SSANGYONG RODIUS 2012  Service Manual 01-190000-00
8. ELECTRIC COMPONENTS AND LAYOUT
1) Wiring Harness Arrangement

Page 156 of 715

SSANGYONG RODIUS 2012  Service Manual 01-14
Name SizeNumbers of 
fastenerTightening 
torque (Nm)Note (total 
tightening 
torque)
Idler pulley/tensioner 
pulley1 45±4.5Nm - 
Glow plug M5  4 20±2Nm - 
Vacuum pumpM8×25 3 10±1Nm - 
Timing

Page 163 of 715

SSANGYONG RODIUS 2012  Service Manual 02-6
Cylinder head coverM6×352110±1Nm-
Oil gauge tubeM6×16110±1Nm-
Oil filter cap 125±2.5Nm-
Fuel railM8×25225±2.5Nm-
Injector clamp boltM6×4429±1.0Nm
130˚±10˚-
High pressure pipe 
(betwee

Page 164 of 715

SSANGYONG RODIUS 2012  Service Manual 02-70000-00
3. CHECK AND INSPECTION
1) Cylinder
(1) Compression pressure test
Specified value ▶
Compression ratio16.5 : 1 
Test conditionat normal operating temperature (80˚C)
Compression pressur
e

Page 214 of 715

SSANGYONG RODIUS 2012  Service Manual 03-10
(3) DI Engine Fuel System Check Procedure
If several DTCs are output simultaneously, check the electric wiring for open or short circuit. 
Check the low pressure fuel system and fuel filter and

Page 218 of 715

SSANGYONG RODIUS 2012  Service Manual 03-14
(6) Low Pressure System Pressure Test
Inspection procedure ▶
All wirings/connectors and fuel lines should 
be connected and the engine should work 
properly.
Prepare a special tool for low pre

Page 269 of 715

SSANGYONG RODIUS 2012  Service Manual 08-4
2. INSPECTION
Possible Cause Action
Coolant level 
is
too low- Leak from the radiator
- Leak from the coolant auxiliary tank
- Leak from the heater core- Change the radiator
- Change the coolant

Page 276 of 715

SSANGYONG RODIUS 2012  Service Manual 09-4
2. INSPECTION
1) Alternator Output Test
Item How to check DTC set value / Action
Output 
current
B terminal 
current
Rotor 
coil 
resistance
D terminal 
voltage 
Disconnect the cable connected to
Page:   1-8 9-16 17-24 next >