Page 993 of 2389
REMOVAL OF WATER PUMP
1. DRAIN ENGINE COOLANT (See page CO±4)
2. DISCONNECT WATER TEMPERATURE SWITCH
CONNECTOR
3. DISCONNECT RADIATOR LOWER HOSE FROM
WATER INLET HOUSING
4. REMOVE TIMING BELT, PULLEYS
(See pages EM±23 to 26)
5. REMOVE WATER PUMP AND WATER PUMP COVER
ASSEMBLY .
(a) Remove the two nuts holding the pump to the water by±
pass pipe.
WATER PUMP (3S±FE)
COMPONENTS
± COOLING SYSTEMWater Pump (3S±FE)CO±6
Page 994 of 2389
INSTALLATION OF WATER PUMP
(See page CO±6)
1. ASSEMBLE WATER PUMP AND WATER PUMP COVER
Install anew gasket and the pump to the pump cover with the
three bolts.
Torque: 90 kg±cm (78 in.±Ib, 8.8 N±m)
INSPECTION OF WATER PUMP
INSPECT WATER PUMP
Turn the pulley and check that the water pump bearing
moves smoothly and quietly.
2. INSTALL WATER PUMP AND WATER PUMP COVER
ASSEMBLY
(a) Install two new 0±rings and gasket to the pump cover and wa-
ter by±pass pipe. 6. DISASSEMBLE WATER PUMP AND WATER PUMP
COVER
Remove the three bolts, water pump and gasket from the
pump cover. (b) Remove the three bolts in the sequence shown.
(c) Pull out the water pump together with pump cover.
(d) Remove the two Q±rings and gasket.
± COOLING SYSTEMwater Pump (3S±FE)CO±7
Page 995 of 2389
(b) Apply a fight coat of engine oil on the 4±ring of the water
by±pass pipe.
(c) Connect the pump cover to the water by±pass pipe. Do
not install the nuts yet.
(d) Install the water pump with the three bolts. Torque the
bolts in the sequence shown.
Torque: 95 kg±cm (82 in.±Ib, 9.3 N±m)
3. INSTALL PULLEYS AND TIMING BELT (See pages
EM±29 to 33)
4. CONNECT RADIATOR LOWER HOSE
5. CONNECT WATER TEMPERATURE SWITCH
CONNECTOR
6. FILL WITH ENGINE COOLANT (See page CO±5) (e) Install the two nuts holding the pump cover to the water
by±pass pipe.
Torque: 95 kg±cm (82 in.±Ib, 9.3 N±m)
± COOLING SYSTEMWater Pump PS±FE)CO±8
Page 996 of 2389
REMOVAL OF WATER PUMP
1. DRAIN ENGINE COOLANT (See page CO±5)
2. DISCONNECT RADIATOR LOWER NOSE FROM
WATER INLET PIPE
3. DISCONNECT TIMING BELT FROM WATER PUMP
PULLEY (See pages EM±34 to 39)
4. REMOVE WATER INLET PIPE
(a) Remove the bolt holding the water inlet pipe to the alternator
belt adjusting bar.
(b) Remove the water inlet pipe and 0±ring.
5. REMOVE WATER INLET AND THERMOSTAT
(See steps 4 and 5 on page CO±13)
WATER PUMP(2VZ±FE)
COMPONENTS
± COOLING SYSTEMWater Pump (2VZ±FE)CO±9
Page 997 of 2389

INSTALLATION OF WATER PUMP
(See page CO±9)
1. INSTALL WATER PUMP
(a) Remove any old packing (FIPG) material and be careful not
to drop any oil on the contact surfaces of the water pump
and cylinder block.
wUsing a razor blade and gasket scraper, remove all
the old packing (FIPG) material from the gasket surfaces
and sealing groove.
wThoroughly clean all components to remove all the loose
material.
wUsing a non±residue solvent, clean both sealing surfaces.
(b) Apply seal packing to the water pump groove.
Seal packing: Part No.08826±00100 or equivalent
wInstall a nozzle that has been cut to a 2 ± 3 mm
(0.08 ± 0.12 in.) opening.
HINT: Avoid applying an excessive amount to the surface.
wParts must be assembled within 5 minutes of application.
Otherwise the material must be removed and reapplied.
wImmediately remove nozzle from the tube and reinstall cap.
(c) Install the water pump with the seven bolts.
