1996 TOYOTA TERCEL Service Repair Manual

Page 681 of 1202

TOYOTA TERCEL 1996  Service Repair Manual P13734
Terminal F CH-4
- CHARGINGCHARGING SYSTEM
1996 TERCEL   (RM440U)
Connect  the positive (+) tester probe of the amme-
ter to terminal B of the generator.
Connect  the positive (+) tester probe

Page 682 of 1202

TOYOTA TERCEL 1996  Service Repair Manual CH0H8-01
- CHARGINGGENERATOR
CH-5
681 Author: Date:
1996 TERCEL   (RM440U)
GENERATOR
COMPONENTS

Page 683 of 1202

TOYOTA TERCEL 1996  Service Repair Manual CH0H9-01
P13685
P21508
Adjusting Bolt
Pivot Bolt
CH-6
- CHARGINGGENERATOR
1996 TERCEL   (RM440U)
REMOVAL
1. DISCONNECT CONNECTOR AND WIRE FROM
GENERATOR
(a) Disconnect the connector from the generator

Page 684 of 1202

TOYOTA TERCEL 1996  Service Repair Manual P13686
CH0HA-01
Z10245
Type A
Z14809
Type B
P13644
P13688
- CHARGINGGENERATOR
CH-7
1996 TERCEL   (RM440U)
DISASSEMBLY
1. REMOVE REAR END COVER
(a) Remove the nut and terminal insulator.
(b) Type A:
Re

Page 685 of 1202

TOYOTA TERCEL 1996  Service Repair Manual Z19162
Type A
Z14812
Type B
P04209
SST(A)
Turn SST(B)
P04210
SST (C)
CH-8
- CHARGINGGENERATOR
1996 TERCEL   (RM440U)
3. Type A
REMOVE RECTIFIER HOLDER
(a) Remove the 4 screws and rectifier holder.
(b)

Page 686 of 1202

TOYOTA TERCEL 1996  Service Repair Manual P04394
SST (C)
SST (A)
Turn
P04393
SST (A)
SST (B)
Turn
Z19163
Type A
Z14814
Type B
P13692
SST
- CHARGINGGENERATOR
CH-9
1996 TERCEL   (RM440U)
(e) To loosen the pulley nut, turn SST (A) in the directi

Page 687 of 1202

TOYOTA TERCEL 1996  Service Repair Manual CH-10
- CHARGINGGENERATOR
1996 TERCEL   (RM440U)
(d) Using snap ring pliers, remove the generator washer from
the rectifier end frame.
7. REMOVE ROTOR FROM DRIVE END FRAME

Page 688 of 1202

TOYOTA TERCEL 1996  Service Repair Manual CH0HB-01
CH0784
Ohmmeter
Continuity
CH0783
Ohmmeter
No Continuity
CH1023
P04189
Ohmmeter
Continuity
P04215
Ohmmeter No Continuity
- CHARGINGGENERATOR
CH-1 1
1996 TERCEL   (RM440U)
INSPECTION
1. INSPEC