1998 HONDA INTEGRA Workshop Manual

Page 825 of 1681

HONDA INTEGRA 1998 4.G Workshop Manual Doors
Glass/Regulator/Glass Run Channel Replacement
Remove:
a Door panel (see page 2O-4)
a Plastic cover (see page 20 4)
Remove the power window switch Jrom the door
panel, then connect it to the door

Page 826 of 1681

HONDA INTEGRA 1998 4.G Workshop Manual )7.Carefully pull the glass out through the window slot.
NOTE:
a Take care not to drop the glass inside the door.
a Check the guide pin for damage, and replace it
it necessary.
NOTEr Scribe a line aro

Page 827 of 1681

HONDA INTEGRA 1998 4.G Workshop Manual Doors
Glass/Regulator/Glass Run Channel Replacement (contd)
9. Remove the power window motor from the
regulator.
NOTE: Before removing the power window motor,
mark the location by scribing a line acr

Page 828 of 1681

HONDA INTEGRA 1998 4.G Workshop Manual 12. Apply clear sealant to locations @ on the door as
shown, then install the glass run channel.
NOTEI
a lf necessary, replace any damaged clips
>: Clip locarion, 3
Fit the glass run channel into the

Page 829 of 1681

HONDA INTEGRA 1998 4.G Workshop Manual Doors
Front and Center ChannelReplacement
NOTE: Raise the glass tully.
L Remove:
a Door panel (see page 2O-4)
a Plastic cover (see page 2O-4)
2. Remove the front and center channels.
<: Bolt locations

Page 830 of 1681

HONDA INTEGRA 1998 4.G Workshop Manual Outer Molding Replacement
CAUTION: Wear gloves to remove the outer molding.
1. Remove the power mirror (see page 20-49).
2. Lower the glass.
3. Starting at the rear, pry the outer molding up and
detac

Page 831 of 1681

HONDA INTEGRA 1998 4.G Workshop Manual r
Doors
Glass Adjustment
< : Screw locations, 5
"od} l-,/
NOTE:
a Place the vehicle on a firm, level surface when adjust-
ing the glass.
a Check the weatherstrips and glass run channel for
damage or d

Page 832 of 1681

HONDA INTEGRA 1998 4.G Workshop Manual to.
11.
Raise the glass fully and check Ior gaps.
Check the glass operation.
NOTEi Check that the glass contacts the glass run
channel evenly.
12. Check for water leaks.
NOTE: Do not use high-pressur