IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
For special national conditions, see Annex ZB.
1 Add the following note:
NOTE Z1 The use of certain substances in electrical and electronic
equipment is restricted within the EU: see Directive 2011/65/EU. P
4.Z1 Add the following new subclause after 4.9:
To protect against excessive current, short - circuits and
earth faults in circuits connected to an a.c. mains ,
protective devices shall be included either as integ ral
parts of the equipment or as parts of the building
installation, subject to the following, a), b) and c):
a) except as detailed in b) and c), protective devices
necessary to comply with the requirements of B.3.1 and
B.4 shall be included as parts of th e equipment;
b) for components in series with the mains input to the
equipment such as the supply cord, appliance coupler,
r.f.i. filter and switch, short - circuit and earth fault
protection may be provided by protective devices in the
building installation ;
c) it is permitted for pluggable equipment type B or
permanently connected equipment , to rely on
dedicated overcurrent and short - circuit protection in the
building installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fu lly
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so state,
except that for pluggable equipment type A the
building installation shall be regarded as provid ing
protection in accordance with the rating of the wall
socket outlet. N/A
5.4.2.3.2.4 Add the following to the end of this subclause:
The requirement for interconnection with external
circuit is in addition given in EN 50491 - 3:2009. N/A
10.2.1 Add th e following to c)
and d)
in table 39:
For additional requirements, see 10.5.1. N/A
Page 66 of 406

Page 61 of 90 Report No. : 60404487 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
10.5.1 Add the following after the first paragraph:
For RS 1 compliance is checked by measurement
under the following conditions:
In addition to the normal operating condi tions, all
controls adjustable from the outside by hand, by any
object such as a tool or a coin, and those internal
adjustments or presets which are not locked in a reliable
manner, are adjusted so as to give maximum radiation
whilst maintaining an intelli gible picture for 1 h, at the
end of which the measurement is made.
NOTE Z1 Soldered joints and paint lockings are examples of
adequate locking.
The dose - rate is determined by means of a radiation
monitor with an effective area of 10 cm², at any point 10
cm from the outer surface of the apparatus.
Moreover, the measurement shall be made under fault
conditions causing an increase of the high - voltage,
provided an intelligible picture is maintained for 1 h, at
the end of which the measurement is made.
For RS 1, the dose - rate shall not exceed 1 μSv/h taking
account of the background level.
NOTE Z2 These values appear in Directive 96/29/Euratom of 13 May
1996. N/A
10.6.1 Add the following paragraph to the end of the
subclause:
EN 71 - 1:2011, 4.20 and the relat ed tests methods and
measurement distances apply. N/A
10.Z1 Add the following new subclause after 10.6.5.
10.Z1 Non - ionizing radiation from radio frequencies
in the range 0 to 300 GHz
The amount of non - ionizing radiation is regulated by
European Council Recommendation 1999/519/EC of 12
July 1999 on the limitation of exposure of the general
public to electromagnetic fields (0 Hz to 300 GHz).
For intentional radiators, ICNIRP guidelines should be
taken into account for Limiting Exposure to Time -
Varying Elec tric, Magnetic, and Electromagnetic Fields
(up to 300 GHz). For hand - held and body - mounted
devices, attention is drawn to EN 50360 and EN 50566 N/A
G.7.1 Add the following note:
NOTE Z1 The harmonized code designations corresponding to the
IEC cord type s are given in Annex ZD. P
Page 67 of 406

Page 62 of 90 Report No. : 60404487 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
Bibliograph
y Add the following standards:
Add the following notes for the standards indicated:
IEC 60130 - 9 NOTE Harmonized as EN 60130 - 9.
IEC 60269 - 2 NOTE Harmonized as HD 60269 - 2.
IEC 60309 - 1 N OTE Harmonized as EN 60309 - 1.
IEC 60364 NOTE some parts harmonized in HD 384/HD 60364 series.
IEC 60601 - 2 - 4 NOTE Harmonized as EN 60601 - 2 - 4.
IEC 60664 - 5 NOTE Harmonized as EN 60664 - 5.
IEC 61032:1997 NOTE Harmonized as EN 61032:1998 (not modified).
IEC 61508 - 1 NOTE Harmonized as EN 61508 - 1.
IEC 61558 - 2 - 1 NOTE Harmonized as EN 61558 - 2 - 1.
IEC 61558 - 2 - 4 NOTE Harmonized as EN 61558 - 2 - 4.
IEC 61558 - 2 - 6 NOTE Harmonized as EN 61558 - 2 - 6.
IEC 61643 - 1 NOTE Harmonized as EN 61643 - 1.
IEC 61643 - 21 NOTE Harmonized as EN 61643 - 21.
IEC 61643 - 311 NOTE Harmonized as EN 61643 - 311.
IEC 61643 - 321 NOTE Harmonized as EN 61643 - 321.
IEC 61643 - 331 NOTE Harmonized as EN 61643 - 331. P
Page 68 of 406

