fBox,\fconnector\fC1BP02C,\fpin\f52,\fcircuit\f2\b
\f\f
\f\f
Стр. 6 из 14
05.01.2013http://127.0.0.1:8888/wsm/js/procedure.do?variantId=1431&proc-uid=G511718&gui...procarmanuals.com
http://vnx.su
Page 3096 of 4402

VLF25A\f(GN/VT),\fwiring\fh\brness\fside.\f
Is\f\b\fresist\bnce\fof\fless\fth\bn\f2\fOhm\fregistered?\f
Yes\b
CHECK\fthe\fSm\brt\fJunction\fBox\f\bnd\fINSTALL\fA\fNEW\f
ONE\fif\frequired.\fCHECK\fsystem\foper\btes\fcorrectly\f
If\fthe\fconcern\fpersists:\f\f
REFER\fto:\fCommunic\btions\fNetwork \f(418-00\f
Mod
ule\fCommunic\btions\fNetwork,\fDi\bgnosis\f\bnd\f
Testing).\f
No\b
LOCATE\f\bnd\fRECTIFY\fthe\fopen\fcircuit\fin\fthe\fcircuits\f
between\fthe\flights\fcontrol\fmodule\f\bnd\fthe\fSm\brt\f
Junction\fBox\fwith\fthe\f\bid\fof\fthe\fwiring\fdi\bgr\bms.\f
PINPOINT\bTEST\bB\b:\bINDIVIDUAL\bOR\bMULTIPLE\bFOG\bLAMPS\bINOPERATIVE\b
TEST CONDITIONSDETAILS/RESULTS/ACTIONS
B1:\bDETERMINE\bCONDITIONS\bUNDER\bWHICH\bTHE\bFAULT\bOCCURS
Ignition\fswitch\fin\fposition\fII.\f1\b
SWITCH\fON\fthe\ffront\f\bnd\fre\br\ffog\fl\bmps.\f2\b
CHECK\ffog\fl\bmps.\f3\b
Are\fone\for\fmore\ffront\ffog\fl\bmps\finoper\btive?\f
Yes\b -\fLeft-h\bnd\ffront\ffog\fl\bmp\finoper\btive:\f GO\fto\fB4.\f\f
-\fR
ight-h\bnd\ffront\ffog\fl\bmp\finoper\btive:\f GO\fto\fB7.\f
\f
-\fBoth\ffront\ffog\fl\bmps\finoper\btive:\f GO\fto\fB2.\f\f
No\b
-
\fLeft-h\bnd\fre\br\ffog\fl\bmp\finoper\btive:\f GO\fto\fB11.\f\f
-\fR
ight-h\bnd\fre\br\ffog\fl\bmp\finoper\btive:\f GO\fto\fB14.\f
-\fB
oth\fre\br\ffog\fl\bmps\finoper\btive:\f GO\fto\fB10.\f\f
B2:\bCHECK\bFUSE\bF13\b(15\bA)\b(SJB)
Ignition\fswitch\fin\fposition\f0.\f1\b
Disconnect\fFuse\fF13\f(15\fA)\f(SJB).\f2\b
CHECK\fFuse\fF13\f(15\fA)\f(SJB).\f3\b
Is\fthe\ffuse\fOK.?\f
Yes\b
GO\fto\fB3.\f\f
No\b
R
ENEW\ffuse\fF13\f(15\fA)\f(SJB)\f\bnd\fCHECK\fthe\f
oper\btion\fof\fthe\fsystem.\fIf\fthe\ffuse\fblows\f\bg\bin,\f
LOCATE\f\bnd\fRECTIFY\fthe\fshort\fto\fground\fusing\fthe\f
Wiring\fDi\bgr\bms.\fCHECK\fsystem\foper\btes\fcorrectly\f
B3:\bCHECK\bTHE\bVOLTAGE\bSUPPLY\bTO\bFUSE\bF13\b(15\bA)\b(SJB)\bFOR\bOPEN\bCIRCUIT
Connect\fFuse\fF13\f(15\fA)\f(SJB).\f1\b
Ignition\fswitch\fin\fposition\fII.\f2\b
Me\bsure\fthe\fvolt\bge\fbetween\ffuse\fF13\f(15\fA)\f
(SJB)\f\bnd\fground.\f3\b
Does\fmeter\fdispl\by\fb\bttery\fvolt\bge?\f
Yes\b
\f\f
Стр. 7 из
14
05.01.2013http://127.0.0.1:8888/wsm/js/procedure.do?variantId=1431&proc-uid=G511718&gui...procarmanuals.com
http://vnx.su