Page 15 of 90 Report No. : 60404487 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4 GENERAL REQUIREMENTS
P
4.1.1 Acceptance of materials, components and
subassemblies (See appended table 4.1.2) P
4.1.2 Use of components
The equipment is so designed
and constructed that, under
normal operating conditions
(see Clause B.2), abnormal
operating conditions (see
Clause B.3), and single fault
conditions (see Clause B.4),
safeguards are provided to
red uce the likelihood of injury
or, in the case of fire, property
damage P
4.1.3 Equipment design and construction
P
4.1.4 Specified ambient temperature for outdoor use ( o
C)
................................ ................................ .................... : Not intended for outdoor use N/A
4.1.5 Constructions and components not specifi cally
covered N/A
4.1.8 Liquids and liquid filled components (LFC) N/A
4.1.15 Markings and instructions (See Annex F) P
4.4.3 Safeguard robustness P
4.4.3.1 General P
4.4.3.2 Steady force tests Building - in equipment N/A
4.4.3.3 Drop tests Buildi ng - in equipment N/A
4.4.3.4 Impact tests P
4.4.3.5 Internal accessible safeguard tests No Internal accessible
safeguard is used N/A
4.4.3.6 Glass impact tests No glass in the equipment N/A
4.4.3.7 Glass fixation tests No laminated glass used N/A
Gl ass impact test (1J) N/A
Push/pull test (10 N) N/A
4.4.3.8 Thermoplastic material tests P
4.4.3.9 Air comprising a safeguard N/A
4.4.3.10 Accessibility, glass, safeguard effectiveness P
4.4.4 Displacement of a safeguard by an insulating liquid N o insulating liquid used N/A
4.4.5 Safety interlocks No Safety interlocks N/A
Page 14 of 89 Report No. : 60404488 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4 GENERAL REQUIREMENTS
P
4.1.1 Acceptance of materials, components and
subassemblies (See appended table 4.1.2) P
4.1.2 Use of components
The equipment is so de signed
and constructed that, under
normal operating conditions
(see Clause B.2), abnormal
operating conditions (see
Clause B.3), and single fault
conditions (see Clause B.4),
safeguards are provided to
reduce the likelihood of injury
or, in the case of fi re, property
damage P
4.1.3 Equipment design and construction
P
4.1.4 Specified ambient temperature for outdoor use ( o
C)
................................ ................................ .................... : Not intended for outdoor use N/A
4.1.5 Constructions and components not specifically
covered N/A
4.1.8 Liquids and liquid fille d components (LFC) N/A
4.1.15 Markings and instructions (See Annex F) P
4.4.3 Safeguard robustness P
4.4.3.1 General P
4.4.3.2 Steady force tests Building - in equipment N/A
4.4.3.3 Drop tests Building - in equipment N/A
4.4.3.4 Impact tests P
4.4. 3.5 Internal accessible safeguard tests No Internal accessible
safeguard is used N/A
4.4.3.6 Glass impact tests No glass in the equipment N/A
4.4.3.7 Glass fixation tests No laminated glass used N/A
Glass impact test (1J) N/A
Push/pull test (10 N) N/A
4.4.3.8 Thermoplastic material tests P
4.4.3.9 Air comprising a safeguard N/A
4.4.3.10 Accessibility, glass, safeguard effectiveness P
4.4.4 Displacement of a safeguard by an insulating liquid No insulating liquid used N/A
4.4.5 Safety interlo cks No Safety interlocks N/A
Page 13 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4 GENERAL REQUIREMENTS
P
4.1.1 Acceptance of materials, components and
subassemblies (See appended table 4.1.2) P
4.1.2 Use of components
The equipment is so designed
and constructed that, under
normal ope rating conditions
(see Clause B.2), abnormal
operating conditions (see
Clause B.3), and single fault
conditions (see Clause B.4),
safeguards are provided to
reduce the likelihood of injury
or, in the case of fire, property
damage P
4.1.3 Equipment design and construction
P
4.1.4 Specified ambient temperature for outdoor use ( o
C)
................................ ................................ .................... : Not intended for outdoor use N/A
4.1.5 Constructions and components not specifically
covered N/A
4.1.8 Liquids and liquid filled components (LFC) N/A
4.1.15 Markings and instructions (See Annex F) P
4.4.3 Safeguard robustness P
4.4.3.1 General P
4.4.3.2 Steady force tests Building - in equipment N/A
4.4.3.3 Drop tests Building - in equipment N/A
4.4.3.4 Impact tests P
4.4.3.5 Internal accessible safeguard tests No In ternal accessible
safeguard is used N/A
4.4.3.6 Glass impact tests No glass in the equipment N/A
4.4.3.7 Glass fixation tests No laminated glass used N/A
Glass impact test (1J) N/A
Push/pull test (10 N) N/A
4.4.3.8 Thermoplastic material tests P
4.4.3.9 Air comprising a safeguard N/A
4.4.3.10 Accessibility, glass, safeguard effectiveness P
4.4.4 Displacement of a safeguard by an insulating liquid No insulating liquid used N/A
4.4.5 Safety interlocks No Safety interlocks N/A
Page 13 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
4 GENERAL REQUIREMENTS
P
4.1.1 Acceptance of materials, components and
subassemblies (See appended table 4.1.2) P
4.1.2 Use of components
The equipment is so designed
and constructed that, under
normal ope rating conditions
(see Clause B.2), abnormal
operating conditions (see
Clause B.3), and single fault
conditions (see Clause B.4),
safeguards are provided to
reduce the likelihood of injury
or, in the case of fire, property
damage P
4.1.3 Equipment design and construction
P
4.1.4 Specified ambient temperature for outdoor use ( o
C)
................................ ................................ .................... : Not intended for outdoor use N/A
4.1.5 Constructions and components not specifically
covered N/A
4.1.8 Liquids and liquid filled components (LFC) N/A
4.1.15 Markings and instructions (See Annex F) P
4.4.3 Safeguard robustness P
4.4.3.1 General P
4.4.3.2 Steady force tests Building - in equipment N/A
4.4.3.3 Drop tests Building - in equipment N/A
4.4.3.4 Impact tests P
4.4.3.5 Internal accessible safeguard tests No In ternal accessible
safeguard is used N/A
4.4.3.6 Glass impact tests No glass in the equipment N/A
4.4.3.7 Glass fixation tests No laminated glass used N/A
Glass impact test (1J) N/A
Push/pull test (10 N) N/A
4.4.3.8 Thermoplastic material tests P
4.4.3.9 Air comprising a safeguard N/A
4.4.3.10 Accessibility, glass, safeguard effectiveness P
4.4.4 Displacement of a safeguard by an insulating liquid No insulating liquid used N/A
4.4.5 Safety interlocks No Safety interlocks N/A