Page 3297 of 4210
THIRD ROW POWER FOLDING SEAT CONTROL UNITSE-25
< ECU DIAGNOSIS >
C
DE
F
G H
I
K L
M A
B
SE
N
O P
ABJIA0088GB
Revision: April 20092010 QX56
Page 3298 of 4210
SE-26
< ECU DIAGNOSIS >
THIRD ROW POWER FOLDING SEAT CONTROL UNIT
ABJIA0089GB
Revision: April 20092010 QX56
Page 3299 of 4210
THIRD ROW POWER FOLDING SEAT CONTROL UNITSE-27
< ECU DIAGNOSIS >
C
DE
F
G H
I
K L
M A
B
SE
N
O P
ABJIA0090GB
Revision: April 20092010 QX56
Page 3300 of 4210
SE-28
< ECU DIAGNOSIS >
THIRD ROW POWER FOLDING SEAT CONTROL UNIT
ABJIA0308GB
Revision: April 20092010 QX56
Page 3301 of 4210
THIRD ROW POWER FOLDING SEAT CONTROL UNITSE-29
< ECU DIAGNOSIS >
C
DE
F
G H
I
K L
M A
B
SE
N
O P
DTC IndexINFOID:0000000005147392
NOTE:
To initiate a chime code sequence cycle, turn the ignition switch ON and OFF 3 times within 5 seconds. The
first digit will chime, then a pause, followed by the sec ond digit. For example, a code 13 will have 1 chime, fol-
lowed by a pause, and then 3 chimes. The third row pow er folding seat control unit will clear all codes that
have been corrected after 255 ignition cycles.
ABJIA0309GB
Revision: April 20092010 QX56
Page 3302 of 4210

SE-30
< ECU DIAGNOSIS >
THIRD ROW POWER FOLDING SEAT CONTROL UNIT
Fail Safe
INFOID:0000000005147393
The third row power folding seat will not operate under the following conditions:
• Power supply to the third row power folding seat control unit falls below 9.0V
• One of the third row power foldi ng seat switches is stuck closed
• The A/T selector lever is not in PARK position and the ignition switch is ON
DTCMalfunction Service Procedure
11 LH seat has traveled past normal fold
down position 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Check third row power folding seat motor LH Hall signal and ground circuits. Refer to SE-37, "
Third Row Power
Folding Seat Stops Short of it's Fully Up or Down Posi-
tion".
3. Replace third row power folding seat motor LH. Refer to SE-57, "
Exploded View".
12
LH seat has traveled past normal fold up
position
13 LH seat actuation cycle has taken too
long and timed out 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Check third row power folding seat motor LH motor cir- cuits. Refer to SE-33, "
Only One Third Row Power Fold-
ing Seat Will Operate".
3. Replace third row power folding seat motor LH. Refer to SE-57, "
Exploded View".
14 Third row power folding seat control unit
NVRAM data for LH seat position has
been corrupted Replace third row power folding seat control unit. Refer to
SE-
60, "Power seat cross beam".
15 Power supply to thir
d row power folding
seat control unit has been interrupted
during LH seat fold up/down cycle 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Replace third row power folding seat control unit. Refer to SE-60, "
Power seat cross beam".
21 RH seat has traveled past normal fold
down position 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Check third row power folding seat motor RH Hall signal and ground circuits. Refer to SE-37, "
Third Row Power
Folding Seat Stops Short of it's Fully Up or Down Posi-
tion".
3. Replace third row power folding seat motor RH. Refer to SE-57, "
Exploded View".
22
RH seat has traveled past normal fold up
position
23 RH seat actuation cycle has taken too
long and timed out 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Check third row power folding seat motor RH motor cir- cuits. Refer to SE-33, "
Only One Third Row Power Fold-
ing Seat Will Operate".
3. Replace third row power folding seat motor RH. Refer to SE-57, "
Exploded View".
24 Third row power folding seat control unit
NVRAM data for RH seat position has
been corrupted Replace third row power folding seat control unit. Refer to
SE-
60, "Power seat cross beam".
25 Power supply to thir
d row power folding
seat control unit has been interrupted
during RH seat fold up/down cycle 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Replace third row power folding seat control unit. Refer
to SE-60, "
Power seat cross beam".
33 System normal or END of chime codes —
Revision: April 20092010 QX56
Page 3303 of 4210

THIRD ROW POWER FOLDING SEATSE-31
< SYMPTOM DIAGNOSIS >
C
DE
F
G H
I
K L
M A
B
SE
N
O P
SYMPTOM DIAGNOSIS
THIRD ROW POWER FOLDING SEAT
Symptom TableINFOID:0000000005147394
Symptom Reference
None of the third row power folding seats will operate with any switch. Refer to
SE-32, "
None of the Third Row Power Folding
Seats Will Operate With Any Third Row Power Folding
Seat Switch".
Only one third row power folding seat will operate. Refer to
SE-33, "
Only One Third Row Power Folding Seat
Will Operate".
Third row power folding seat will operate in only one direction. Refer to
SE-35, "
Third Row Power Folding Seat Will Oper-
ate in Only One Direction".
Third row power folding seat will stop short of its fully up or down position. Refer to
SE-37, "
Third Row Power Folding Seat Stops
Short of it's Fully Up or Down Position".
Third row power folding seat makes excessive noise while moving. Refer to
SE-38, "
Third Row Power Fold ing Seat Makes Ex-
cessive Noise While Moving".
Seats make squeak or rattle noise. Refer to SE-39, "
Work Flow".
Revision: April 20092010 QX56
Page 3304 of 4210

SE-32
< SYMPTOM DIAGNOSIS >
NONE OF THE THIRD ROW POWER FOLDING SEATS WILL OPERATE WITH
ANY SWITCH.
NONE OF THE THIRD ROW POWE R FOLDING SEATS WILL OPERATE
WITH ANY SWITCH.
None of the Third Row Power Folding Seat s Will Operate With Any Third Row Power
Folding Seat Switch
INFOID:0000000005147395
Regarding Wiring Diagram information, refer to SE-24, "Wiring Diagram".
1.PRELIMINARY CHECK
Perform preliminary check. Refer to SE-5, "
Preliminary Check".
Are inspection results normal?
YES >> GO TO 2.
NO >> Perform repairs as necessary.
2.THIRD ROW POWER FOLDING SEAT SWITCH GROUND
1. Turn ignition switch OFF.
2. Disconnect any third row power folding seat switch connector.
3. Check continuity between third row power folding seat switch harness connector terminal 4 and ground.
Is there continuity?
YES >> GO TO 3.
NO >> Repair ground circuit.
3.TRANSMISSION RANGE SWITCH SIGNAL
1. Confirm A/T selector lever is in PARK position.
2. Turn ignition switch ON.
3. Check voltage between third row power folding seat control unit harness connector B401 terminal 7 and ground.
Is there battery voltage?
YES >> Replace third row power folding seat control unit. Refer to SE-60, "Power seat cross beam".
NO >> Repair circuit as necessary.
ALJIA0116ZZ
Terminals Ignition switch
(+)
(-)ON
Third row power
folding seat
control unit Te r m i n a l N o .
B401 7Ground Battery voltage
ALJIA0278ZZ
Revision: April 20092010 QX56