Page 2526 of 4323

I08311
2
1
I28970
Resistance (kW)
Temperature
4.0
2.0 3.5
1.5
0.0
10 3.0
1.0 2.5
0.5
20 30 40 5060
68 86 104 122140
(C)
(F) 50
DI±2324
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2518 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check ambient temperature sensor.
PREPARATION:
Disconnect the ambient temperature sensor connector.
CHECK:
Measure the resistance between terminals 1 and 2 of the ambi-
ent temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±210C (50F)3.00 to 3.73 kW
1±215C (59F)2.45 to 2.88 kW
1±220C (68F)1.95 to 2.30 kW
1±225C (77F)1.60 to 1.80 kW
1±230C (86F)1.28 to 1.47 kW
1±235C (95F)1.00 to 1.22 kW
1±240C (104F)0.80 to 1.00 kW
1±245C (113F)0.65 to 0.85 kW
1±250C (122F)0.50 to 0.70 kW
1±255C (131F)0.44 to 0.60 kW
1±260C (140F)0.36 to 0.50 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace ambient temperature sensor.
OK
3 Check harness and connector between ambient temperature sensor and integra-
tion control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2527 of 4323
I28833
A13
A/C Evaporator
Temp. Sensor
(Front)
12
2 Integration Control and Panel
TE
SG±TE W±GG±B4
I20
I20
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2325
2519 Author: Date:
2005 SEQUOIA (RM1146U)
DTC 13 Front Evaporator Temperature Sensor Cir-
cuit
CIRCUIT DESCRIPTION
This sensor detects the temperature inside the cooling unit and sends the appropriate signals to the integra-
tion control and panel.
DTC No.Detection ItemTrouble Area
13Open or short in front evaporator temperature sensor circuit.
Front evaporator temp. sensor
Harness or connector between front evaporator temp. sensor
and integration control and panel
Integration control and panel
WIRING DIAGRAM
DIDKV±01
Page 2529 of 4323

N16207
Thermometer
Ice
More than
10 cm (3.94in.)1
2
I28971Temperature Resistance (kW)
9.0 10.0
8.0
5.07.0
4.0
2.0 3.0
0.0
14 32 50 68 86 ±10 0 10 20 30
(F) (C) 6.0
1.0
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2327
2521 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check front evaporator temperature sensor.
PREPARATION:
Remove the front evaporator temperature sensor.
CHECK:
Measure the resistance between terminals 1 and 2 of the evap-
orator temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±2±10C (14F)7.40 to 9.20 kW
1±2±5C (23F)5.65 to 7.00 kW
1±20C (32F)4.35 to 5.40 kW
1±25C (41F)3.40 to 4.20 kW
1±210C (50F)2.68 to 3.30 kW
1±215C (59F)2.10 to 2.60 kW
1±220C (68F)1.66 to 2.10 kW
1±225C (77F)1.32 to 1.66 kW
1±230C (86F)1.05 to 1.35 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace front evaporator temperature sensor.
OK
3 Check harness and connector between front evaporator temperature sensor and
integration control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2530 of 4323
I08286
E2
Engine Coolant
Temp. Sensor
1 2Integration Control and Panel
I22 E821
28
E8E2 THWECM
THWO
E5 14
W±R2 G±Y
G±WTW DI±2328
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2522 Author: Date:
2005 SEQUOIA (RM1146U)
DTC 14 Engine Coolant Temperature Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the engine coolant temperature and sends the appropriate signals to the integration
control and panel. These signals are used for warm up control when the engine is cold.
DTC No.Detection ItemTrouble Area
14Open or short in engine coolant temperature sensor circuit.
Engine coolant temp. sensor
Harness or connector between engine coolant temp. sensor
and ECM
Harness or connector between ECM and integration control
and panel
ECM
Integration control and panel
WIRING DIAGRAM
DI935±03
Page 2532 of 4323
I15861
Integration Control and Panel
A29
A/C Evaporator Temp.
Sensor (Rear)I21
RrTE 17
LG±R
BH18
1
2
1
L±R
L±R10
RrSG 18
IJ3
6 LG±R
BH1 LG±R w/ Rear A/C:
L±R
IJ3
I21 DI±2330
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2524 Author: Date:
2005 SEQUOIA (RM1146U)
DTC 17 Rear Evaporator Temperature Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the rear evaporator temperature and sends the appropriate signals to the integration
control and panel.
DTC No.Detection ItemTrouble Area
17Open or short in rear evaporator temperature sensor circuit.
Rear evaporator temp. sensor
Harness or connector between rear evaporator temp. sensor
and integration control and panel
Integration control and panel
WIRING DIAGRAM
DIDKW±01
Page 2534 of 4323

N16207
Thermometer
Ice
More than
10 cm (3.94in.)1
2
I28971Temperature Resistance (kW)
9.0 10.0
8.0
5.07.0
4.0
2.0 3.0
0.0
14 32 50 68 86 ±10 0 10 20 30
(F) (C) 6.0
1.0
DI±2332
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2526 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check rear evaporator temperature sensor.
PREPARATION:
Remove the rear evaporator temperature sensor (See page
AC±42).
CHECK:
Measure the resistance between terminals 1 and 2 of the evap-
orator temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±2±10C (14F)7.40 to 9.20 kW
1±2±5C (23F)5.65 to 7.00 kW
1±20C (32F)4.35 to 5.40 kW
1±25C (41F)3.40 to 4.20 kW
1±210C (50F)2.68 to 3.30 kW
1±215C (59F)2.10 to 2.60 kW
1±220C (68F)1.66 to 2.10 kW
1±225C (77F)1.32 to 1.66 kW
1±230C (86F)1.05 to 1.35 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace rear evaporator temperature sensor.
OK
3 Check harness and connector between rear evaporator temperature sensor and
integration control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2535 of 4323
I24455
A31
A/C Room Temp.
Sensor (Rear)
2
SG±RrTRRrTR Integration Control and Panel
14 13
I22
I22 GR±R B
1 w/ Rear A/C:
GR±R
R±Y R±YJ31
E J32F
AJ/C
J31 J32
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2333
2527 Author: Date:
2005 SEQUOIA (RM1146U)
DTC 19 Rear Room Temperature Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the temperature inside the cabin and sends the appropriate signals to the integration
control and panel.
DTC No.Detection ItemTrouble Area
19Open or short in rear room temperature sensor circuit.
Rear room temp. sensor
Harness or connector between rear room temp. sensor and
integration control and panel
Integration control and panel
WIRING DIAGRAM
DIDKX±01
Page 2537 of 4323

I08309
21
I28970
Resistance (kW)
Temperature
4.0
2.0 3.5
1.5
0.0
10 3.0
1.0 2.5
0.5
20 30 40 5060
68 86 104 122140
(C)
(F) 50
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2335
2529 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check rear room temperature sensor.
PREPARATION:
Disconnect the rear room temperature sensor connector.
CHECK:
Measure the resistance between terminals 1 and 2 of the room
temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±210C (50F)3.00 to 3.73 kW
1±215C (59F)2.45 to 2.88 kW
1±220C (68F)1.95 to 2.30 kW
1±225C (77F)1.60 to 1.80 kW
1±230C (86F)1.28 to 1.47 kW
1±235C (95F)1.00 to 1.22 kW
1±240C (104F)0.80 to 1.00 kW
1±245C (113F)0.65 to 0.85 kW
1±250C (122F)0.50 to 0.70 kW
1±255C (131F)0.44 to 0.60 kW
1±260C (140F)0.36 to 0.50 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace rear room temperature sensor.
OK
3 Check harness and connector between rear room temperature sensor and in-
tegration control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.