DODGE RAM SRT-10 2006  Service Repair Manual Theory of Operation
The Torque Converter Clutch (TCC) Solenoid is used to engage the TCC which improves fuel economy. The Over-
drive Solenoid is used to engage the gear change from third to Overdrive

Page 3564 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual NOTE: The governor pressure should rise above 138 kPa (20 PSI). Shortly after the O/D pressure should
rise above 276 kPa (40 PSI).
Did the pressures act as previously described?
Ye s>>
Go To 4
No>>
Go

Page 3565 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 6.INTERMITTENT WIRING AND CONNECTORS
The conditions necessary to set this DTC are not present at this time.
Use the Freeze Frame Data to help duplicate the conditions in which the DTC originally set.

Page 3567 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
Continuously with the ignition on and engine running.
Set Condition:
The Transmission governor pressure set point is above a threshold while inparkortheP/Nswitchisindrive
during an eng

Page 3572 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10 volts.
Set Condition:
A shorted condition is detected in the TIPM Transmission Control Output circuit.
Possible Causes
(T16) TRANS

Page 3573 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.CHECK THE (T16) TRANSMISSION CONTROL OUTPUT CIRCUIT FOR AN OPEN
Turn the ignition off to the lock position.
Connect the TIPM C10 harness connector.
Disconnect the Transmission Solenoid harness conne

Page 3575 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10 volts.
Set Condition:
A shorted condition is detected in the TIPM Transmission Control Output circuit.
Possible Causes
(T16) TRANS

Page 3578 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10 volts.
Set Condition:
An open condition is detected in the TIPM on the Transmission Control Output circuit.
Possible Causes
(T16)