1998 MITSUBISHI MONTERO Service Manual

Page 833 of 1501

MITSUBISHI MONTERO 1998  Service Manual Fig. 15:  Identifying Instrument Panel Fuel Gauge Resistance Check
Terminals (Montero Sport)
Courtesy of Mitsubishi Motor Sales of America
Fig. 16:  Identifying Instrument Panel Fuel Gauge Resistance

Page 834 of 1501

MITSUBISHI MONTERO 1998  Service Manual          Eclipse 2.0L Non-Turbo With A/T
         Disconnect sensor harness connector. Check resistance between
sensor terminals. Resistance should be 300-1200 ohms. Replace sensor
as necessary.

Page 835 of 1501

MITSUBISHI MONTERO 1998  Service Manual Fig. 18:  Oil Pressure Gauge Resistance Test Terminals (Montero)
Courtesy of Mitsubishi Motor Sales of America
Fig. 19:  Oil Pressure Gauge Resistance Test Terminals (3000GT)
Courtesy of Mitsubishi Mo

Page 836 of 1501

MITSUBISHI MONTERO 1998  Service Manual unit. Turn ignition on. Check voltage between ground and sending unit
harness-side connector. If battery voltage is present, problem is
intermittent. If battery voltage is not present, go to next step

Page 837 of 1501

MITSUBISHI MONTERO 1998  Service Manual          Calibration Test
         Adjust tire pressure to standard value. Using a calibrated,
reliable speedometer tester, compare reading of vehicle speedometer to
speedometer tester. See SPEEDOMETE

Page 838 of 1501

MITSUBISHI MONTERO 1998  Service Manual present, go to next step.
         5) Check harness connectors to vehicle speed sensor and
ignition switch. See WIRING DIAGRAMS. Repair as necessary. If
connectors are okay, check circuit between vehi

Page 839 of 1501

MITSUBISHI MONTERO 1998  Service Manual voltage between ground and harness-side connector terminal No. 33
(White wire). See WIRING DIAGRAMS. Voltmeter should read 5 volts. If
voltage is as specified, replace tachometer. If voltage is not as

Page 840 of 1501

MITSUBISHI MONTERO 1998  Service Manual speedometer.
         TEMPERATURE GAUGE
CAUTION:  DO NOT connect sender wire directly to ground during test.
          Circuit Test
         1) Disconnect temperature sender wire from sending unit.
Co