Page 15 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4 GENERAL REQUIREMENTS
P
4.1.1 Acceptance of materials, components and
subassemblies (See appended table 4.1.2) P
4.1.2 Use of components
The equipment is so designed
and constructed that, under
normal operating conditions
(see Clause B.2), abnormal
operating conditions (see
Clause B.3), and single fault
conditions (see Clause B.4),
safeguards are provided to
red uce the likelihood of injury
or, in the case of fire, property
damage P
4.1.3 Equipment design and construction
P
4.1.4 Specified ambient temperature for outdoor use ( o
C)
................................ ................................ .................... : Not intended for outdoor use N/A
4.1.5 Constructions and components not specifi cally
covered N/A
4.1.8 Liquids and liquid filled components (LFC) N/A
4.1.15 Markings and instructions (See Annex F) P
4.4.3 Safeguard robustness P
4.4.3.1 General P
4.4.3.2 Steady force tests Building - in equipment N/A
4.4.3.3 Drop tests Buildi ng - in equipment N/A
4.4.3.4 Impact tests P
4.4.3.5 Internal accessible safeguard tests No Internal accessible
safeguard is used N/A
4.4.3.6 Glass impact tests No glass in the equipment N/A
4.4.3.7 Glass fixation tests No laminated glass used N/A
Gl ass impact test (1J) N/A
Push/pull test (10 N) N/A
4.4.3.8 Thermoplastic material tests P
4.4.3.9 Air comprising a safeguard N/A
4.4.3.10 Accessibility, glass, safeguard effectiveness P
4.4.4 Displacement of a safeguard by an insulating liquid N o insulating liquid used N/A
4.4.5 Safety interlocks No Safety interlocks N/A
Page 22 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.7.5 Earthed accessible conductive parts ..................... : N/A
5.7.6 Requirements when touch current exceeds ES2
limits N/A
Protective c onductor current (mA) ......................... : N/A
Instructional Safeguard ................................ .......... : N/A
5.7.7 Prospective touch voltage and touch current
associated with external circuits N/A
5.7.7.1 Touch current from coaxial cables N/A
5.7.7.2 Prospective touch voltage and touch current
ass ociated with paired conductor cables N/A
5.7.8 Summation of touch currents from external circuits N/A
a) Equipment connected to earthed external
circuits, current (mA) ................................ ............. : N/A
b) Equipment connected to unearthed external
circuits, current (mA) ................................ ............. : N/A
5.8 Backfeed safeguard in battery backed up supplies
N/ A
Mains terminal ES ................................ ..................... : No battery backed up supplies N/ A
Air gap (mm) ................................ .............................. : N/ A
6 ELECTRICALLY - CAUSED FIRE
P
6.2 Classification of PS and PIS
P
6.2.2 Power source circuit classifications .......................... : (See appended table 6.2.2) P
6.2.3 Classification of potential ignition sources P
6.2.3.1 Arcing PIS ................................ ................................ : Open circuit voltage does not
exceed 50 V N/A
6.2.3.2 Resistive PIS ................................ ............................ : (See appended table 6.2.3.2) P
6.3 Safeguards against fire under normal operatin g and abnormal operating
conditions P
6.3.1 No ignition and attainable temperature value less
than 90 % defined by ISO 871 or less than 300 C
for unknown materials ................................ ........... : No ignition and no such
temperature attained within
the equipment P
Combustible materi als outside fire enclosure .......... : Min. HB P
6.4 Safeguards against fire under single fault conditions
P
6.4.1 Safeguard method Control fire spread P
6.4.2 Reduction of the likelihood of ignition under single
fault conditions in PS1 circuits N/A
Page 43 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
d) Overcurrent protective device limited output N/A
e) IC current limiter complying with G.9 N/A
Q.1.2 Test method and compliance ................................ : (See appended table Q.1) P
Current rating of overcurrent prot ective device (A)
................................ ................................ ............... : N/A
Q.2 Test for external circuits – paired conductor
cable N/A
Maximum output current (A) ................................ . : N/A
Current limiting method ................................ ......... :
R LIMITED SHORT CIRCUIT TEST
N/A
R.1 General
N/A
R.2 Test setup
N/A
Overcurrent protective d evice for test ................... :
R.3 Test method
N/A
Cord/cable used for test ................................ ........ :
R.4 Compliance
N/A
S TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
S.1 Flammability test for fire enclosures and fire barrier materials of equipment
where the steady state power does not exceed 4 000 W N/A
Samples, material ................................ .................. :
Wall thickness (mm) ................................ .............. :
Conditioning ( C) ................................ ................... :
