Page 1065 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont'd)
• COOLING FANCIRCUIT.
DOES
COOLING FAN
ROTATE ANDSTOP
EVERY 3SECONDS
7
NEXT
II
NO
II
YES
I
MEF311F
• ACTIVE TEST.
0
COOLING FAN
OFF
= ==
MONITOR
==
=
COOLAN TEMP/S
HI
With airconditioner
C
k
00lin9fan
Q
~ID~
MEF277G
M/T
models
INSPECTION START
CHECK OVERALL FUNCTION.
(ij\
1.Turn ignition switch"ON".
~ 2.Perform "COOLING FAN
CIRCUIT" in"FUNCTION
TEST" modewithCONSULT.
OR
rij\
1.Turn ignition switch"ON".
\J!V
2.Select "COOLING FAN"in
"ACTIVE TEST"modewith
CONSULT.
OR
I
With airconditioner
I
1. Start engine.
2. Set temperature leveratfull cold
position.
3. Turn airconditioner switch"ON".
4. Turn blower fanswitch "ON".
5. Run engine atidle forafew minutes
with airconditioner operating.
6. Make surethatcooling fanoperates.
I
Without airconditioner
I
1. Start engine.
2. Keep engine speedatabout 2,000
rpm until engine iswarmed upsuffi-
ciently.
3. Make surethatcooling fanbegins to
operate duringwarm-up.
NG
CHECK POWER SUPPLY.
1. Turn airconditioner switch"OFF".
2. Turn blower fanswitch "OFF"
(Step 1and 2are only performed for
models withairconditi.oner.)
3. Stop engine.
4. Disconnect coolingfanrelay.
5. Turn ignition switch"ON".
6. Check voltage between terminals
G),
@
and ground.
Voltage: Batteryvoltage
OK
@
EC-346 OK
NG
INSPECTION
END
Check thefollowing.
• 30A fusible link
• 10A fuse
• Harness foropen or
short between fuseand
cooling fanrelay
• Harness foropen or
short between battery
and cooling fanrelay
If NG, repair harness or
connectors.
Page 1066 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont'd)
@
SEF777P
MEC775B
~io ~i5
1=1
=EC=M=W
CONNECTOR
II~
CHECK
GROUND CIRCUIT.
1. Turn ignition switch"OFF".
2. Disconnect coolingfanmotor-1 har-
ness connector andcooling fan
motor-2 harness connector.
3. Check harness continuity between
terminal
G)
and terminal
@,
termi-
nal
@
and body ground.
Continuity shouldexist.
(!] CHECK OUTPUT SIGNALCIRCUIT.
1. Disconnect ECMharness connector.
2. Check harness continuity between
ECM terminal
@
and terminal
@.
Continuity shouldexist.
If OK, check harness forshort.
OK
CHECK COMPONENT
(Cooling fanrelay).
Refer to"COMPONENT INSPECTION",
EC-353.
OK NG
NG
NG
Repair
harness orcon-
nectors.
Check thefollowing.
• Harness connectors
(]D,@
• Harness connectors
@,@D
• Harness foropen or
short between ECM
and cooling fanrelay
If NG, repair harness or
connectors.
Replace coolingfan
relay.
•
CHECK COMPONENTS
SEF332Q
(Coolingfanmotors).
Refer to"COMPONENT INSPECTION",
EC-353.
Disconnect andreconnect harnesscon-
nectors inthe circuit. Thenretest.
Trouble isnot fixed.
Check ECMpinterminals fordamage
and check theconnection ofECM har-
ness connector. ReconnectECMhar-
ness connector andretest.
INSPECTION END
EC-347 NG
Replace coolingfan
motors.
Page 1067 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont'd)
AlT models
INSPECTION START
Checkcooling fanlow
speed control circuit.
(Go to
I
PROCEDURE A
I,
EC-350.)
NG
2. Turn ignition switch"ON".
3. Perform "COOLING FAN
CIRCUIT" in"FUNCTION
TEST" modewithCONSULT.
OR
2. Turn ignition switch"ON".
3. Perform "COOLING FAN"in
"ACTIVE TEST"modewith
CONSULT. OR
CHECK
COOLING FANLOW SPEED
OPERATION. 1. Disconnect coolingfan
re/ays-2
and
-3.
00
COOLING FAN
ROTATE ANDSTOP
EVERY 3SECONDS
I
•
COOLING FANCIRCUIT.
DOES
OK
NEXT
II
NO
II
YES
JF311F
(j)
I
With airconditioner
I
2. Start engine.
3. Set temperature leveratfull cold
position.
4. Turn airconditioner switch"ON".
5. Turn blower fanswitch "ON".
6. Run engine atidle forafew minutes
with airconditioner operating.
7. Make surethatcooling fanoperates
at low speed.
