Page 129 of 406

Page 19 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.4.11.1 Exceptions to separation between external circuits
and earth N/A
5.4.11.2 Requirements N/A
SPDs bridge separation between external circuit
and earth N/A
Rated operating voltage U
op (V) ............................. :
Nominal voltage U
peak (V) ................................ ....... :
Max increase due to variation U
sp ........................ :
Max increase due to ageing U
sa ......................... :
5.4.11.3 Test method and compliance ................................ : N/A
5.4.12 Insulating liquid N/A
5.4.12.1 Gener al requirements N/A
5.4.12.2 Electric strength of an insulating liquid .................. : N/A
5.4.12.3 Compatibility of an insulating liquid ....................... : N/A
5.4.12.4 Container for insulating liquid ................................ : N/A
5.5 Components as safeguards
N/A
5.5.1 General N/A
5.5.2 Capacitors and RC units No such component N/A
5.5.2.1 General requirement N/A
5.5.2.2 Safeguards against capacitor discharge after
disconnection of a connector ................................ . : N/A
5.5.3 Transformers No transformers N/A
5.5.4 Optocouplers No o ptocouplers N/A
5.5.5 Relays No Relays N/A
5.5.6 Resistors No Resistors N/A
5.5.7 SPDs No SPDs N/A
5.5.8 Insulation between the mains and an external
circuit consisting of a coaxial cable ....................... : N/A
5.5.9 Safeguards for socket - outlets in outdoor equipment N/A
RCD rated residual operat ing current (mA) ........... :
5.6 Protective conductor
N/A
5.6.2 Requirement for protective conductors N/A
5.6 Protective conductor
N/A
5.6.2 Requirement for protective conductors N/A
Page 130 of 406

Page 20 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.6.2.1 General requirements N/A
5.6.2.2 Colour of insulation N/A
5.6 .3 Requirement for protective earthing conductors N/A
Protective earthing conductor size (mm 2
) .............. :
Protective earthing conductor serving as a
reinforced safeguard N/A
Protective earthing conductor serving as a double
safeguard N/A
5.6.4 Require ments for protective bonding conductors N/A
5.6.4.1 Protective bonding conductors N/A
Protective bonding conductor size (mm 2
). .............. :
5.6.4.2 Protective current rating (A) ................................ .... : N/A
5.6.5 Terminals for protective conductors N/A
5.6.5.1 Terminal size fo r connecting protective earthing
conductors (mm) ................................ .................... : N/A
Terminal size for connecting protective bonding
conductors (mm) ................................ ....................... : N/A
5.6.5.2 Corrosion N/A
5.6.6 Resistance of the protective bonding system N/A
5.6.6.1 Requirements N/A
5.6.6.2 Test Method ................................ ........................... : N/A
5.6.6.3
R esistance ( ) or voltage drop .............................. : N/A
5.6.7 Reliable connection of a protective earthing
conductor N/A
5.6.8 Functional earthing N/A
Conductor size (mm 2
) ................................ ............. : N/A
Class II with functional earthing marking .............. : N/A
Appliance inlet cl & cr (mm) ................................ ... : N/A
5.7 Prospective touch voltage, touch current and protective conductor current
N/A
5.7.2 Measuring devices and networks N/A
5.7.2.1 Measurement of touch current N/A
5.7.2.2 Measurement of voltage N/A
5.7.3 Equipment set - up, supply c onnections and earth
connections N/A
5.7.4 Unearthed accessible parts ................................ ... : N/A
Page 131 of 406

Page 21 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.7.5 Earthed accessible conductive parts ..................... : N/A
5.7.6 Requirements when touch current exceeds ES2
limits N/A
Protective conductor current (mA) ......................... : N/A
Instructional Safeg uard ................................ .......... : N/A
5.7.7 Prospective touch voltage and touch current
associated with external circuits N/A
5.7.7.1 Touch current from coaxial cables N/A
5.7.7.2 Prospective touch voltage and touch current
associated with paired conductor cables N/A
5.7.8 S ummation of touch currents from external circuits N/A
a) Equipment connected to earthed external
circuits, current (mA) ................................ ............. : N/A
b) Equipment connected to unearthed external
circuits, current (mA) ................................ ............. : N/A
5.8 Backfeed safeguard in battery backed up supp lies
N/ A
Mains terminal ES ................................ ..................... : No battery backed up supplies N/ A
Air gap (mm) ................................ .............................. : N/ A
6 ELECTRICALLY - CAUSED FIRE
P
6.2 Classification of PS and PIS
P
6.2.2 Power source circuit classifications .......................... : (See appended table 6.2.2) P
6.2.3 Classification of potential ignition sources P
6.2.3.1 Arcing PIS ................................ ................................ : Open circuit voltage does not
exceed 50 V N/A
6.2.3.2 Resistive PIS ................................ ............................ : (See appended table 6.2.3.2) P
6.3 Safeguards against fire under normal operating and abnormal operating
conditions P
6.3.1 No ig nition and attainable temperature value less
than 90 % defined by ISO 871 or less than 300 C
for unknown materials ................................ ........... : No ignition and no such
temperature attained within
the equipment P
Combustible materials outside fire enclosure .......... : Min. HB P
6.4 Safeg uards against fire under single fault conditions
P
6.4.1 Safeguard method Control fire spread P
6.4.2 Reduction of the likelihood of ignition under single
fault conditions in PS1 circuits N/A
Page 132 of 406