Test flame according to IEC 60695 - 11 - 5 with
conditions as set out N/A
- Material not consumed completely N/A
- Material extinguishes within 30s N/ A
- No burning of layer or wrapping tissue N/A
S.2 Flammability test for fire enclosure and fire barrier integrity
N/A
Samples, material ................................ .................. :
Wall thickness (mm) ................................ .............. :
Conditioning ( C) ................................ ................... :
S.3 Flammability test for the bottom of a fire enclosu re
N/A
S.3.1 Mounting of samples N/A
S.3.2 Test method and compliance N/A
Page 14 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4 GENERAL REQUIREMENTS
P
4.1.1 Acceptance of materials, components and
subassemblies (See appended table 4.1.2) P
4.1.2 Use of components
The equipment is so de signed
and constructed that, under
normal operating conditions
(see Clause B.2), abnormal
operating conditions (see
Clause B.3), and single fault
conditions (see Clause B.4),
safeguards are provided to
reduce the likelihood of injury
or, in the case of fi re, property
damage P
4.1.3 Equipment design and construction
P
4.1.4 Specified ambient temperature for outdoor use ( o
C)
................................ ................................ .................... : Not intended for outdoor use N/A
4.1.5 Constructions and components not specifically
covered N/A
4.1.8 Liquids and liquid fille d components (LFC) N/A
4.1.15 Markings and instructions (See Annex F) P
4.4.3 Safeguard robustness P
4.4.3.1 General P
4.4.3.2 Steady force tests Building - in equipment N/A
4.4.3.3 Drop tests Building - in equipment N/A
4.4.3.4 Impact tests P
4.4. 3.5 Internal accessible safeguard tests No Internal accessible
safeguard is used N/A
4.4.3.6 Glass impact tests No glass in the equipment N/A
4.4.3.7 Glass fixation tests No laminated glass used N/A
Glass impact test (1J) N/A
Push/pull test (10 N) N/A
4.4.3.8 Thermoplastic material tests P
4.4.3.9 Air comprising a safeguard N/A
4.4.3.10 Accessibility, glass, safeguard effectiveness P
4.4.4 Displacement of a safeguard by an insulating liquid No insulating liquid used N/A
4.4.5 Safety interlo cks No Safety interlocks N/A
Page 21 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.7.5 Earthed accessible conductive parts ..................... : N/A
5.7.6 Requirements when touch current exceeds ES2
limits N/A
Protective conductor current (mA) ......................... : N/A
Instructional Safeg uard ................................ .......... : N/A
5.7.7 Prospective touch voltage and touch current
associated with external circuits N/A
5.7.7.1 Touch current from coaxial cables N/A
5.7.7.2 Prospective touch voltage and touch current
associated with paired conductor cables N/A
5.7.8 S ummation of touch currents from external circuits N/A
a) Equipment connected to earthed external
circuits, current (mA) ................................ ............. : N/A
b) Equipment connected to unearthed external
circuits, current (mA) ................................ ............. : N/A
5.8 Backfeed safeguard in battery backed up supp lies
N/ A
Mains terminal ES ................................ ..................... : No battery backed up supplies N/ A
Air gap (mm) ................................ .............................. : N/ A
6 ELECTRICALLY - CAUSED FIRE
P
6.2 Classification of PS and PIS
P
6.2.2 Power source circuit classifications .......................... : (See appended table 6.2.2) P
6.2.3 Classification of potential ignition sources P
6.2.3.1 Arcing PIS ................................ ................................ : Open circuit voltage does not
exceed 50 V N/A
6.2.3.2 Resistive PIS ................................ ............................ : (See appended table 6.2.3.2) P
6.3 Safeguards against fire under normal operating and abnormal operating
conditions P
6.3.1 No ig nition and attainable temperature value less
than 90 % defined by ISO 871 or less than 300 C
for unknown materials ................................ ........... : No ignition and no such
temperature attained within
the equipment P
Combustible materials outside fire enclosure .......... : Min. HB P
6.4 Safeg uards against fire under single fault conditions
P
6.4.1 Safeguard method Control fire spread P
6.4.2 Reduction of the likelihood of ignition under single
fault conditions in PS1 circuits N/A
Page 42 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
d) Overcurrent protective device limited output N/A
e) IC current limiter complying with G.9 N/A
Q.1.2 Test method and compliance ................................ : (See appended table Q.1) P
Current rating of overcurrent protective device (A)
................................ ................................ ............... : N/A
Q.2 Test for external circuits – paired conductor
cable N/A
Maximum output current (A) ................................ . : N/A
Current limiting method ................................ ......... :
R LIMITED SHORT CIRCUIT TEST