Page 63 of 90 Report No. : 60404487 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN)
N/A
4.1.15 Denmark, Finland, Norway and Sweden
To the end of the subclause the following is added:
Class I pluggable equipment type A intended for
connection to other equipment or a network shall, if
safety relies on connection to reliable earthing or if
surge suppressors are connected between the network
terminals and accessible parts, have a marking stating
that the equipment shall be connected to an earthed
mains socket - outlet.
The marking text in the app licable countries shall be as
follows:
In Denmark : “Apparatets stikprop skal tilsluttes en
stikkontakt med jord som giver forbindelse til
stikproppens jord.”
In Finland : "Laite on liitettä vä suojakoskettimilla
varustettuun pistorasiaan"
In Norway : “Apparat et må tilkoples jordet stikkontakt”
In Sweden : “Apparaten skall anslutas till jordat uttag” N/A
4.7.3 United Kingdom
To the end of the subclause the following is added:
The torque test is performed using a socket - outlet
complying with BS 1363, and the pl ug part shall be
assessed to the relevant clauses of BS 1363. Also see
Annex G.4.2 of this annex N/A
5.2.2.2 Denmark
After the 2nd paragraph add the following:
A warning (marking safeguard ) for high touch current
is required if the touch current exceeds the limits of 3,5
mA a.c. or 10 mA d.c. N/A
Page 69 of 406

Page 64 of 90 Report No. : 60404487 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.4.11.1
and Annex
G Finland and Sweden
To the end of the subclause the following is added:
For separation of the telecommunication network from
earth the following is applicable:
If this insulation is solid, i ncluding insulation forming part
of a component, it shall at least consist of either
• two layers of thin sheet material, each of which shall
pass the electric strength test below, or
• one layer having a distance through insulation of at
least 0,4 mm, whi ch shall pass the electric strength test
below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no distance
through insulation requirement for the insulation
consisting of an insulating compound completely filling
the casing, so that clearances and creepage distances
do not exist, if the component passes the electric
strength test in accordance with the compliance clause
below and in addition
• passes the tests and inspection criteria of 5.4.8 with an
electric str ength test of 1,5 kV multiplied by 1,6 (the
electric strength test of 5.4.9 shall be performed using
1,5 kV), and
• is subject to routine testing for electric strength during
manufacturing, using a test voltage of 1,5kV.
It is permitted to bridge this insu lation with a capacitor
complying with EN 60384 - 14:2005, subclass Y2.
A capacitor classified Y3 according to EN 60384 -
14:2005, may bridge this insulation under the following
conditions:
• the insulation requirements are satisfied by having a
capacitor clas sified Y3 as defined by EN 60384 - 14,
which in addition to the Y3 testing, is tested with an
impulse test of 2,5 kV defined in 5.4.11;
• the additional testing shall be performed on all the test
specimens as described in EN 60384 - 14;
the impulse test of 2,5 kV is to be performed before the
endurance test in EN 60384 - 14, in the sequence of
tests as described in EN 60384 - 14. N/A
5.5.2.1 Norway
After the 3rd paragraph the following is added:
Due to the IT power system used, capacitors are
required to be rated for the applicable line - to - line
voltage (230 V). N/A
Page 70 of 406

Page 65 of 90 Report No. : 60404487 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.5.6 Finland, Norway and Sweden
To the end of the subclause the following is added:
Resistors used as basic safeguard or bridging basic
insulation in class I pluggable equipment type A
shall comply w ith G.10.1 and the test of G.10.2. N/A
5.6.1 Denmark
Add to the end of the subclause
Due to many existing installations where the socket -
outlets can be protected with fuses with higher rating
than the rating of the socket - outlets the protection for
plugg able equipment type A shall be an integral part of
the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse. N/A
5.6.4.2.1 Ireland and United Kingdom
After the indent for pluggable equipment type A , the
foll owing is added:
– the protective current rating is taken to be 13 A, this
being the largest rating of fuse used in the mains plug. N/A
5.6.5.1 To the second paragraph the following is added:
The range of conductor sizes of flexible cords to be
accepted b y terminals for equipment with a rated
current over 10 A and up to and including 13 A is:
1,25 mm 2
to 1,5 mm 2
in cross - sectional area. N/A
5.7.5 Denmark
To the end of the subclause the following is added:
The installation instruction shall be affixed to the
equipment if the protective conductor current
exceeds the limits of 3,5 mA a.c. or 10 mA d.c. N/A
Page 71 of 406

