2008 INFINITI FX35 Service Manual

Page 1457 of 3924

INFINITI FX35 2008  Service Manual 
DTC P0130, P0150 A/F SENSOR 1
EC-217
< SERVICE INFORMATION > [VQ35DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagno

Page 1458 of 3924

INFINITI FX35 2008  Service Manual 
EC-218
< SERVICE INFORMATION >[VQ35DE]
DTC P0130, P0150 
A/F SENSOR 1
3. Check voltage between air fuel ratio (A/F) sensor 1 terminal 3
and ground with CONSULT-III or tester.
OK or NG
OK >> GO TO 4.

Page 1459 of 3924

INFINITI FX35 2008  Service Manual 
DTC P0130, P0150 A/F SENSOR 1
EC-219
< SERVICE INFORMATION > [VQ35DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK

Page 1460 of 3924

INFINITI FX35 2008  Service Manual 
EC-220
< SERVICE INFORMATION >[VQ35DE]
DTC P0131, P0151 
A/F SENSOR 1
DTC P0131, P0151 A/F SENSOR 1
Component DescriptionINFOID:0000000001326053
The air fuel ratio (A/F) sensor is a planar dual-cell

Page 1461 of 3924

INFINITI FX35 2008  Service Manual 
DTC P0131, P0151 A/F SENSOR 1
EC-221
< SERVICE INFORMATION > [VQ35DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
3. Check “A/F SEN1 (B1)” or “A/F SEN1 (B2)” indication.
If the indication is constantly a

Page 1462 of 3924

INFINITI FX35 2008  Service Manual 
EC-222
< SERVICE INFORMATION >[VQ35DE]
DTC P0131, P0151 
A/F SENSOR 1
Wiring Diagram
INFOID:0000000001326057
BANK 1
Specification data are reference values and are measured between each terminal and

Page 1463 of 3924

INFINITI FX35 2008  Service Manual 
DTC P0131, P0151 A/F SENSOR 1
EC-223
< SERVICE INFORMATION > [VQ35DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Do not use ECM ground terminals wh
en measuring input/output voltage. Doing so may result in dam-

Page 1464 of 3924

INFINITI FX35 2008  Service Manual 
EC-224
< SERVICE INFORMATION >[VQ35DE]
DTC P0131, P0151 
A/F SENSOR 1
BANK 2
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CON