I
Without airconditioner
1
2. Start engine.
3. Keep engine speedatabout 2,000
rpm until engine iswarmed upsuffi-
ciently.
4. Make surethatcooling fanbegins to
operate atlow speed during warm-
up.
COOLAN
TEMPjS 88°C
•
ACTIVE TEST.
0
COOLING FAN
OFF
= ==
MONITOR
===
With airconditioner
lCOOtingfan
@l
~ID~
==H=I
=11L~W I
EC-348
Page 1068 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont'd)
• COOLING FANCIRCUIT.
DOES
Cooling fan
MEC475B
COOLING
FAN
•
Check
cooling fanhigh
speed control circuit.
(Go to
I
PROCEDURE B
I.
EC-351.)
NG
OK
CHECK
COOLING FANHIGH SPEED
OPERATION.
1. Turn ignition switch"OFF".
2. Reconnect coolingfanrelays-2 and
-3.
3. Disconnect coolingfanrelay-1.
(ij\
4.Turn ignition switch"ON".
~ 5.Perform "COOLING FAN
CIRCUIT" in"FUNCTION
TEST" modewithCONSULT.
OR
fiii\
4.Turn ignition switch"ON".
~ 5.Perform "COOLING FAN"in
"ACTIVE TEST"modewith
CONSULT.
OR
4. Turn airconditioner switch
and blower fanswitch "OFF"
(Models withairconditioner).
5. Disconnect enginecoolant
temperature sensorharness
connector.
6. Connect 150Qresistor to
engine coolant temperature
sensor harness connector.
7. Restart engineandmake sure
that cooling fanoperates at
higher speedthanlowspeed.
Ii
--- ---
150(1 resistor
ROTATE
ANDSTOP
EVERY 3SECONDS
"I
NEXT
II
NO
II
YES
I
MEF311F
COOLAN TEMP/S
•
ACTIVE TEST. D
COOLING FAN
OFF
= ==
MONITOR
clTJI
LOW
1.1-
MEF314F
Ii
Ii
INSPECTIONEND
EC-349
Page 1069 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont'd)
PROCEDURE A
INSPECTION START
Checkthefollowing.
• 10A fuse
• 30A fusible link
• Harness foropen or
short between cooling
fan relay-1 andfuse
• Harness foropen or
short between cooling
fan relay-1 andbattery
If
NG, repair harness or
connectors.
Repair harness orcon-
nectors.
Replace coolingfanrelay.
Check
thefollowing.
• Harness connectors
@D,@
• Harness connectors
@,QD
• Harness foropen or
short between cooling
fan relay-1 andECM
If
NG, repair harness or
connectors.
NG
NG
NG
OK
OK
@
CHECK
GROUND CIRCUIT.
1. Turn ignition switch"OFF".
2. Disconnect coolingfanmotor-1 har-
ness connector andcooling fan
rnotor-2 harness connector.
3. Check harness continuity between
cooling fanrelay-1 terminal
@
and
cooling fanmotor-1 terminal
CD,
cool-
ing fan relay-1 terminal
(J)
and cool-
ing fan motor-2 terminal
CD.
Continuity shouldexist.
If OK, check harness forshort.
4. Check harness continuity between
terminal
@
and body ground.
Continuity shouldexist.
If
OK, check harness forshort.
CHECK COMPONENT
(Cooling fanrelay-1).
Refer to"COMPONENT INSPECTION",
EC-353.
/
0
CHECK OUTPUT SIGNALCIRCUIT.
1. Disconnect ECMharness connector.
2. Check harness continuity between
ECM terminal
@
and terminal
@.
Continuity shouldexist.
If
OK, check harness forshort.
~
I
CHECK POWER SUPPLY.
1. Turn ignition switch"OFF".
2. Disconnect coolingfanrelay-1.
3. Turn ignition switch"ON".
SEF725QB
4.Check voltage between terminals
CD,
@, @
and ground withCONSULT or
tester.
Voltage: Batteryvoltage
OK
~ SEF723QA
IJ;
3
7 5
2 1
Cooling fan
relay-1
~io~io~io
~3 .~
.-fT1
7 5 ~ ~
21.
C ,. Cooling Cooling
00
Ing
f
I1 fanmotor-1 fanmotor-2
an reay-
Cooling. fan
S S
Cooling fan
motor-1
\lliJ
~motor-2
SEF727QA EC-350
Page 1070 of 1701

Replacecoolingfan
motors.
CHECK
COMPONENT
(Cooling fanmotors-1 and-2).
Refer to"COMPONENT INSPECTION",
EC-353.
~
INNEer
Cooling
fan
relay-1
illi
3
7
5
2 1
TROUBLE
DIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont'd)
@
~
~15
ECM
~CONNECTORII
9
II
o
OK
Disconnect andreconnect harnesscon-
nectors inthe circuit. Thenretest.
