2004 DAEWOO LACETTI Service Repair Manual

Page 1433 of 2643

DAEWOO LACETTI 2004  Service Repair Manual 5A1 – 84IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DTC P0703 – Brake Switch Circuit Malfunction
StepActionValue(s)YesNo
1Perform an On–Board Diagnostic (EOBD) System
Check.
Is the check

Page 1434 of 2643

DAEWOO LACETTI 2004  Service Repair Manual ZF 4 HP 16 AUTOMATIC TRANSAXLE  5A1 – 85
DAEWOO V–121 BL4
StepNo Yes Value(s) Action
13Repair the short to power between the brake switch
wiring connector and TCM.
Is the action complete?–System

Page 1435 of 2643

DAEWOO LACETTI 2004  Service Repair Manual 5A1 – 86IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P0705
TRANSMISSION RANGE SENSOR CIRCUIT
MALFUNCTION (PRNDL INPUT)
Circuit Description
The Transmission range s

Page 1436 of 2643

DAEWOO LACETTI 2004  Service Repair Manual ZF 4 HP 16 AUTOMATIC TRANSAXLE  5A1 – 87
DAEWOO V–121 BL4
Gear Position And Range Signal Chart.
L1L2L3L4
P00120
R00012
N01200
D1212120
31212012
21201212
10121212
DTC P0705 – Transmission Range S

Page 1437 of 2643

DAEWOO LACETTI 2004  Service Repair Manual 5A1 – 88IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
StepNo Yes Value(s) Action
8Repair the malfunctioning terminals as necessary.
Is the action complete?–System OK–
91.  Turn the ignition

Page 1438 of 2643

DAEWOO LACETTI 2004  Service Repair Manual ZF 4 HP 16 AUTOMATIC TRANSAXLE  5A1 – 89
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P0710
TRANSMISSION FLUID TEMPERATURE SENSOR
CIRCUIT MALFUNCTION
Circuit Description
The TFT sensor is a posit

Page 1439 of 2643

DAEWOO LACETTI 2004  Service Repair Manual 5A1 – 90IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DTC P0710 – Transmission Fluid Temperature Sensor Circuit
Malfunction
StepActionValue(s)YesNo
1Perform an On–Board Diagnostic (EOBD) Sy

Page 1440 of 2643

DAEWOO LACETTI 2004  Service Repair Manual ZF 4 HP 16 AUTOMATIC TRANSAXLE  5A1 – 91
DAEWOO V–121 BL4
StepNo Yes Value(s) Action
91.  Turn the ignition ON.
2.  Measure the voltage of terminal A4 of the TCM
wiring connector.
3.  Measure the