Page 22 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
6.4.3 Reduction of the likelihood of ignition under single
f ault conditions in PS2 and PS3 circuits N/A
6.4.3.1 Supplementary safeguards N/A
6.4.3.2 Single Fault Conditions ................................ .......... : N/A
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits P
6.4.5 Control of fire s pread in PS2 circuits P
6.4.5.2 Supplementary safeguards For conductor and devices are
mounted on printed board
made of Min. V - 1.
Other components in PS2 are
mounted on printed board
made of Min. V - 1 and PVC
wire used .
Not ignite during single fault
cond ition . P
6.4.6 Control of fire spread in PS3 circuits Provided Metallic enclosure P
6.4.7 Separation of combustible materials from a PIS P
6.4.7.2 Separation by distance N/A
6.4.7.3 Separation by a fire barrier P
6.4.8 Fire enclosures and fire bar riers P
6.4.8.2 Fire enclosure and fire barrier material properties P
6.4.8.2.1 Requirements for a fire barrier V - 0 class material or metal,
Printed board made of V - 0 P
6.4.8.2.2 Requirements for a fire enclosure Metallic enclosure provi ded P
6.4.8.3 Constructional requirements for a fire enclosure
and a fire barrier P
6.4.8.3.1 Fire enclosure and fire barrier openings P
6.4.8.3.2 Fire barrier dimensions P
6.4.8.3.3 Top openings and properties E quipment for building - in ,
e valuation shall be considered
in the end product N/A
Openings dimensions (mm) ................................ ... : N/A
6.4.8.3.4 Bottom openings and properties E quipment for building - in ,
e valuation shall be considered
in the end product N/A
Openings dimensions (mm) ................................ ... : N/A
Flammability tests f or the bottom of a fire enclosure N/A
Page 133 of 406

Page 23 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
Instructional Safeguard ................................ ............. : N/A
6.4.8.3.5 Side openings and properties E quipment for building - in ,
e valuation shall be considered
in the end product N/A
Openings dimensions (mm) ................................ ... : N/A
6.4.8.3.6 Integrity of a fir e enclosure, condition met: a), b) or
c) ................................ ................................ ............ : Not such fire enclosure N/A
6.4.8.4 Separation of a PIS from a fire enclosure and a fire
barrier distance (mm) or flammability rating .......... : Not such fire enclosure P
6.4.9 Flammability of insulating liquid ............................... : N/A
6.5 Internal and external wiring
P
6.5.1 General requirements P
6.5.2 Requirements for interconnection to building wiring
................................ ................................ ............... : No such interconnection to
building wiring N/A
6.5.3 Internal wiring size (mm 2
) for socket - outlets .......... : N/A
6.6 Safeguards agai nst fire due to the connection to additional equipment
P
7 INJURY CAUSED BY HAZARDOUS SUBSTANCES
N/A
7.2 Reduction of exposure to hazardous substances
N/A
7.3 Ozone exposure
N/A
7.4 Use of personal safeguards or personal protective equipment (PPE)
N /A
Personal safeguards and instructions ................... :
7.5 Use of instructional safeguards and instructions
N/A
Instructional safeguard (ISO 7010) ........................ :
7.6 Batteries and their protection circuits
N/A
8 MECHANICALLY - CAUSED INJURY
P
8.2 Mechanical energy sou rce classifications
P
8.3 Safeguards against mechanical energy sources
P
8.4 Safeguards against parts with sharp edges and corners
P
8.4.1 Safeguards All edges and corners are
rounded or smoothed P
Instructional Safeguard ................................ ............. : MS1 N/A
8.4.2 Sharp edges or corners P
8.5 Safeguards against moving parts
N/A
Page 134 of 406