Page 66 of 90 Report No. : 60404487 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.7.6.1 Norway and Sweden
To the end of the subclause the following is added:
The screen of the television distribution system is
normally not earthed a t the entrance of the building and
there is normally no equipotential bonding system within
the building. Therefore the protective earthing of the
building installation needs to be isolated from the screen
of a cable distribution system.
It is however acce pted to provide the insulation external
to the equipment by an adapter or an interconnection
cable with galvanic isolator, which may be provided by a
retailer, for example.
The user manual shall then have the following or similar
information in Norwegian a nd Swedish language
respectively, depending on in what country the
equipment is intended to be used in:
“Apparatus connected to the protective earthing of the
building installation through the mains connection or
through other apparatus with a connection t o protective
earthing – and to a television distribution system using
coaxial cable, may in some circumstances create a fire
hazard. Connection to a television distribution system
therefore has to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728 - 11)”
NOTE In Norway, due to regulation for CATV - installations, and in
Sweden, a galvanic isolator shall provide electrical insulation below 5
MHz. The insulation shall withstand a dielectric strength of 1,5 kV
r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also be
accepted in Norway):
“Apparater som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr – og er
tilkoplet et ko aksialbasert kabel - TV nett, kan forårsake
brannfare. For å unngå dette skal det ved tilkopling av
apparater til kabel - TV nett installeres en galvanisk
isolator mellom apparatet og kabel - TV nettet.”
Translation to Swedish:
”Apparater som är kopplad till sk yddsjord via jordat
vä gguttag och/eller via annan utrustning och samtidigt
är kopplad till kabel - TV nät kan i viss a fall medfőra risk
főr brand. Főr att undvika detta skall vid anslutning av
apparaten till kabel - TV nät galvanisk isolator finnas
mellan apparaten och kabel - TV nätet.”. N/A
Page 72 of 406

Page 67 of 90 Report No. : 60404487 001
IEC 62368 - 1 – ATTACHMENT 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.7.6.2 Denmark
To the end of the subclause the following is added:
The warning (marking safeguard) for high touch current
is required if the touch current or the protective current
exceed the limits of 3,5 mA . N/A
B.3.1 and
B.4 Ireland and United Kingdom
The following is applicable:
To protect against excessive currents and short - circuits
in the primary circuit of direct plug - in equipment , tests
according to Annexes B.3.1 and B.4 shall be conducted
using an external miniature circuit breaker complying
with EN 60898 - 1, Type B, rated 32A. If the equipment
does not pass these tests, s uitable protective devices
shall be included as an integral part of the direct plug -
in equipment , until the requirements of Annexes B.3.1
and B.4 are met N/A
G.4.2 Denmark
To the end of the subclause the following is added:
Supply cords of single phase a ppliances having a rated
current not exceeding 13 A shall be provided with a plug
according to DS 60884 - 2 - D1:2011.
CLASS I EQUIPMENT provided with socket - outlets with earth
contacts or which are intended to be used in locations where
protection against ind irect contact is required according to the
wiring rules shall be provided with a plug in accordance with
standard sheet DK 2 - 1a or DK 2 - 5a.
If a single - phase equipment having a RATED CURRENT
exceeding 13 A or if a poly - phase equipment is provided with
a su pply cord with a plug, this plug shall be in accordance with
the standard sheets DK 6 - 1a in DS 60884 - 2 - D1 or EN 60309 -
2.
Mains socket outlets intended for providing power to
Class II apparatus with a rated current of 2,5 A shall be
in accordance DS 60884 - 2 - D1:2011 standard sheet
DKA 1 - 4a.
Other current rating socket outlets shall be in
compliance with Standard Sheet DKA 1 - 3a or DKA 1 -
1c.
Mains socket - outlets with earth shall be in compliance
with DS 60884 - 2 - D1:2011 Standard Sheet DK 1 - 3a, DK
1 - 1c, DK1 - 1d, D K 1 - 5a or DK 1 - 7a
Justification:
Heavy Current Regulations, Section 6c N/A