1998 JAGUAR X308 Workshop Manual

Page 1529 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
Parts List 
Operation 
ItemPart NumberDescription
1—Heated oxygen sensor (upstream) 
2—Oxygen sensor (downstream) 
3—Catalytic converter

Page 1530 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
The upstream heated oxygen sensor is located at the catalytic converter inlet and detects the concentration of oxygen in the
 raw exhaust gases; an internal  heater reduces the warm up time of the s

Page 1531 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
Inspection and Verification 
Vehicle Harness Check 
1.1. Check for open and short circuit in harness conn ector faults between the O2 sensor and ECM. 
2. 2. Check for approximately 12V  between heat

Page 1532 of 2490

JAGUAR X308 1998 2.G Workshop Manual Heater Resistance Check 
1.1. Verify that the resistance between the heater term inals is between 4OHM and 10OHM at -20°C to 100°C. 
Performance Check 
1.1. Run the engine at 2500 RPM for two minute

Page 1533 of 2490

JAGUAR X308 1998 2.G Workshop Manual Exhaust System - Exhaust System 
Diagnosis and Testing 
Symptom Chart 
Symptom Chart 
Special Tool(s)
 
Digital multimeter 
 
Generic scantool 
SymptomPossible SourcesAction
DTC P0420 Catalyst system

Page 1534 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test A: P0131, P0132, P0135 
between connections. ECM failure 
*
DTC P0140 O2 sensor circuit no activity detected 
(Bank 1 sensor 2)O2 sensor failure / out of spec 
Sensor ground fault 
Harne

Page 1535 of 2490

JAGUAR X308 1998 2.G Workshop Manual  Connect the scan tool 1 
Have the DTC(s) and freeze frame data been recorded? 
Yes  GO to A2  
A2: CHECK O2 SENSOR HEATER CONTINUITY
 Ignition switch to position 0 1 
Disconnect EM021 
Bracket on

Page 1536 of 2490

JAGUAR X308 1998 2.G Workshop Manual Bracket on top of gearbox or Bulkhead rear of engine  
With EM021 disconnected, measure the voltage between 
EM021/003 and EM021/004. 3 
Is the voltage between 600mV and 1.0 Volt? 
Yes 
GO to A4