Page 65 of 260
REMOTE KEYLESS ENTRY SYSTEM
BL-65
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2006 November2007 350Z
Wiring Diagram — KEYLES — /For Coupe NIS00019
TIWT2263E
Page 66 of 260
BL-66
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 November2007 350Z
TIWT1577E
Page 67 of 260
REMOTE KEYLESS ENTRY SYSTEM
BL-67
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2006 November2007 350Z
TIWT2264E
Page 68 of 260
BL-68
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 November2007 350Z
Wiring Diagram — KEYLES — /For Roadster NIS0001A
TIWT2265E
Page 69 of 260
REMOTE KEYLESS ENTRY SYSTEM
BL-69
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2006 November2007 350Z
TIWT1580E
Page 70 of 260
BL-70
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 November2007 350Z
TIWT2266E
Page 71 of 260

REMOTE KEYLESS ENTRY SYSTEM
BL-71
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2006 November2007 350Z
Terminals and Reference Value for BCMNIS0001B
*1: When interior lamp battery saver control is in OFF: Approx 5V.
*2: For roadster.Te r -
minal Wire
colorItemSignal
input/
outputConditionVoltage (V)
(Approx.)
11 LG Ignition switch (ACC) Input Ignition switch (ACC or ON position) Battery voltage
12 P Passenger side door switch Input ON (Open) → OFF (Closed) 0 → 5
18 BRemote keyless entry
receiver (Ground)—— 0
19 YRemote keyless entry
receiver (Power supply)OutputKey is inserted in IGN key cylinder 0
All door closed
20 LRemote keyless entry
receiver (Signal)InputKey is inserted in IGN key cylinder 0
Waiting
(All door closed)
When signal is received
(All door closed)
37 B/R Key switch (Insert) InputON (Key inserted) → OFF (Key
removed from IGN key cylinder)Battery voltage → 0
38 W/L Ignition switch (ON) Input Ignition switch (ON or START position) Battery voltage
39 L CAN – HInput/
Output——
40 P CAN – LInput/
Output——
42 GY Power source (Fuse) Input — Battery voltage
52 B Ground — — 0
55 R Power source (Fusible link) Input — Battery voltage
57 R/WTrunk lid lock assembly
(trunk room lamp switch)*
2Input
ON (Open) → OFF (Closed)
0 → Battery voltage*1
58 R/W Back door switch Input
62 L Driver side door switch Input ON (Open) → OFF (Closed) 0 → 5
OCC3881D
OCC3879D
OCC3880D
Page 72 of 260
BL-72
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 November2007 350Z
Terminals and Reference Value for IPDM E/RNIS0001C
*: In the state that horn reminder operates.
CONSULT-III Function (BCM)NIS0001D
CONSULT-III can display each diagnostic item using the diagnostic test modes shown following.
*:Refer to BCS-16, "CAN Communication Inspection Using CONSULT-III (Self-Diagnosis)" . Te r m i -
nal Wire
colorItemSignal
input/out-
putConditionVoltage (V)
(Approx.)
38 B Ground — — 0
48 L CAN – HInput/
Output—0
49 P CAN – LInput/
Output—0
51 G/B Horn relay InputWhen door lock is operated using
key fob*
(ON → OFF)Battery voltage → 0
60 B Ground — — 0
BCM diagnosis
positionInspection items and diagnosis mode Description
MULTI REMOTE
ENTData monitorDisplays the input remote keyless entry system data to
BCM on real–time basis.
Active test Sends a drive signal to check the operation.
Work support Changes the setting for each function.