Torque: 200 kg±cm (14 ft±lb, 20 N±m)
2. INSTALL WATER INLET AND THERMOSTAT
(See steps 1 and 2 on page CO±13) 6. REMOVE WATER PUMP
(a) Remove the seven bolts.
(b) Remove the water pump by prying a screwdriver between
the water pump and cylinder block.
INSPECTION OF WATER PUMP
INSPECT WATER PUMP
Turn the pulley and check that the water pump bearing
moves smoothly and quietly.
± COOLING SYSTEMWater Pump (2VZ±FE)CO±10
Page 998 of 2389
3. INSTALL WATER INLET PIPE
(a) Install a new 0±ring to the water inlet pipe.
(b) Apply soapy water to the O±ring.
(c) Connect the water inlet pipe to the water inlet.
(d) Install the bolt holding the water inlet pipe to the alternator
belt adjusting bar.
Torque: 200 kg±cm (14 ft±Ib, 20 N±m)
4. INSTALL TIMING BELT (See pages EM±42 to 46)
5. CONNECT RADIATOR LOWER HOSE
6. FILL WITH ENGINE COOLANT (See page CO±5)
± COOLING SYSTEMWater Pump (2VZ±FE)CO±11
Page 999 of 2389

THERMOSTAT (3S±FE)
REMOVAL OF THERMOSTAT
1. DRAIN ENGINE COOLANT (See page CO±4)
2. DISCONNECT WATER TEMPERATURE SWITCH
CONNECTOR
3. DISCONNECT RADIATOR FROM WATER INLET
HOUSING
4. REMOVE WATER INLET HOUSING
Remove the two nuts and water inlet housing from the
waterpump.
5. REMOVE THERMOSTAT AND GASKET
INSPECTION OF THERMOSTAT
INSPECT THERMOSTAT
HINT: The thermostat is numbered with the valve opening
temperature.
(a) Immerse the thermostat in water and gradually heat the wa-
ter.
(b) Check the valve opening temperature.
Valve opening temperature:
80 ± 845C (176 ± 1835F)
If the valve opening temperature is not as specified, re-
place the thermostat.
(e) Check the valve lift.
Valve lift:
8 mm (0.31 in.) or more at 95°C (203°F)
If the valve lift is less than specification, replace the
thermostat.
INSTALLATION OF THERMOSTAT
1. PLACE THERMOSTAT IN WATER INLET HOUSING
(a) Install a new gasket to the thermostat.
(b) Align the jiggle valve of the thermostat with protrusion of the
water inlet housing and, insert the thermostat in the water
inlet housing.
2. INSTALL WATER INLET HOUSING AND THERMOSTAT
ASSEMBLY
Install the water inlet housing and thermostat assembly with
the two nuts.
Torque: 90 kg±cm (78 in.±Ib, 8.8 N±m)
3. CONNECT RADIATOR LOWER HOSE
4. CONNECT WATER TEMPERATURE SWITCH
CONNECTOR
5. FILL WITH ENGINE COOLANT (See page CO±5)
6. START ENGINE AND CHECK FOR LEAKS
± COOLING SYSTEMThermostat (3S±FE)CO±12
Page 1000 of 2389
(b) Check the valve opening temperature
Valve opening temperature:
80 ± 845C (176 ± 1835F)
If the valve opening temperature is not as specified, re-
place the thermostat.
(c) Check the valve lift.
Valve lift:
8.5 mm (0.335 in.) or more at 95
°C (203°F)
If the valve lift is less than specification, replace the ther-
mostat.
(d) Check that the valve spring is tight when the thermostat
is fully closed.
THERMOSTAT (2VZ±FE)
REMOVAL OF THERMOSTAT
1. DRAIN ENGINE COOLANT (See page CO±5)
2. REMOVE WATER INLET PIPE
(See steps 2 and 4 on page CO±9)
3. DISCONNECT WATER TEMPERATURE SENSOR
CONNECTOR
INSPECTION OF THERMOSTAT
INSPECT THERMOSTAT
HINT: The thermostat is numbered with the valve opening
temperature.
(a) Immerse the thermostat in water and gradually heat the wa-
ter. 4. REMOVE WATER INLET
Remove the three nuts and water inlet from the water
pump.
5. REMOVE THERMOSTAT AND GASKET
± COOLING SYSTEMThermostat (2VZ±FE)CO±13