N/A
R.1 General
N/A
R.2 Test setup
N/A
Overcurrent protective device for test ................... :
R.3 Test method
N/A
Cord /cable used for test ................................ ........ :
R.4 Compliance
N/A
S TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
S.1 Flammability test for fire enclosures and fire barrier materials of equipment
where the steady state power does not exceed 4 000 W N/A
Samples, material ................................ .................. :
Wall thickness (mm) ................................ .............. :
Conditioning ( C) ................................ ................... :
Test flame according to IEC 60695 - 11 - 5 with
conditions as set out N/A
- Material not consumed completely N/A
- Material extinguishes within 30s N/A
- No burning of layer or wrapping tissue N/ A
S.2 Flammability test for fire enclosure and fire barrier integrity
N/A
Samples, material ................................ .................. :
Wall thickness (mm) ................................ .............. :
Conditioning ( C) ................................ ................... :
S.3 Flammability test for the bottom of a fire enclosure
N/A
S.3.1 Mounting of samples N/A
S.3.2 T est method and compliance N/A
Page 13 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4 GENERAL REQUIREMENTS
P
4.1.1 Acceptance of materials, components and
subassemblies (See appended table 4.1.2) P
4.1.2 Use of components
The equipment is so designed
and constructed that, under
normal ope rating conditions
(see Clause B.2), abnormal
operating conditions (see
Clause B.3), and single fault
conditions (see Clause B.4),
safeguards are provided to
reduce the likelihood of injury
or, in the case of fire, property
damage P
4.1.3 Equipment design and construction
P
4.1.4 Specified ambient temperature for outdoor use ( o
C)
................................ ................................ .................... : Not intended for outdoor use N/A
4.1.5 Constructions and components not specifically
covered N/A
4.1.8 Liquids and liquid filled components (LFC) N/A
4.1.15 Markings and instructions (See Annex F) P
4.4.3 Safeguard robustness P
4.4.3.1 General P
4.4.3.2 Steady force tests Building - in equipment N/A
4.4.3.3 Drop tests Building - in equipment N/A
4.4.3.4 Impact tests P
4.4.3.5 Internal accessible safeguard tests No In ternal accessible
safeguard is used N/A
4.4.3.6 Glass impact tests No glass in the equipment N/A
4.4.3.7 Glass fixation tests No laminated glass used N/A
Glass impact test (1J) N/A
Push/pull test (10 N) N/A
4.4.3.8 Thermoplastic material tests P
4.4.3.9 Air comprising a safeguard N/A
4.4.3.10 Accessibility, glass, safeguard effectiveness P
4.4.4 Displacement of a safeguard by an insulating liquid No insulating liquid used N/A
4.4.5 Safety interlocks No Safety interlocks N/A
Page 20 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.7.5 Earthed accessible conductive parts ..................... : N/A
5.7.6 Requirements when touch current exceeds ES2
limits N/A
Protective conductor current (mA) ......................... : N/A
Instructional Safeguard ................................ .......... : N/A
5.7.7 Prospective touch voltage and touch current
associated with external circuits N/A
5.7.7.1 Touch current from coaxial cables N/A
5.7.7.2 Prospective touch voltage and touch current
associated with paired conductor cables N/A
5.7.8 Summation of touch currents from external circ uits N/A
a) Equipment connected to earthed external
circuits, current (mA) ................................ ............. : N/A
b) Equipment connected to unearthed external
circuits, current (mA) ................................ ............. : N/A
5.8 Backfeed safeguard in battery backed up supplies
N/ A
Mains terminal ES ................................ ..................... : No battery bac ked up supplies N/ A
Air gap (mm) ................................ .............................. : N/ A
6 ELECTRICALLY - CAUSED FIRE
P
6.2 Classification of PS and PIS
P
6.2.2 Power source circuit classifications .......................... : (See appended table 6.2.2) P
6.2.3 Classification of potential ignition sources P
6.2.3.1 Arcing PIS ................................ ................................ : Open circuit voltage does not
exceed 50 V N/A
6.2.3.2 Resistive PIS ................................ ............................ : (See appended table 6.2.3.2) P
6.3 Safeguards against fire under normal operating and abnormal operating
conditions P
6.3.1 No ignition and attainable temperature value less
than 90 % defined by ISO 871 or less than 300 C
for unknown materials ................................ ........... : No ignition and no such
temperature attained within
the equipment P
Combustible materials outside fire enclosure .......... : Min. HB P
6.4 Safeguards against fire under single fault conditi ons
P
6.4.1 Safeguard method Control fire spread P
6.4.2 Reduction of the likelihood of ignition under single
fault conditions in PS1 circuits N/A