2001 NISSAN ALMERA N16 Electronic Repair Manual

Page 849 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual Major Sensor Reference Graph in Data Monitor
Mode
=NJEC0635The following are the major sensor reference graphs in ªDATA MONITORº mode.
ACCEL POS SEN, ªCKPS´RPM (TDC)º, ªMAS AIR/FL SEºNJEC0635S0

Page 850 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual SEF289H
ECM Terminals and Reference ValueNJEC0636PREPARATIONNJEC0636S01ECM is locating beside of blower unit.
1. Remove the ECM bracket fixing.
2. Remove ECM harness protector.
3. Disconnect negative

Page 851 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual TERMI-
NAL
NO.WIRE
COLORITEM CONDITIONDATA (DC Voltage and Pulse
Signal)
204 L Air conditioner relay[Engine is running]
+Air conditioner switch is ªOFFºBATTERY VOLTAGE
(11 - 14V)
[Engine is running]

Page 852 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual TERMI-
NAL
NO.WIRE
COLORITEM CONDITIONDATA (DC Voltage and Pulse
Signal)
337
338
350
351W/L
PU/W
GY
OR/BEGR volume control
valve[Engine is running]
+Warm-up condition
+Idle speed0.1 - 14V
(Voltage sig

Page 853 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual TERMI-
NAL
NO.WIRE
COLORITEM CONDITIONDATA (DC Voltage and Pulse
Signal)
417 PU/R Vehicle speed sensor[Engine is running]
+Lift up the vehicle
+In 1st gear position
+Vehicle speed is 10 km/h (6 MPH)0

Page 854 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual TERMI-
NAL
NO.WIRE
COLORITEM CONDITIONDATA (DC Voltage and Pulse
Signal)
439 L/OR Tachometer[Engine is running]
+Warm-up condition
+Idle speedApproximately 4.8V
SEF325Y
[Engine is running]
+Warm-up co

Page 855 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual DescriptionNJEC0637Intermittent incidents (I/I) may occur. In many cases, the problem resolves itself (the part or circuit function
returns to normal without intervention). It is important to realize

Page 856 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual Main Power Supply and Ground Circuit
ECM TERMINALS AND REFERENCE VALUENJEC0639Remarks: Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use EC