2013 SSANGYONG TURISMO Service Manual

Page 321 of 796

SSANGYONG TURISMO 2013  Service Manual 14-92412-02
Differential Pressure Sensor
Calculates the amount of PM 
collected by reading the pressure 
difference between pre-CDPF and 
post-CDPF.Engine ECU (D20DTR)
Post injection
Electric Throttle

Page 322 of 796

SSANGYONG TURISMO 2013  Service Manual 14-10
3. INPUT/OUTPUT DEVICES
Front temperature sensor: This sensor is installed at the inlet of DOC and detects whether the 
DOC can burn (oxidize) the post-injected fuel or not.
Rear temperature sen

Page 323 of 796

SSANGYONG TURISMO 2013  Service Manual 14-112412-02
4. POST-INJECTION AND AIR MASS CONTROL
A DPS (Differential Pressure Sensor) measures the pressure difference between before and after the 
CDPF and detects whether the soot is collected i

Page 324 of 796

SSANGYONG TURISMO 2013  Service Manual 14-12
Rear temperature sensor
Measure the outlet 
temperature of DOC.
This sensor is located at the 
rear side of DOC and 
monitors the overheating of 
CDPF and post injection 
volume.
Differential pr

Page 325 of 796

SSANGYONG TURISMO 2013  Service Manual 14-132412-02
Collecting PM
→ Regeneration
The engine ECU detects the 
amount of PM collected by the 
information from the 
temperature sensors and 
differential pressure sensor. 
When the soot is ac

Page 326 of 796

SSANGYONG TURISMO 2013  Service Manual 14-14
1) Oxidation of DOC
The DOC oxidizes HC and CO of the exhaust gas in the two-way catalytic converter at 180℃ or 
more, and performs best at the temperature between 400 and 500℃. The front EG

Page 327 of 796

SSANGYONG TURISMO 2013  Service Manual 14-152412-02
2) Collecting PM of DPF
There is a filter installed in the DPF and the PM filtered by this filter is burned (regeneration) when the 
temperature of exhaust gas is increased due to post-in

Page 328 of 796

SSANGYONG TURISMO 2013  Service Manual 14-16
3) PM Regeneration of DPF
The differential pressure sensor installed in the DPF measures the pressure values of inlet and outlet of 
CDPF. And the amount of the PM collected in the filter is cal