Connector melted, not
affecting performance .. 2 ........... (1) Suggest repair or
replacement.
Connector missing ....... C ............ Require replacement.
Hydraulic fan motor
leaking ................ A .. Require repair or replacement.
Inoperative ............. A ........ ( 2) Require replacement.
Missing ................. C ............ Require replacement.
Noisy ................... 2 ............ Suggest replacement.
Rotation incorrect for
application ............ B .. Require repair or replacement.
Terminal broken ......... A .. Require repair or replacement.
Terminal burned, affecting
performance ............ A ........... ( 1) Require repair or
replacement.
Terminal burned, not
affecting performance .. 2 .. Suggest repair or replacement.
Terminal corroded,
affecting performance .. A .. Require repair or replacement.
Terminal corroded, not
affecting performance .. 2 .. Suggest repair or replacement.
Terminal loose, affecting
performance ............ B .. Require repair or replacement.
Terminal loose, not
affecting performance .. 1 .. Suggest repair or replacement.
Vibration ............... 1 ............ Suggest replacement.
Wire lead conductors
exposed ................ B .. Require repair or replacement.
Wire lead corroded ...... A .. Require repair or replacement.
Wire lead open .......... A .. Require repair or replacement.
Wire lead shorted ....... A .. Require repair or replacement.
( 1) - Determine cause and correct prior to repair or
replacement of part.
( 2) - Check fan motor/controls. Inoperative includes
intermittent operation or out of OEM specification.
\
\
\
\
\
\
\
EVAPORATOR DRAIN TUBES
EVAPORATOR DRAIN TUBE INSPECTION \
\
\
\
\
\
\
Condition Code Procedure
Disconnected ............ A ................. Require repair.
Leaking ................. A ............ Require replacement.
Missing ................. C ............ Require replacement.
Restricted .............. A .. Require repair or replacement.
Routed incorrectly ...... B ................. Require repair.
\
\
\
\
\
\
\
EVAPORATOR PRESSURE REGULATORS (EPRS)
EVAPORATOR PRESSURE REGULATOR (EPR) INSPECTION \
\
\
\
\
\
\
Condition Code Procedure
Inoperative ............. A ........... ( 1) Require repair or
replacement.
( 1) - Inoperative includes intermittent operation or out of
OEM specification.
\
\
\
\
\
\
\