2012 SSANGYONG RODIUS Service Manual

Page 345 of 715

SSANGYONG RODIUS 2012  Service Manual 15-20
MDP (Minimum Drive Pulse ) refers to the 
minimum power supply pulse for injection which 
the injector can perform. It is possible to control 
the fuel volume for each injector accurately 
throu

Page 346 of 715

SSANGYONG RODIUS 2012  Service Manual 15-210000-00
C. Learning Conditions
Idle MDP learning Drive MDP learning
Coolant temperatureover 60℃   over 60℃ 
Vehicle speedIdling over 50km/h (over 5 seconds)
Engine rpm2,000 to 2,500 rpm 
Fuel

Page 347 of 715

SSANGYONG RODIUS 2012  Service Manual 15-22
(7) Knocking Control
A. Resetting the pilot injection
The knocking control is used to reset the pilot injection flow in closed loop for each injector. This method 
allows the correction of any i

Page 348 of 715

SSANGYONG RODIUS 2012  Service Manual 15-230000-00
This is done periodically under certain operating conditions. When the resetting is finished, the new 
minimum pulse value replaces the value obtained during the previous resetting. The f

Page 349 of 715

SSANGYONG RODIUS 2012  Service Manual 15-24
(8) Swirl control
A. Overview
Variable swirl valve ▶
The strong swirl caused by intake air is important element for anti-locking function in diesel engine. The 
swirl control valve partially c

Page 350 of 715

SSANGYONG RODIUS 2012  Service Manual 15-250000-00
B.  Input/Output for variable swirl valve

Page 351 of 715

SSANGYONG RODIUS 2012  Service Manual 15-26
C. Types of swirl
Swirl: One cylinder has two intake air ports, one is set horizontally and 
the other one is set vertically. Swirl is the horizontal air flows in cylinder 
due to the horizontal

Page 352 of 715

SSANGYONG RODIUS 2012  Service Manual 15-270000-00
Load Engine speedSwirl 
valveAmount of 
swirlRemarks
Low speed,
Low loadbelow 3,000 rpm Closed HeavyIncreased EGR ratio, better air-fuel 
mixture (reduce exhaust gas))
High speed,
High lo