Page 9 of 406

Page 4 of 90 Report No. : 60404487 001
TR F No. IEC62368_1 C
Summary of testing:
Tests p erformed (name of test and test clause):
All applicable tests as described in the test cases
and measurement sections were performed.
See test case and appended table for details.
This CB standard update test report is based on
CB test report No. 50040903 001, 50040903 002 ,
50040903 003, 50040903 004 and 50040903 005
with the certificate No. JPTUV - 071 619,
JPTUV - 071619 - A1 , JPTUV - 071619 - A1/M1,
JPTUV - 071619 - A2/M1 and JPTUV - 071619 - A2/M2.
No technical changes in between as declared by
the manufacturer except f or:
- Check and update certificate validity of critical
components and,
- Additional tests and evaluation per the new
standard edition requirement. Testing location:
TÜ V Rheinland Korea Ltd.
Young City, N - Tower, 25, Mullae - ro 28 - gil,
Yeongdeungpo - gu, Seoul #07298 Korea, Rep . of
Additional test and evaluation:
- Cl.5.2 Classification of electrical energy sources
- Cl. 6.2.2 Electrical Power Source (PS)
measurements for classification
- Annex B.2.5 Input test
- Annex B.3, B.4 Abnormal operating an d fault
condition tests
- Annex E Test conditions for equipment containing
audio amplifiers
- Annex T.8 Stress relief test
Summary of compliance with National Differences (List of countries addressed):
- EU Group Differences
The produ ct fulfils the requirements of EN 62368 - 1:2014/A11:2017 and EN IEC 62368 -
1:2020+A11:2020 .
Page 10 of 406
Page 5 of 90 Report No. : 60404487 001
TR F No. IEC62368_1 C
Copy of marking plate :
The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
Page 11 of 406
Page 6 of 90 Report No. : 60404487 001
TR F No. IEC62368_1 C
Page 12 of 406
Page 7 of 90 Report No. : 60404487 001
TR F No. IEC62368_1 C
Page 13 of 406

Page 8 of 90 Report No. : 60404487 001
TR F No. IEC62368_1 C
T est item particulars :
CAR AUDIO
Product group ................................ ..................... : end product built - in component
Classification of use by ................................ ....... : Ordinary person Children likely present
Instructed person
Skilled person
Supply c onnection ................................ ............... : AC mains DC mains
not mains connected :
ES1 ES2 ES3
Supply t olerance ................................ ................. : +10%/ - 10%
+20%/ - 15%
+ %/ - %
None
Supply c onnection – t ype ................................ .. : pluggable equipment type A -
non - detachable supply cord
appliance coupler
direct plug - in
pluggable equipment type B -
non - detachable supply cord
appliance coupler
p ermanent connection
mating connector other: PS3,ES1 (EV battery)
Considered current rating of protective device
................................ ................................ ............ : A;
Location: building equipment
N/A
Equipment mobility ................................ .......... : movable hand - held transportable
direct plug - in stationary for building - in
wall /c eiling - mounted SRME/rack - mounted
other:
Overvoltage c ategory (OVC) ........................... : OVC I OVC II OVC III
OVC IV other: EV battery
Class of equipment ................................ .......... : Class I Class II Class III
Not classif ied
Special installation location ........................... : N/A restricted access area
outdoor location
Pollution degree (PD) ................................ ...... :
PD 1 PD 2 PD 3
Manufacturer’s specified T
ma ........................... :
85 °C Outdoor: minimum °C
IP protection class ................................ ........... :
IPX0 IP___
Power s ystems ................................ ................. : TN TT IT - V
L - L
not AC mains
Altitude during operation (m) ......................... :
2000 m or less 5000 m
Altitude of test laboratory (m) ........................ :
2000 m or less m
Mass of equipment (kg) ................................ ... : 1. 6 5 kg
Page 14 of 406

Page 9 of 90 Report No. : 60404487 001
TR F No. IEC62368_1 C
P ossible test case verdicts :
- test case does not apply to the test object .... :
N/A
- test object does meet the requirement ........... :
P (Pass)
- test object does not meet the req uirement .... :
F (Fail)
T esting :
Date of receipt of test item ................................ . :
27.07 .2020
Date (s) of performance of tests ........................ :
1 3 .0 8 .2020 to 14 .0 8 .2020
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
Manufacturer’s Declaration per sub - clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ................................ ................ : Yes
Not applicable
When differences exist ; they shall be identified in the General product information section.
Page 15 of 406

Page 10 of 90 Report No. : 60404487 001
TR F No. IEC62368_1 C
Name and address of factory (ies) ................. :
Factory #1. LG Electronics Vietnam Hai Phong Co., Ltd.
Lot CN2, Trang Due Industrial Park, Le Loi Com mune, An Duong District, Hai Phong City,
Vietnam
Factory #2. LG INNOTEK YANTAI CO., LTD.
No. 36, Taibei North Road, Development Zone, Yantai 264006 Shandong P.R. China
Factory #3. LG Electronics Mława Sp. z o.o.
ul. LG Electronics 7 06 - 500 Mława Poland
Fac tory #4. LG Electronics Inc.
222, LG - ro, Jinwi - myeon Pyeongtaek - si, Gyeonggi - do 17709 Republic of Korea
Factory #5. LG Electronics(Kunshan) Co., Ltd.
No. 88, Qianjin East Road, Kunshan City 215300 Jiangsu P.R. China
Factory #6. LG ELECTRONICS DO BRASIL LTD A
LG - FILIAL MANAUS RUA JAVARI 1004 DISTRITO INDUSTRIAL MANAUS - AM, 69075 - 110,
Brazil
Factory #7. LG Electronics Nanjing Vehicle Component Co., Ltd.
No.346, Yaoxinda Road, Nanjing Economic and Technological Development Zone, 210038,
P.R. China
Factory #8 . Hitachi - LG Data Storage(Huizhou), Ltd.
Huifeng Fourth Road 42, Zhongkai Hi - Tech Industry Development Zone, Huizhou, Guangdong,
516006 P.R. China
Factory #9. HITACHI ELECTRONIC PRODUCTS (M) SDN. BHD
No. 12, Jalan Kemajuan, Bangi Industrial Estate, 43650 B andar Baru Bangi,
Selangor Darul Ehsan, Malaysia
Page 16 of 406

Page 11 of 90 Report No. : 60404487 001
TR F No. IEC62368_1 C
General product information and other remarks:
This product(CAR AUDIO) is a building - in type as component which has Bluetooth, Radio and DAB
functions.
It is Class III equipment supplied by a 12 V EV b attery.
It is intended to be built in a vehicle by an instructed person or skilled person as service person and user’s
manual shall be provided in the end equipment.
The Model L60SK2 is basic model and the model MIB2GP is identical to the basic model excep t for model
designation .
The models L81SK2, L73SK2 and L72SK2 are similar to the basic model except for model designation and
front enclosure design. It doe s not affect to safety factor.
The maximum ambient temperature permitted by the manufacturer (Tma): 85 o
C
This report is for standard up - date from IEC 60065:2014 to IEC 62368 - 1:2018 by earlier test report No.
50040903 001, 50040903 002, 50040903 003, 50040903 004 and 50040903 005 with the certificate
No. JPTUV - 071619, JPTUV - 071619 - A1, JPTUV - 071619 - A1/M1 , JPTUV - 071619 - A2/M1 and
JPTUV - 071619 - A2/M2.
The samples submitted for evaluation are representative of the final product and have the same quality in
items of safety aspect from each factory.
When installing, all the requirements of IEC 62368 - 1 must be f ulfilled.