Trouble isnot fixed.
Check ECMpinterminals fordamage
and check theconnection ofECM har-
ne&s connector. ReconnectECMhar-
ness connector andretest.
•
[ INSPECTION END
~i5
~-
clf:tb
Cooling fan
relay-2
~-
ffi:b
Cooling fan
relay-3
SEF781PPROCEDURE
B
INSPECTION START
CHECK POWER SUPPLY.
1. Turn ignition switch"OFF"
2. Disconnect coolingfanrelays-2 and
-3.
3. Turn ignition switch"ON".
4. Check voltage between coolingfan
relay-2 terminals
CD,
@and ground,
and between coolingfanrelay-3 ter-
minals
CD,
@and ground withCON-
SUL Tor tester.
Voltage: Batteryvoltage
OK
@
NG
Check thefollowing.
• 10A fuse
• 30A fusible link
• Harness foropen or
short between cooling
fan relays-2, -3and fuse
• Harness foropen or
short between cooling
fan relays-2, -3and bat-
tery
If
NG, repair harness or
connectors.
EC-351
Page 1071 of 1701

Repairharness orcon-
nectors.
NG
CHECK GROUND CIRCUIT.
1. Turn ignition switch"OFF".
2. Disconnect coolingfanmotor-1 har-
ness connector andcooling fan
motor-2 harness connector.
Ia
3.Check harness continuity between
terminal
@
and terminal
@,
ter-
minal
@
and terminal
@,
termi-
nal
CV
and body ground.
Continuity shouldexist.
If OK, check harness forshort.
II
4.Check harness continuity between
terminal
@
and terminal
@,
ter-
minal
@
and terminal
@,
termi-
nal
CV
and body ground.
Continuity shouldexist.
If OK, check harness forshort.
1f,
2
3 4
Cooling fan
motor-1
harness
connector
TROUBLE
DIAGNOSIS FORNON';DETECTABLE ITEMS
Cooling FanControl (Cont'd)
@
1
~ ii
O
Cooling
6
3
fan
7 5
relay-2
2 1
II
~ iifO
Cooling
6
3
fan
7 5 relay-3
2 1 SEF782PA
tllii
It
Cooling fan
motor-2
harness
connector
111
CHECK OUTPUT SIGNALCIRCUIT.
1. Disconnect ECMharness connector.
2. Check harness continuity between
ECM terminal
@J
and terminal
@.
Continuity shouldexist.
If OK, check harness forshort.
OK
CHECK COMPONENT
(Cooling fanrelays-2, 3).
Refer to"COMPONENT INSPECTION"
on next page.
NG
NG
Check
thefollowing.
• Harness connectors
CID.@
• Harness connectors
@,@
• Harness foropen or
short between cooling
fan relays-2. 3and ECM
If NG. repair harness or
connectors.
Replace coolingfan
relays.
OK
CHECK COMPONENTS
(Cooling fanmotors).
Refer to"COMPONENT INSPECTION"
on next page. Replace
coolingfan
motors.
OK
Disconnect andreconnect harnesscon-
SEF783PA
nectarsinthe circuit. Thenretest.
II
~15
~Io
f,:j!
I
Cooling
ECM
ElCONNECTORI
fan
10
relay-2,-3
~
[?Ffu
Trouble
isnot fixed.
Check ECMpinterminals fordamage
and check theconnection ofECM har-
ness connector. ReconnectECMhar-
ness connector andretest.
INSPECTION END
MEC7788 EC-352
Page 1072 of 1701
SEF511PA
•
No
Yes
Continuity
Conditions
12V direct current supplybetween
terminals
CD
and
@
No current supply
If NG, replace relay.
=
TROUBLE
DIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont'd)
COMPONENT INSPECTION
Cooling fanrelay (M/Tmodels)
Check continuity betweenterminals
@
and
CID.
MIT
models
Coolingfanrelays-1, -2and -3(A/T models)
Check continuity betweenterminals
@
and
CID,
@and
(j).
AlT
models
Conditions
12V direct current supplybetween
terminals
CD
and
@
No current supply
If NG, replace relay.
Continuity
YesNo
SEC202BA
Terminals
Speed
(Ee)
(8)
Low
CD
@
(A/T
models)
Cooling fan High
CD,@
@,@
motor
(A/T
models)
High
CD@
(M/T models)
Cooling fanmotor should operate.
If NG, replace coolingfanmotor.
Cooling
fanmotors-1 and-2
1. Disconnect coolingfanmotor harness connectors.
2. Supply cooling fanmotor terminals withbattery voltage and
check operation.
AEC715
Cooling
fanmotor
harness connector
For MIT models
For
AIT Models
AEC,81EC-353