1998 JAGUAR X308 Workshop Manual

Page 537 of 2490

JAGUAR X308 1998 2.G Workshop Manual  R
emove fuse F12 
1 
W

ith EM015, EM014, PI031 or (PI032) disconnected, 
measure the voltage between EM015/009 (EM015/008) 
and EM014/009 
2 
0 V?
  
Yes  Reconnect EM015 and EM0 14 and replace fuse

Page 538 of 2490

JAGUAR X308 1998 2.G Workshop Manual  Measure
  the voltage between PI031/002 (PI032/002) and
 
ground EM016L 
1 
B+ ? 
Yes  
GO to  B5  
No
  
Inspect EM020/010, PI001, PI031 (PI032) for bent / 
pushed back pins or locate  and repair ha

Page 539 of 2490

JAGUAR X308 1998 2.G Workshop Manual W
ith EM015 and EM014 disconnected, measure the 
insulation resistance between EM015/009 (EM015/008) 
and ground EM014/009 
1 
I
 s the resistance > 10 MOHM? 
Yes  Do not reconnect 
GO to  B6  
No  In

Page 540 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test C: P1396 
 VVT solenoid malfunction 
 W
i
 th EM015, EM014 PI031 and PI032 disconnected, 
measure the insulation resistance between EM015/009 
and EM015/008 
1 
I s
  the resistance > 10

Page 541 of 2490

JAGUAR X308 1998 2.G Workshop Manual  Conne
ct the scan tool 
1 
Have the DTC(s) and fr

eeze 
frame data been recorded? 
Yes  GO to  C2  
C2
 : CHECK VVT COIL CONTINUITY
 Wi

th VVT connector PI032 disconnected, measure the 
resistance

Page 542 of 2490

JAGUAR X308 1998 2.G Workshop Manual Re
 move fuse F12 
1 
W
i
 th EM015, EM014, PI031 and PI032 disconnected, 
measure the voltage between EM015/008 and 
EM014/009 
2 
0 V?  
Yes
  
Reconnect EM015 and EM0 14 and replace fuse F12 
GO to

Page 543 of 2490

JAGUAR X308 1998 2.G Workshop Manual  Me
asure the voltage between PI032/002 and ground 
EM016L 
1 
B+ ? 
Yes
  
GO to  C5  
No  Inspect EM020/010 PI031 (PI032) for bent / pushed back 
pins or locate and repair harness / splice PIS06. 
C

Page 544 of 2490

JAGUAR X308 1998 2.G Workshop Manual Wi
 th EM015 and EM014 disconnected, measure the 
insulation resistance between EM015/008 and ground 
EM014/009 
1 
Is
  the resistance > 10 MOHM? 
Yes  Do not reconnect 
GO to  C6  
No  Inspect EM015