2002 LAND ROVER DISCOVERY Workshop Manual

Page 1377 of 1672

LAND ROVER DISCOVERY 2002  Workshop Manual AIR CONDITIONING
82-4DESCRIPTION AND OPERATION
Refrigerant system
Schematic of air conditioning system
1Evaporator
2Thermostatic expansion valve
3Low pressure servicing connection
4Outlet to rear A/C

Page 1378 of 1672

LAND ROVER DISCOVERY 2002  Workshop Manual AIR CONDITIONING
DESCRIPTION AND OPERATION 82-5
To accomplish the transfer of heat, the refrigerant is circulated around the system, where it passes through two 
pressure/temperature regimes. In each

Page 1379 of 1672

LAND ROVER DISCOVERY 2002  Workshop Manual AIR CONDITIONING
82-6DESCRIPTION AND OPERATION
Condenser
1Condenser matrix
2Outlet connection
3Inlet connection
The condenser transfers heat from the refrigerant to the surrounding air.
The condenser

Page 1380 of 1672

LAND ROVER DISCOVERY 2002  Workshop Manual AIR CONDITIONING
DESCRIPTION AND OPERATION 82-7
Receiver drier
1Dual pressure switch
2Inlet connection
3Housing
4Outlet connection
5Outlet tube
6Screen
7Desiccant
The receiver drier removes moisture a

Page 1381 of 1672

LAND ROVER DISCOVERY 2002  Workshop Manual AIR CONDITIONING
82-8DESCRIPTION AND OPERATION
Thermostatic expansion valve
Thermostatic expansion valve and evaporator
1Refrigerant outlet
2Refrigerant inlet
3Thermostatic expansion valve
4Evaporator

Page 1382 of 1672

LAND ROVER DISCOVERY 2002  Workshop Manual AIR CONDITIONING
DESCRIPTION AND OPERATION 82-9
Evaporator
The evaporator is installed in the air inlet of the heater assembly and absorbs heat from the exterior or recirculated 
inlet air. Low pressu

Page 1383 of 1672

LAND ROVER DISCOVERY 2002  Workshop Manual AIR CONDITIONING
82-10DESCRIPTION AND OPERATION
Heater assembly
1Distribution servo motor
2Refrigerant inlet and outlet connector block
3RH blend flap servo motor
4Thermostatic expansion valve
5LH ble

Page 1384 of 1672

LAND ROVER DISCOVERY 2002  Workshop Manual AIR CONDITIONING
DESCRIPTION AND OPERATION 82-11
Temperature and distribution control
Figure shows flaps set for medium heat to face level and footwell outlets
1Windscreen/Side windows outlet
2Heater