2013 SSANGYONG NEW ACTYON SPORTS Service Manual

Page 217 of 751

SSANGYONG NEW ACTYON SPORTS 2013  Service Manual 15-170000-00
A fourth correction is made according to the pressure error.
This correction is used to reduce the injection timing advance when the pressure in the rail is higher 
than the pressure dema

Page 218 of 751

SSANGYONG NEW ACTYON SPORTS 2013  Service Manual 15-18
B. Driver Demand
The driver demand is the translation of the pedal position into the fuel demand. It is calculated as a 
function of the pedal position and of the engine speed. The driver demand

Page 219 of 751

SSANGYONG NEW ACTYON SPORTS 2013  Service Manual 15-190000-00
C. Idle Speed Controller
The idle speed controller consists of 2 principal modules:
The first module determines the required idle speed according to:
* The operating conditions of the eng

Page 220 of 751

SSANGYONG NEW ACTYON SPORTS 2013  Service Manual 15-20
F. Pilot Flow Control
The pilot flow represents the amount of fuel injected into the cylinder during the pilot injection. This 
amount is determined according to the engine speed and the total f

Page 221 of 751

SSANGYONG NEW ACTYON SPORTS 2013  Service Manual 15-210000-00
MDP (Minimum Drive Pulse ) refers to the 
minimum power supply pulse for injection which 
the injector can perform. It is possible to control 
the fuel volume for each injector accurately

Page 222 of 751

SSANGYONG NEW ACTYON SPORTS 2013  Service Manual 15-22
C. Learning Conditions
Idle MDP learning Drive MDP learning
Coolant temperatureover 60℃  over 60℃ 
Vehicle speedIdling over 50km/h (over 5 seconds)
Engine rpm2,000 to 2,500 rpm 
Fuel tempera

Page 223 of 751

SSANGYONG NEW ACTYON SPORTS 2013  Service Manual 15-230000-00
(7) Knocking Control
A. Resetting the pilot injection
The knocking control is used to reset the pilot injection flow in closed loop for each injector. This method 
allows the correction o

Page 224 of 751

SSANGYONG NEW ACTYON SPORTS 2013  Service Manual 15-24
This is done periodically under certain operating conditions. When the resetting is finished, the new 
minimum pulse value replaces the value obtained during the previous resetting. The first MD