1992 MAZDA PROTEGE Workshop Manual

Page 417 of 1164

MAZDA PROTEGE 1992  Workshop Manual CONTROL SYSTEM F 
VB: Battery voltage 
incorrect voltage POBSible cause 
Alwvs OV’ l ROOM IOA fuse burned l Open circuit in wiring from ROOM IOA fuse to ECU terminal 1A 
Always OV 
l Main relay malf

Page 418 of 1164

MAZDA PROTEGE 1992  Workshop Manual F CONTROL SYSTEM 
VB: Battery voltage 
erminal Input Output Connection to Test condition Corrsct voltage Remark 
1M - - - - - - 
IN 0 Throttle sensor Accelerator pedal released ov Ignition switch 
(Id

Page 419 of 1164

MAZDA PROTEGE 1992  Workshop Manual CONTROL SYSTEM F 
Ve: Battery voltage 
Incorrect voltage 
1, - 
Always below l.OV 
Always Ve 
Always below I.OV (Stoplight OK) 
Always below l.OV 
Always 
VB 
Always below 25V (Blower fan OK) 
Always

Page 420 of 1164

MAZDA PROTEGE 1992  Workshop Manual CONTROL SYSTEM 
Ve: Battery 
arminal Input Output Connection to lest condition Correct voltage Remark 
2A - - Ground (Injector) Constant ov - 
28 - - Ground (Output) Constant ov - 
2c - - Ground (CPU)

Page 421 of 1164

MAZDA PROTEGE 1992  Workshop Manual CONTROL SYSTEM 
Ve: Battery voltage 
Incorrect voltage 
I Possible cause 
4bove OV 
l Poor contact at ground terminal l Open circuit in wiring from ECU to ground 
Always approx. OV or approx. 2V 
l Re

Page 422 of 1164

MAZDA PROTEGE 1992  Workshop Manual F CONTROL SYSTEM 
Ve: Battery voltage 
erminal Input Output Connection to 
Test condition Correct voltage Remark 
2s 0 Solenoid valve 
Engine speed below 5,000 rpm ov VICS: Variable In- 
(VICS) 
Engin

Page 423 of 1164

MAZDA PROTEGE 1992  Workshop Manual CONTROL SYSTEM 
Incorrect voltage 
Always OV or VB 
Always OV or VS 
VB: BBttWy voltage 
Possible cause 
l Refer to Code No.41 Troubleshooting (Refer to page F-103) 
l Refer to Code No.25 Troubleshoot

Page 424 of 1164

MAZDA PROTEGE 1992  Workshop Manual F CONTROL SYSTEM 
Terminal voltage (ATX) 
VB: Battery voltage 
erminal Input Output 
Connection to Test condition Correct voltage Remark 
IA - - 
Battery Constant --- Va For backup 
16 0 Main relay 
l