1994 JEEP CHEROKEE brakes

[x] Cancel search: brakes

Page 208 of 1784

JEEP CHEROKEE 1994  Service Repair Manual (5) Install lever cover. Secure cover with new riv-
ets, or original attaching screws.
(6) Raise vehicle.
(7) Connect tensioner to lever with retaining pin
and E-clip.
(8) Install nuts attaching lever

Page 209 of 1784

JEEP CHEROKEE 1994  Service Repair Manual (2) Position pedal assembly on panel and install
mounting stud nuts and pedal-to-dash bolt.
(3) Install ground wire on upper end of pedal-to-
dash bolt and secure wire with attaching nut.
(4) Connect

Page 210 of 1784

JEEP CHEROKEE 1994  Service Repair Manual (12) Raise the vehicle.
(13) Install cable-to-frame retaining clip.
(14) Insert cable in equalizer and install equalizer
washer and nuts.
(15) Adjust parking brakes as described in Service
Adjustment

Page 211 of 1784

JEEP CHEROKEE 1994  Service Repair Manual (6) Lower vehicle enough for access to parking
brake lever or foot pedal.Then fully apply parking
brakes. Leave brakes applied until adjustment is
complete.
(7) Raise vehicle again.
(8) Mark tensioner

Page 238 of 1784

JEEP CHEROKEE 1994  Service Repair Manual ERASING TROUBLE CODES
After the problem has been repaired, the DRB scan
tool must be used to erase a DTC. Refer to the ap-
propriate Powertrain Diagnostic Procedures service
manual for operation of th

Page 351 of 1784

JEEP CHEROKEE 1994  Service Repair Manual (3) Connect a jumper between terminal A and B on
the body half of the fuel gauge sender connector. The
gauge should move to F. If gauge is OK, replace
sender. If not, go to step 4.
(4) Measure resista

Page 363 of 1784

JEEP CHEROKEE 1994  Service Repair Manual DIAGNOSINGÐALL LAMPS OUT
(1) Inspect fuse #9. Replace as required.
(2) Measure voltage at instrument cluster connec-
tor terminal 20. Meter should read zero ohms. If not,
repair open to ground.
UPSHI

Page 396 of 1784

JEEP CHEROKEE 1994  Service Repair Manual perform the speed control switch test. If switch is not
at fault, then check main harness and repair as nec-
essary.
(8) Using an ohmmeter, connect one lead to a good
body ground and touch other lead