Page 24 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
8.5.1 Fingers, jewellery, clothing, hair, etc., contact with
MS2 or MS3 parts N/A
MS2 or MS3 part required to be accessible for the
function of the equipment N/A
Moving MS3 parts only accessi ble to skilled person N/A
8.5.2 Instructional safeguard ................................ .............. : N/A
8.5.4 Special categories of equipment containing moving
parts N/A
8.5.4.1 General N/A
8.5.4.2 Equipment containing work cells with MS3 parts N/A
8.5.4.2.1 Protection of persons in the work cell N/A
8.5.4.2.2 Access protection override N/A
8.5.4.2.2.1 Override system
N/A
8.5.4.2.2.2 Visual indicator
N/A
8.5.4.2.3 Emergency stop system
N/A
Maximum stopping distance from the point of
activation (m) ................................ ............................. : N/A
Space between end poi nt and nearest fixed
mechanical part (mm) ................................ ............... : N/A
8.5.4.2.4 Endurance requirements N/A
Mechanical system subjected to 100 000 cycles of
operation N/A
- Mechanical function check and visual inspection N/A
- Cable assembly ................................ ...................... : N/A
8.5.4.3 Equipment having electromechanical device for
destruction of media N/A
8.5.4.3.1 Equipment safeguards N/A
8.5.4.3.2 Instructional safeguards against moving parts ........ : N/A
8.5.4.3.3 Disconnection from the supply N/A
8.5.4.3.4 Cut type and test force (N) ................................ ........ : N/A
8.5.4.3.5 Compliance N/A
8.5.5 High pressure lamps No High pressure lamps N/A
Explosion test ................................ ............................ : N/A
8.5.5.3 Glass particles dimensions (mm) ............................. : N/A
8.6 Stability of equipment
N/A
Page 135 of 406

Page 25 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
8.6.1 General Built - in equipment N/A
Instructional safeguard ................................ .............. : N/ A
8.6.2 Static stability N/A
8.6.2.2 Static stability test ................................ ..................... : N/A
8.6.2.3 Downward force test N/A
8.6.3 Relocation stability N/A
Wheels diameter (mm) ................................ ............. :
Tilt test N/A
8.6.4 Glass slide test N/A
8.6.5 Horizontal force test ................................ .................. : N/A
8.7 Eq uipment mounted to wall, ceiling or other structure
N/A
8.7.1 Mount means type ................................ .................... : Built - in equipment N/A
8.7.2 Test methods N/A
Test 1, additional downwards force (N) .................... : N/A
Test 2, number of attachment points and test force
(N) ................................ ................................ .............. : N/A
Test 3 Nomin al diameter (mm) and applied torque
(Nm) ................................ ................................ ........... : N/A
8.8 Handles strength
N/A
8.8.1 General No such part N/A
8.8.2 Handle strength test N/A
Number of handles ................................ .................... :
Force applied (N) ................................ ...................... :
8.9 Wheels or casters attachment requirements
N/A
8.9.2 Pull t est No wheels or casters N/A
8.10 Carts, stands and similar carriers
N/A
8.10.1 General Built - in equipment N/A
8.10.2 Marking and instructions ................................ ........... : N/A
8.10.3 Cart, stand or carrier loading test N/A
Loading force applied (N) ................................ ......... : N/A
8.10.4 Cart, sta nd or carrier impact test N/A
8.10.5 Mechanical stability N/A
Force applied (N) ................................ ...................... :
Page 136 of 406

Page 26 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
8.10.6 Thermoplastic temperature stability N/A
8.11 Mounting means for slide - rail mounted equipment (SRME)
N/A
8.11.1 General N/A
8.11.2 Requirements for slide rails N/A
Instructional Safeguard ................................ ............. : N/A
8.11.3 Mechanical strength test N/A
8.11.3.1 Downward force test, force (N) applied .................... : N/A
8.11.3.2 Lateral push force test N/A
8.11.3.3 Integrity of slide rail end stops N/A
8.11.4 Compliance N/A
8.12 Telescoping or rod antennas
N/A
Button/ball diameter (mm) ................................ ........ :
9 THERMAL BURN INJURY
P
9.2 Thermal energy source classifications
P
9.3 Touch temperature limits
P
9.3.1 Touch temperatures of accessible parts .................. : (See appended table 9.3 ) P
9.3.2 Test method and compliance P
9.4 Safeguards against thermal energy sources
N/A
9.5 Requirements for safeguards
N/A
9.5.1 Equipment safeguard N/A
9.5.2 Instructional safeguard ................................ .............. : N/A
9.6 Requirements for wireless power transmitters
N/A
9.6.1 General N/A
9.6.2 Specification of the foreign objects N/A
9.6.3 Test method and compliance ................................ ... : N/A
10 RADIATION
P
10.2 Radiation energy source classification
P
10.2.1 General classification P
Lasers ................................ ................................ .... :